Search results for "Prosthesis"

showing 10 items of 719 documents

Influence of the prosthetic arm length (palatal position) of zygomatic implants upon patient satisfaction

2016

Background: To assess the influence of the prosthetic arm length (palatal position) of zygomatic implants upon patient comfort and stability, speech, functionality and overall satisfaction. Material and Methods: A retrospective clinical study was made of patients subjected to rehabilitation of atrophic maxilla with complete maxillary implant-supported fixed prostheses involving a minimum of two zygomatic implants (one on each side) in conjunction with premaxillary implants, and with 12 months of follow-up after implant loading. Subjects used a VAS to score general satisfaction, comfort and stability, speech and functionality, and the results were analyzed in relation to the prosthetic arm l…

medicine.medical_treatmentDentistryOdontologíaRetrospective data03 medical and health sciences0302 clinical medicinePatient satisfactionGeneral satisfactionMaxillaAtrophic maxillaHumansJaw EdentulousMedicine030212 general & internal medicineImplant loadingGeneral DentistryRetrospective StudiesPatient comfortDental ImplantsZygomaRehabilitationbusiness.industryResearchDental Implantation Endosseous030206 dentistry:CIENCIAS MÉDICAS [UNESCO]Ciencias de la saludTreatment OutcomeOtorhinolaryngologyPatient SatisfactionMaxillaUNESCO::CIENCIAS MÉDICASSurgeryDental Prosthesis Implant-SupportedOral SurgerybusinessFollow-Up Studies
researchProduct

Clinical retrospective study of dental implant removal : do patients who require implant removal desire implant prosthesis again?

2020

Background This study investigated the causes of dental implant removal due to complications, and examined whether patients who had dental implant removal desired re-implant prosthesis treatments. Material and Methods A retrospective case–control study was conducted on patients who had their dental implants removed. We investigated whether the removed dental implant was replaced with other implant prostheses. Age, sex, diabetes, smoking, implant site distribution, reason for implant removal, and blade and root-form implants were categorized as predictive variables. The outcome variable was desire for re-implantation or use of other prosthetic methods after implant removal. A logistic regres…

medicine.medical_treatmentDentistryProsthesisImplant removalOutcome variablemedicineHumansDental Restoration FailureDental implantGeneral DentistryRetrospective StudiesDental ImplantsImplant prosthesisbusiness.industryResearchDental Implantation EndosseousRetrospective cohort study:CIENCIAS MÉDICAS [UNESCO]OtorhinolaryngologyDental Prosthesis DesignCase-Control StudiesUNESCO::CIENCIAS MÉDICASSurgeryImplantDental Prosthesis Implant-SupportedPredictive variablesbusinessImplantologyFollow-Up Studies
researchProduct

New intraocular lens for achromatizing the human eye.

2007

To describe the design of a new intraocular lens (IOL) capable of correcting spherical and chromatic aberrations when implanted in the human eye.University of Murcia, Murcia, and University of Valencia, Valencia, Spain.A hybrid singlet achromatic IOL was designed. The IOL has a combination of a refractive and a diffractive surface, with 1 of the surfaces being aspherical. Optical simulations were used to model the polychromatic modulation transfer function (MTF) in pseudophakic eyes to explain the differences in optical quality afforded by the achromatic IOL. Parameters such as focus shift, optical path difference, through-focus, and robustness to tilt and decentering of achromatic IOLs wer…

medicine.medical_treatmentIntraocular lensEyeProsthesis DesignModels Biologicallaw.inventionOpticslawChromatic aberrationmedicineHumansDioptrePhysicsLenses Intraocularbusiness.industryModels TheoreticalCentrationSensory SystemsOptical qualityOphthalmologymedicine.anatomical_structureTilt (optics)Achromatic lensOptometrySurgeryHuman eyebusinessColor PerceptionJournal of cataract and refractive surgery
researchProduct

Predictability of short implants ( < 10 mm) as a treatment option for the rehabilitation of atrophic maxillae: a systematic review

2016

Background Short implants (< 10 mm) are one of the treatment options available in cases of limited vertical bone. A purpose of this paper is to evaluate the predictability of short implants as an alternative to technically molthough such implants are now widely used, there is controversy regarding their clinical reliability. There complex treatments in patients with atrophic maxillae, based on a systematic review of the literature and the analysis of the implant survival rates, changes in peri-implant bone level, and associated complications. It is postulated that short implants offer clinical results similar to those of longer implants. Material and Methods A Medline-PubMed search was made…

medicine.medical_treatmentMEDLINEDentistryOdontologíaReview03 medical and health sciences0302 clinical medicineMaxillaHumansMedicineDental Restoration Failure030212 general & internal medicineBone levelGeneral DentistryDental ImplantsImplantes dentalesRehabilitationbusiness.industryDental Implantation EndosseousDental prosthesisReproducibility of ResultsTreatment options030206 dentistry:CIENCIAS MÉDICAS [UNESCO]Ciencias de la saludShort implantsOtorhinolaryngologyMaxillaUNESCO::CIENCIAS MÉDICASOdontología restauradoraSurgeryDental Prosthesis Implant-SupportedImplantOral SurgeryAtrophybusiness
researchProduct

