Search results for "Prosthesis"
showing 10 items of 719 documents
Systemic pulsatile pressure in type II endoleaks after stent grafting of experimental abdominal aortic aneurysms.
2003
Purpose: To investigate pressure and maximum rate of rise of systolic pressure (peak dP/dt) in completely excluded aneurysms and endoleaks to determine the hemodynamic impact of endoleaks. Methods: In mongrel dogs (n = 36) experimental aneurysms were created by insertion of a patch (portion of rectus abdominis muscle sheath) into the infrarenal aorta. In group I (n = 18), all aortic branches of the aneurysm were ligated and all aneurysms were completely excluded by stent grafts. Group II (n = 18) consisted of aneurysms with patent aortic side branches that represented sources of endoleaks. One week (n = 12), six weeks (n = 12), and six months (n = 12) after stent grafting, hemodynamic measu…
Successful transcatheter aortic valve-in-valve implantation in a patient having a chronic type A aortic dissection
2017
Der Einsatz der Tumorprothese bei sekundär-neoplastischer Destruktion des proximalen Femurendes
2008
Total hip arthroplasty was performed with PMMA-augmented tumor prostheses in 42 individuals suffering from metastatic destruction of the proximal end of the femur at the Orthopedic University Hospital Mainz from 1980 to 1992. Neoplastic lesions had been triggered by carcinomas of the breast in 25 female patients. 24 of our patients presented with pathologic fractures. In all patients capable of walking preoperatively early mobilization could be attained by total hip arthroplasty. Pain relief was achieved in each patient. Resection of the major trochanter and, partially, of the pelvitrochanteric muscle sleeve entailed luxation of the prosthesis six times in 5 individuals during the first pos…
Consensus statements and clinical recommendations on treatment indications, surgical procedures, prosthetic protocols and complications following All…
2017
Objectives The present consensus report critically evaluates the scientific evidence based on a comprehensive systematic review of the All-On-4 treatment concept, focusing primarily on the treatment indications, surgical procedures and prosthetic protocols, and secondarily on the mechanical and biological complications involved. Material and Methods A systematic review was made in advance of the meeting. Consensus statements, treatment guidelines and recommendations for future research were based on within-group as well as plenary debates and discussions of the systematic review. Results The main indication of All-On-4 standard care is an atrophic maxilla or mandible, with or without remnan…
Is there still an indication for operative treatment of femoral neck fractures with a ceramic hemiprosthesis?
2000
From 1985 to 1995, 417 patients with dislocated medial femoral neck fractures (Garden III–IV) were treated with hemiarthroplasty using a Biolox ceramic head. The average patient age at the time of operation was 81.5 years. A total of 140 survivors was available for follow-up examination with a mean prosthesis longevity of 55.8 months. The Harris hip score recorded a mean of 70.6 points. At the time of follow up, 5 patients had severe hip pain, and in 8 the roentgenographic examination revealed protrusio acetabuli. Five of these 8 patients underwent revision surgery for replacement of the cup, leaving the stem in situ.
Langzeitergebnisse nach Versorgung medialer Schenkelhalsfrakturen mit Keramikkopfendoprothesen
1996
Total hip replacement is often recommended for the treatment of femoral neck fractures in elderly patients. A less invasive approach with shorter operating time is the replacement of the femoral head only, leaving the acetabular cartilage in situ. Hemiarthroplastic hip replacement using a metallic head prosthesis was not successful in the past, because the majority of patients developed protrusio acetabuli after surgery. In the present study hemiarthroplastic hip replacement using an Al2O3-ceramic head was shown to be a useful method for the treatment of femoral neck fractures in elderly patients. From 1985 to 1990 277 patients were treated with hemiarthroplasty. The average age at the time…
Pulsed radiofrequency energy device (PEAK plasmablade™) and CustomBone® Cranioplasty: an appealing surgical rendez-vous
2019
Background: CustomBone® prosthesis is a widely recognized effective and successful technique for the reconstruction of cranial bone defects. Prior the cranioplasty implant, meticulous dissection wi...
Migration of a Fractured Acetabular Socket Wire Into the Femoral Vein: Indication for Urgent Removal by Venous Thrombectomy: A Case Report
1990
The migration of a foreign body into a great vein is a rare occurrence that requires urgent surgical intervention. In our patient one fragment of a circular acetabular socket wire marker had entered the femoral vein. Exact topographic location of the wire was achieved by computerized tomography. Urgent surgery revealed a floating wire within the venous lumen with associated thrombosis.
Postoperative Lens Position Preoperatively Determined by Scheimpflug Photography
1999
The position of the artificial lens has an important influence on refractive power calculation. We compared the position of the crystalline lens with that of the artificial lens after cataract surgery by means of Scheimpflug photography. A difference in position of approximately 0.8 mm in the anterior direction could be determined.
Lens implant selection with absence of capsular support.
2001
If contact lens or spectacle correction is not viable, little debate exists that the secondary placement of an intra-ocular lens (IOL) is the method of choice in the absence of capsular support. The choice of IOL mainly depends on the preoperative status of the eye (eg, aphakia in children) and the selected location for the implant. Theoretically, there are several IOL implantation approaches in cases without capsular support: an angle-supported anterior chamber (AC) IOL, an iris-fixated ACIOL, an iris-sutured or iris-fixated posterior chamber (PC) IOL and a transsclerally sutured PCIOL. No consensus exists, however, on the indications as well as on the relative safety and efficacy of these…