Optical quality comparison between 2 collagen copolymer posterior chamber phakic intraocular lens designs
2014
Purpose To compare the optical quality in vitro of 2 designs of the Visian Implantable Collamer Lens phakic intraocular lens (pIOL) for different powers and optical apertures. Setting University of Valencia, Valencia, Spain. Design Experimental study. Methods The Nimo TR1504 deflectometry device was used to measure the V4c pIOL, which has a smaller optic diameter, and the V5 pIOL, which has a larger optic diameter. The pIOLs were measured for −3.00 diopters (D), −6.00 D, −9.50 D, and −10.50 D at different optical apertures from 3.00 to 6.00 mm depending on the IOL power and model. The root mean square of higher-order aberrations (RMS HOAs) was analyzed. The Strehl ratio, point-spread functi…
In vitro optical performance of nonrotational symmetric and refractive-diffractive aspheric multifocal intraocular lenses: impact of tilt and decentr…
2012
Purpose To evaluate the optical quality of Acrysof Restor SN6AD1 refractive–diffractive +3.00 D and Lentis Mplus LS-312 nonrotational symmetric +3.00 D aspheric multifocal intraocular lenses (IOLs) and analyze the effect of tilt and decentration. Setting University of Valencia, Valencia, and University of Murcia, Murcia, Spain. Design Experimental study. Methods An artificial model eye was used to measure wavefront aberrations of both IOL models. The modulation transfer function (MTF) and point-spread function (PSF) were calculated for a 5.0 mm pupil and under 5 situations: centered, 0.2 mm and 0.4 mm decentered, and 2 degrees and 4 degrees tilted. Results The refractive–diffractive IOL had…
Biological and technical complications of tilted implants in comparison with straight implants supporting fixed dental prostheses. A systematic revie…
2018
OBJECTIVES To evaluate the implant failure, marginal bone loss (MBL), and other biological or technical complications of restorations supported by tilted and straight implants after at least 3 years in function. METHODS Electronic and manual searches were performed in MEDLINE, Embase, Web of Science, and OpenGrey to identify clinical studies published up to December 2017. After duplicate study selection and data extraction, the risk of bias was assessed with the ROBINS-I tool. Random-effects meta-analyses of relative risks (RRs) or mean differences (MD) and their 95% confidence intervals (CIs) were performed, followed by subgroup/sensitivity analyses and application of the GRADE approach. R…
Effect of thermocycling with or without 1 year of water storage on retentive strengths of luting cements for zirconia crowns
2015
Abstract Statement of problem Bond stability between zirconia crowns and luting cement and between cement and dentin is a main concern; however, only limited evidence is available as to its longevity. Purpose The purpose of this in vitro study was to measure the retentive strengths of 7 self-adhesive cements (RelyX Unicem Aplicap, RelyX Unicem Clicker, RelyX Unicem 2 Automix, iCEM, Maxcem Elite, Bifix SE, SpeedCem), 2 adhesive cements with self-etch primers (Panavia 21, SEcure), 1 glass ionomer cement (Ketac Cem), 1 resin-modified glass ionomer cement (Meron Plus), and 1 zinc phosphate cement for luting zirconia crowns (LAVA) to extracted teeth after thermocycling with or without 1 year of …
Dispositif virtuel d'aide à la chirurgie de l'épaule
2008
The goal of this research is to design a virtual reality prototype to assit an orthopedic surgeon during the replacement of the glenohumeral joint by prosthesis. This system aims to optimize the movements of prosthesized shoulder joint from a choice of various scenarios of pose. These works encompasses several topics such as : orthopedic surgery, image analysis, computer graphics and virtual reality. The chosen process includes a phase of modelling of the bony part of the articulation by simple geometric forms, this model is parameterized from radios or CT scans ; a phase of simulation of the movements of healthy glenohumeral joint ; nally the phase of simulation of cutting and drilling wit…
Ca-P-O thin film preparation, modification and characterisation
2011
Bioceramics are biocompatible ceramic materials, that interact with biological systems of the body to treat, strengthen or replace body functions. Most conventional bioceramics are oxide ceramics, glass ceramics and calcium phosphate ceramics. Among these calcium phosphates, synthetic hydroxyapatite has been extensively studied due to its biomimetic properties similar to that of natural bone. One approach to prepare synthetic hydroxyapatite is to first deposit amorphous Ca-P-O thin film and then by means of post deposition annealing initiate the formation of hydroxyapatite crystals to the film. In addition to the correct film composition and crystalline structure, other surface properties s…
Internal oblique line implants in severe mandibular atrophies
2020
Background Maxillary atrophy may be related to mechanical, inflammatory or systemic factors, being a consequence of a reduction in the amount and quality of available bone. Several surgical techniques have been developed for the restoration of bone volume needed for placing dental implants; guided bone regeneration or three-dimensional reconstructions with autologous bone, inter alia, are techniques described in the literature which demonstrate this, all of which preceded by a proper prosthetic surgical assessment. Even when the majority of authors recommend the use of these techniques prior to placing implants, it has been shown that implants with a smaller diameter and length may be place…
Satisfaction of patients fitted with implant-retained overdentures
2011
Objective: to evaluate patient satisfaction with implant-retained overdentures, and its relationship with age, sex, period of follow-up, the rehabilitated jaw (maxilla, mandible or both), number of implants, splinting, type of attachment and the antagonist.Material and methods: the study comprised patients with overdentures fitted between January 1996 and June 2007, and with a minimum follow-up of one year. Data regarding patients and prostheses were collected. The patients indicated their overall satisfaction on a visual analogue scale (VAS) from 0 to 10, as well as satisfaction for individual items such as aesthetics, speech, mastication, prosthetic stability and selfesteem. These data we…
Necrosis of the long process of the incus following stapes surgery: new anatomical observations.
2009
Objectives/Hypothesis: The most frequent complication (generally recognized during revision procedures) following seemingly successful stapedotomies and stapedectomies is necrosis of the long process of the incus. This is currently ascribed to a malcrimped stapes prosthesis or to a compromised blood supply of the incus. The two-point fixation can cause a mucosal injury with a resulting toxic reaction, and also osteoclastic activity. An important aspect in the engineering of ideal stapes prostheses is that they should be fixed circularly to the long process of the incus with appropriate strength. The objective of this study was to compare current knowledge relating to the blood supply of the…
Survival of implants placed with the osteotome technique : an update. Review
2012
A literature review is made to analyze the survival of implants placed with the osteotome technique. A PubMed search was made based on the key words “osteotome AND dental implants”, corresponding to publications between 1998-2008. The inclusion criteria were: a) a minimum of 10 patients; b) a minimum follow-up of 6 months; c) implants placed using the osteotome technique with or without indirect sinus lift; and d) specification of the implant number and survival rate. Sixty-four articles were identified, of which 20 met the inclusion criteria. A total of 2006 implants were placed in 1312 patients using the osteotome technique. The duration of follow-up after prosthetic loading ranged from 6…