Search results for "Pulsatile flow"

showing 10 items of 40 documents

Pulsatile versus continuous oxytocin infusion for the oxytocin challenge test.

1994

In a prospective study, 140 patients had an oxytocin challenge test with either a continuous or a pulsed infusion (one minute of infusion in every five minutes). Both infusion regimens had similar success rates in terms of uterine contractions (97.1 vs 98.6%). The potency ratio (pulsed versus continuous infusion) was significant at 2.7 (1.27 to 5.2), which means that more uterine activity was induced with each mU of oxytocin with pulsatile than with continuous administration. The total amount of oxytocin required to obtain three good contractions in 10 minutes was about 40% less with pulsed administration than with continuous infusion, but the test took 40 minutes longer with the pulsed tha…

AdultOxytocin challenge testContinuous infusionPulsatile flowOxytocinDrug Administration ScheduleUterine contractionUterine ContractionPregnancyMedicineHumansInfusions IntravenousInfusion PumpsUterine activityDose-Response Relationship Drugbusiness.industryPotency ratioInfant NewbornObstetrics and GynecologyGeneral MedicineDose–response relationshipOxytocinAnesthesiaPulsatile FlowFemalemedicine.symptombusinessmedicine.drugArchives of gynecology and obstetrics
researchProduct

An In Vitro Phantom Study on the Role of the Bird-Beak Configuration in Endograft Infolding in the Aortic Arch.

2015

Purpose: To assess endograft infolding for excessive bird-beak configurations in the aortic arch in relation to hemodynamic variables by quantifying device displacement and rotation of oversized stent-grafts deployed in a phantom model. Methods: A patient-specific, compliant, phantom pulsatile flow model was reconstructed from a patient who presented with collapse of a Gore TAG thoracic endoprosthesis. Device infolding was measured under different flow and pressure conditions for 3 protrusion extensions (13, 19, and 24 mm) of the bird-beak configuration resulting from 2 TAG endografts with oversizing of 11% and 45%, respectively. Results: The bird-beak configuration with the greatest protr…

Aortic archModels AnatomicRadiology Nuclear Medicine and ImagingTime FactorsFlow modelPulsatile flowEndograftStent-graft oversizingAorta Thoracic030204 cardiovascular system & hematologyRotation0302 clinical medicineForeign-Body MigrationStentThoracic aortaBird-beak configurationmedicine.diagnostic_testEndovascular ProceduresGraft Occlusion VascularModels CardiovascularAnatomyIn vitro experimentProsthesis FailureBlood Vessel ProsthesiTreatment OutcomePulsatile FlowPatient-specific modelStentsCardiology and Cardiovascular MedicineHumanAortographyTime FactorThoracic endovascular aortic repairProsthesis DesignAortographyImaging phantom03 medical and health sciencesBlood Vessel Prosthesis ImplantationBlood vessel prosthesismedicine.arterymedicineHumansDisplacement (orthopedic surgery)HemodynamicEndovascular Procedurebusiness.industryHemodynamicsDisplacementStent-graft infoldingBlood Vessel ProsthesisSurgerybusinessTomography X-Ray Computed030217 neurology & neurosurgeryStent-graft collapseJournal of endovascular therapy : an official journal of the International Society of Endovascular Specialists
researchProduct

Cardiac output following fetoscopic coagulation of major placental vessels in fetal sheep.

2008

Objectives To measure changes in cardiac output (CO) after partial cord occlusion in fetal sheep in order to investigate pathophysiological fetal adaptation mechanisms in a simulated acute placental insufficiency model under standardized conditions, with the aim of finding relevant methods for monitoring human fetuses during stress situations. Methods We used minimally invasive, percutaneous endoscopic techniques to close umbilical vessels in mid-gestational fetal sheep. Placental blood flow was reduced by preferentially closing first arterial and then the concomitant venous umbilical vessels within a short time interval. The investigations were carried out on 11 pregnant ewes at a median g…

Cardiac outputUmbilical VeinsPlacentaHemodynamicsBlood volumePlacental insufficiencyUltrasonography PrenatalUmbilical ArteriesFetusPregnancymedicine.arterymedicineAnimalsRadiology Nuclear Medicine and imagingCardiac OutputSheep DomesticRadiological and Ultrasound Technologybusiness.industryObstetrics and GynecologyUmbilical arteryGeneral MedicineStroke volumemedicine.diseasemedicine.anatomical_structureReproductive MedicineUltrasonography Doppler PulsedAnesthesiaPulsatile FlowFemalebusinessDuctus venosusBlood Flow VelocityBlood vesselUltrasound in obstetricsgynecology : the official journal of the International Society of Ultrasound in Obstetrics and Gynecology
researchProduct

Second trimester uterine arteries pulsatility index is a function of placental pathology and provides insights on stillbirth aetiology: A multicenter…

2022

Introduction: The aim of this study was to investigate the relationships between maternal vascular malperfusions (MVM) and second trimester uterine arteries pulsatility index (UtA-PI) in cases of stillbirth (SB), compared to live-birth (LB) matched controls. Methods: This was a multicentre, observational, matched case-control study performed at five referral maternity centres over a 4-year period including SB and LB control pregnancies at high-risk for preeclampsia (PE) and/or fetal growth restriction (FGR), matched and stratified for UtA-PI MoM quartiles values of the SB cases. Logistic regression was used to assess the rates of each MVM finding, within each increasing MoM quartile subcate…