Quality assessment of systematic reviews regarding the effectiveness of zygomatic implants: an overview of systematic reviews

2020

Background Oral rehabilitation of atrophic maxillae features high complexity, for which there are several therapeutic modalities reported on scientific literature. Zygomatic implant placement is a viable option that features low morbidity and allows immediate prosthetic loading. The purpose of the present study was to determine the methodological quality of systematic reviews that assessed the effectiveness of zygomatic implants placed in atrophic maxillae. Material and Methods Searches were conducted on Medline via Pubmed, LILACS, Dare Cochrane, Scopus, and Sigle via Open Grey up to June 2019. Results Seven systematic reviews were eligible for Overview and comprised a total of 2313 patient…

medicine.medical_treatmentMEDLINEDentistryScientific literatureReview03 medical and health sciences0302 clinical medicinemedicineMucositisMaxillaHumansJaw EdentulousSinusitisGeneral DentistryDental ImplantsRehabilitationbusiness.industryDental prosthesisDental Implantation Endosseous030206 dentistrymedicine.disease:CIENCIAS MÉDICAS [UNESCO]Maxillary SinusitisSystematic reviewOtorhinolaryngologyMaxillaUNESCO::CIENCIAS MÉDICASSurgeryDental Prosthesis Implant-SupportedbusinessImplantologyFollow-Up StudiesSystematic Reviews as TopicMedicina Oral, Patología Oral y Cirugía Bucal
researchProduct

Group 1 ITI Consensus Report: The influence of implant length and design and medications on clinical and patient-reported outcomes

2018

The following article: Jung, R.E., Al-Nawas, B., Araujo, M., Avila-Ortiz, G., Barter, S., Brodala, N., ... Windisch, P. (2018). Group 1 ITI Consensus Report: The influence of implant length and design and medications on clinical and patient-reported outcomes. Clinical Oral Implants Research, 29(S16), 69-77, can be accessed at https://doi.org/10.1111/clr.13342. This article may be used for non-commercial purposes in accordance with Wiley Terms and Conditions for Use of Self-Archived Versions. Objectives: The aim of Working Group 1 was to address the influence of different local (implant length, diameter, and design) and systemic (medications) factors on clinical, radiographic, and patient‐re…

medicine.medical_treatmentOsteoporosisbiological complicationsDentistryOsteoporosis/complicationsmeta-analysilaw.inventionProton Pump Inhibitors/adverse effects0302 clinical medicineRandomized controlled triallawRadiography DentalDental Restoration FailureDental implanthumans610 Medicine &amp; healthclinical decision-makingdental implantDiphosphonatesnarrow diameter3504 Oral SurgeryJaw Edentulous Partially05 social sciencesDental Implantation EndosseousImplant failuredrugsmall dental implantVDP::Medisinske Fag: 700::Klinisk odontologiske fag: 830failureclinical decision‐makingDiphosphonates/adverse effectsMeta-analysisrandomized controlled trials/dk/atira/pure/sustainabledevelopmentgoals/good_health_and_well_beingepidemiologymedicationOral SurgerySelective Serotonin Reuptake InhibitorsConsensusreview610 Medicine & healthsurvival03 medical and health sciences10068 Clinic of Reconstructive DentistrySDG 3 - Good Health and Well-beingdental implants0502 economics and businessmedicineshort dental implantsHumansbiological complicationPatient Reported Outcome MeasureshumanSurvival ratesmall dental implantsDental Implantsbusiness.industryJaw Edentulous Partially/rehabilitationshort dental implantProton Pump Inhibitors030206 dentistrymedicine.diseaseendosseous implantSurvival AnalysisVDP::Medical disciplines: 700::Clinical dentistry disciplines: 830Dental Prosthesis Designmeta‐analysisRelative riskrandomized controlled trialOsteoporosis050211 marketingImplantSerotonin Uptake Inhibitors/adverse effectsbusinessosteotomySystematic Reviews as Topic
researchProduct

Stability of radial head and neck fractures: a biomechanical study of six fixation constructs with consideration of three locking plates.

2007

Open reduction and internal fixation of radial neck fractures can lead to secondary loss of reduction and nonunion due to insufficient stability. Nevertheless, there are only a few biomechanical studies about the stability achieved by different osteosynthesis constructs.Forty-eight formalin-fixed, human proximal radii were divided into 6 groups according to their bone density (measured by dual-energy x-ray absorptiometry). A 2.7-mm gap osteotomy was performed to simulate an unstable radial neck fracture, which was fixed with 3 nonlocking implants: a 2.4-mm T plate, a 2.4-mm blade plate, and 2.0-mm crossed screws, and 3 locking plates: a 2.0-mm LCP T plate, a 2.0-mm 6x2 grid plate, and a 2.0…

medicine.medical_treatmentTorsion MechanicalOsteotomyProsthesis DesignFracture Fixation InternalCadaverFracture fixationBone plateMaterials TestingmedicineCadaverInternal fixationHumansOrthopedics and Sports MedicineOrthodonticsUniversal testing machineOsteosynthesisbusiness.industryAnatomyRadiographySurgeryImplantStress MechanicalbusinessRadius FracturesBone PlatesThe Journal of hand surgery
researchProduct

The migration of femoral components after total hip replacement surgery: accuracy and precision of software-aided measurements.

