Search results for "Prosthesis"
showing 10 items of 719 documents
Four color-measuring devices compared with a spectrophotometric reference system
2009
Abstract Objectives The objective of this study was to compare the L*C*h° color coordinates of dental color-measuring devices with those of a spectrophotometric reference system. Methods The International Commission on Illumination (CIE) L*C*h° color coordinates of ceramic samples, matching the colors of the VITA Linearguide, were recorded using four color-measuring devices (VITA Easyshade (A), VITA Easyshade compact (B), Degudent Shadepilot (C), X-Rite Shadevision (D)) and a spectrophotometric reference system under standardized test conditions. The intraclass correlation coefficients, regression lines with coefficients of determination, and mean deviations of the dental color-measuring de…
Intubationsnarkosen bei "festsitzenden Zahnprothesen"
2001
Immune Response to Gelatin- and Collagen-Impregnated Aortic Dacron Grafts
1996
Dacron grafts are very common in vascular surgery. Primarily sealed grafts have been available for ten years. These improve handling and reduce intraoperative blood loss. Despite a widespread use all over the world, it has as yet not been clarified whether coating (sealing) substances might cause an immune response, especially in situations of fever or other unexplained events in the postoperative course after graft implantation. In this study, 37 patients with a gelatin-impregnated (Unigraft) and 33 with a collagen-impregnated (Hemashield) graft for aortic or aortoiliac replacement were compared. Serum samples were investigated for collagen antibodies at operation, one week and three mont…
Endovaskuläre Therapie aortaler Aneurysmen: erste klinische Ergebnisse
1996
PURPOSE A clinical study aiming at examining the implantation technique and the clinical results of a new vascular prosthesis in endovascular therapy of aneurysms of the aorta. MATERIAL AND METHODS In 21 patients (20 men of 55 to 87 years of age, average age 70 years) with aneurysms of the infrarenal abdominal aorta (AAA n = 19) and the thoracic aorta (n = 2), a self-expanding nitinol stent with outer Dacron sheath (tubular prosthesis n = 4; bifurcation prosthesis n = 17) was implanted by means of an F-18 introductory set after surgical opening of the inguinal artery. RESULTS By means of the 4 tubular prostheses and 13 of the 17 bifurcation prostheses the aneurysm was bypassed completely. I…
Classification of coronary artery bifurcation lesions and treatments: time for a consensus
2008
Background: Percutaneous coronary intervention (PCI) of coronary bifurcation lesions remains a subject of debate. Many studies have been published in this setting. They are often small scale and display methodological flaws and other shortcomings such as inaccurate designation of lesions, heterogeneity, and inadequate description of techniques implemented. Methods: The aim is to propose a consensus established by the European Bifurcation Club (EBC), on the definition and classification of bifurcation lesions and treatments implemented with the purpose of allowing comparisons between techniques in various anatomical and clinical settings. Results: A bifurcation lesion is a coronary artery na…
Feasibility of a MPR-based 3DTEE guidance protocol for transcatheter direct mitral valve annuloplasty.
2020
Objectives Several interventional approaches have been established for the treatment of severe mitral regurgitation (MR) in patients at elevated risk for surgery. Direct annuloplasty is a relatively novel option in transcatheter mitral valve repair dedicated to reverse pathology in specific subsets of MR. With regard to echocardiographic guidance, this procedure presents with higher efforts in comparison with edge-to-edge therapy to enable safe and exact positioning of the device's anchors; evidence on optimal peri-interventional imaging is sparse. We tested a specific 3D-echo-guidance protocol implementing single-beat multiplanar reconstruction (MPR) and evaluated its feasibility. Methods …
Simulation of left ventricular outflow tract (LVOT) obstruction in transcatheter mitral valve-in-ring replacement.
2020
Left ventricular outflow tract (LVOT) obstruction is a feared complication of transcatheter mitral valve replacement (TMVR). This procedure leads to an elongation of LVOT in the left ventricle (namely, the neoLVOT), ultimately portending hemodynamic impairment and death. This study sought to understand the biomechanical implications of LVOT obstruction in two patients who underwent TMVR as an "off-label" application of the Edwards SAPIEN 3 (S3) Ultra transcatheter heart valve (THV). A computational framework of TMVR was developed to assess the neoLVOT area and quantify the sub-aortic flow structure. We observed that the annuloplasty ring serves as the key anchor zone of S3 Ultra THV. A good…
Minimal Reporting Standards for Active Middle Ear Hearing Implants.
2017
There is currently no standardized method for reporting audiological, surgical and subjective outcome measures in clinical trials with active middle ear implants (AMEIs). It is often difficult to compare studies due to data incompatibility and to perform meta-analyses across different centres is almost impossible. A committee of ENT and audiological experts from Germany, Austria and Switzerland decided to address this issue by developing new minimal standards for reporting the outcomes of AMEI clinical trials. The consensus presented here aims to provide a recommendation to enable better inter-study comparability.
Implants in patients with oral manifestations of autoimmune or muco-cutaneous diseases – A systematic review
2018
Background To give an overview on implant survival rates in patients with oral manifestations of systemic autoimmune (oral Lichen planus (oLp), Pemphigus (Pe)), muco-cutaneous (Epidermolysis bullosa (EB)), autoimmune multisystemic rheumatic diseases (Sjögren´s syndrome (SjS), systemic Lupus erythematosus (sLE), or systemic Sclerosis (sSc)). Material and Methods Systematic literature review (PubMed/Medline, Embase) using MESH and search term combinations, published between 1980 and August 2018 in English language reporting on dental implant-prosthetic rehabilitation of patients with oLp, Pe, EB, SjS, sLE, sSc, study design, age, gender, follow-up period (≥ 12 months), implant survival rate. …
Tightness of duraplasty in rabbits: a comparative study.
2000
OBJECTIVE: The purpose of this study was to test, in rabbits, the tightness of seven dural substitution materials commonly used in neurosurgery, i.e., Lyodura (B. Braun Melsungen AG, Melsungen, Germany), Tutoplast dura (Tutogen Medical, Inc., Parsippany, NJ), Tutoplast fascia lata (Tutogen Medical, Inc.), autologous periosteum, Neuropatch (B. Braun Melsungen AG), Dacron (E.I. du Pont de Nemours and Co., Wilmington, DE), and Ethisorb (Ethicon, Inc., Somerville, NJ). METHODS: Duraplasties were performed with sutures alone or were additionally fixed with fibrin glue. Leakage pressures were assessed by infusion of artificial cerebrospinal fluid, containing sodium fluorescein, into the cisterna …