2003

To assess the accuracy and precision of a software-aided system to measure migration of femoral components after total hip replacement (THR) on digitised radiographs.Subsidence and varus-valgus tilt of THR stems within the femur were measured on digitised anteroposterior pelvic radiographs. The measuring software (UMA, GEMED, Germany) relies on bony landmarks and comparability parameters of two consecutive radiographs. Its accuracy and precision were calculated by comparing it with the gold standard in migration measurements, radiostereometric analysis (RSA). Radiographs and corresponding RSA measurements were performed in 60 patients (38-69 years) following cementless THR surgery.The UMA s…

musculoskeletal diseasesAdultMaleAccuracy and precisionmedicine.medical_specialtymedicine.medical_treatmentRadiographyArthroplasty Replacement HipProsthesisRadiostereometric AnalysisForeign-Body MigrationmedicineImage Processing Computer-AssistedHumansRadiology Nuclear Medicine and imagingFemurFemurDigital radiographyAgedOrthodonticsReproducibilitybusiness.industryReproducibility of ResultsMiddle Agedmusculoskeletal systemSurgeryProsthesis FailureRadiographic Image EnhancementOrthopedic surgeryFemaleHip ProsthesisbusinessSkeletal radiology
researchProduct

The Retrograde Tibial Nail: presentation and biomechanical evaluation of a new concept in the treatment of distal tibia fractures.

2013

Displaced distal tibia fractures require stable fixation while minimizing secondary damage to the soft tissues by the surgical approach and implants. Antegrade intramedullary nailing has become an alternative to plate osteosynthesis for the treatment of distal metaphyseal fractures over the past two decades. While retrograde intramedullary nailing is a standard procedure in other long bone fractures, only few attempts have been made on retrograde nailing of tibial fractures. The main reasons are difficulties of finding an ideal entry portal and the lack of an ideal implant for retrograde insertion. The Retrograde Tibial Nail (RTN) is a prototype intramedullary implant developed by our group…

musculoskeletal diseasesAdultMalemedicine.medical_specialtymedicine.medical_treatmentLong boneBone NailsOsteotomyProsthesis Designlaw.inventionIntramedullary rodFixation (surgical)lawmedicineHumansTibiaGeneral Environmental ScienceAgedOsteosynthesisbusiness.industryMiddle Agedmusculoskeletal systemSurgeryBiomechanical PhenomenaFracture Fixation IntramedullaryRadiographyTibial Fracturesmedicine.anatomical_structureTreatment OutcomeGeneral Earth and Planetary SciencesFemaleImplantAnklebusinessBone PlatesInjury
researchProduct

A ten-year follow-up of the Reflection cementless acetabular component.

2008

We reviewed the long-term results at ten to 12 years of 118 total hip replacements in 109 patients using a second-generation hemispherical cementless acetabular component (Reflection) designed to address the problem of backside wear. Five patients (five hips) died and six patients (seven hips) were lost to follow-up. The remaining 98 patients (106 hips) had a mean age of 62.9 years (34.0 to 86.2) A rate of revision for aseptic loosening of 0.9%, and predictable results were found with respect to radiological evidence of fixation, lack of pain, walking ability, range of movement and function. One component was revised for aseptic loosening, and of the 101 hips (95.2%) that did not have a rev…

musculoskeletal diseasesAdultmedicine.medical_specialtyAcetabulum; Adult; Aged; Aged 80 and over; Arthroplasty Replacement Hip; Bone Cements; Equipment Failure Analysis; Follow-Up Studies; Hip Joint; Humans; Middle Aged; Osteoarthritis Hip; Prosthesis Design; Prosthesis Failure; Statistics as Topic; Time Factors; Hip ProsthesisTime FactorsArthroplasty Replacement HipStatistics as TopicProsthesis DesignOsteoarthritis HipmedicineHumansOrthopedics and Sports MedicineSurvival analysisPelvisFixation (histology)AgedAged 80 and overbusiness.industryBone CementsAcetabulumMiddle AgedConfidence intervalSurgeryProsthesis FailureEquipment Failure AnalysisReflection acetabular component hipmedicine.anatomical_structureAcetabular componentRadiological weaponCohortOrthopedic surgerySurgeryHip JointHip ProsthesisbusinessFollow-Up StudiesThe Journal of bone and joint surgery. British volume
researchProduct