HematomaPulsatility indexPlacentaObstetrics and GynecologyLogistic regressionMaternal vascular malperfusionStillbirthUltrasonography PrenatalUterine artery Doppler velocimetryUterine ArteryReproductive MedicinePre-EclampsiaInfarctionPregnancyCase-Control StudiesPregnancy Trimester SecondPulsatile FlowHumansFemalePlacental histopathologyLogistic regression; Maternal vascular malperfusion; Placental histopathology; Pulsatility index; Stillbirth; Uterine artery Doppler velocimetryDevelopmental Biology
researchProduct

Transcranial Doppler and Cortical Microcirculation at Increased Intracranial Pressure and during the Cushing Response

1995

The effect of increased intracranial pressure on the flow velocity of the basilar artery was measured with transcranial ultrasonic Doppler in New Zealand White rabbits under alpha-chloralose anesthesia and artificial respiration. Laser Doppler flowmetry served to study changes of the cortical microcirculation. The results confirm a high inverse correlation of the diastolic flow velocity, the pulsatility index, and the resistance index with the cerebral perfusion pressure (CPP). During acute intracranial hypertension, however, these parameters do not show a good correlation with the local cortical blood flow. The absence of a correlation was evident over a wide CPP range down to values of 35…

Intracranial PressureUltrasonography Doppler TranscranialBlood PressureCushing reflexArtificial respirationMicrocirculationEvoked Potentials SomatosensoryLaser-Doppler FlowmetryAnimalsMedicineCerebral perfusion pressureIntracranial pressureCerebral CortexPseudotumor Cerebribusiness.industryMicrocirculationBlood flowLaser Doppler velocimetryTranscranial DopplerCerebrovascular CirculationPulsatile FlowAnesthesiaFemaleVascular ResistanceSurgeryRabbitsNeurology (clinical)businessBlood Flow VelocityNeurosurgery
researchProduct

Automatic or manual arterial path for the ankle-brachial differences pulse wave velocity

2018

Este artículo se encuentra disponible en la página web de la revista en la siguiente URL: https://journals.plos.org/plosone/article?id=10.1371/journal.pone.0206434 An automated method for measuring arterial path length with devices that determine pulse wave velocity (PWV) in peripheral arteries is frequently applied. We aimed to compare arterial path length measurements based on mathematical height-based formulas with those measured manually and to assess whether the ankle-brachial difference (abD-PWV) measured with the VOPITB device is comparable to that obtained by manual measurements. In 245 patients, a metric measuring tape was used to determine the arterial path length from the suprast…

MaleHipertensión.Brachial ArterySuprasternal notchArteriosclerosislcsh:MedicineDistance Measurement030204 cardiovascular system & hematologyVascular MedicineStiffnessPulse - Mensuration - Mathematical models.AutomationLength measurement0302 clinical medicineMedicine and Health SciencesCoronary Heart Disease030212 general & internal medicinelcsh:ScienceMusculoskeletal SystemPulse wave velocityMathematicsMeasurementMultidisciplinaryRitmo cardíaco - Medición - Modelos matemáticos.Enfermedades cardiovasculares - Factores de riesgo.ArteriesMiddle AgedBlood pressure - Measurement - Mathematical models.Femoral ArteryArmsCarotid Arteriesmedicine.anatomical_structureCardiovascular DiseasesPulsatile FlowPhysical SciencesPresión sanguínea - Medición - Modelos matemáticos.LegsEngineering and TechnologyFemaleAnatomyBlood Flow VelocityPulso - Medición - Modelos matemáticos.Research ArticleAutomated methodAdultMaterials ScienceMaterial PropertiesCardiologyEquipmentPulse Wave Analysis03 medical and health sciencesVascular StiffnessPath lengthHypertension.medicineMechanical PropertiesHumansAnkle Brachial IndexMeasurement EquipmentAgedCardiovascular system - Diseases - Risk factors.lcsh:RAnklesBiology and Life SciencesCross-Sectional StudiesSpainBody LimbsPath (graph theory)Cardiovascular AnatomyBlood Vesselslcsh:QAnkleAnkleBiomedical engineeringTape measurePLOS ONE
researchProduct

Bridging Mucosal Vessels Associated with Rhythmically Oscillating Blood Flow in Murine Colitis

2007

Oscillatory blood flow in the microcirculation is generally considered to be the result of cardiopulmonary influences or active vasomotion. In this report, we describe rhythmically oscillating blood flow in the bridging vessels of the mouse colon that appeared to be independent of known biological control mechanisms. Corrosion casting and scanning electron microscopy of the mouse colon demonstrated highly branched bridging vessels that connected the submucosal vessels with the mucosal plexus. Because of similar morphometric characteristics (19 +/- 11 microm vs. 28 +/- 16 microm), bridging arterioles and venules were distinguished by tracking fluorescent nanoparticles through the microcircul…

MalePathologymedicine.medical_specialtyHistologyPulsatile flowInflammationVasomotionMicrocirculationMiceImage Processing Computer-AssistedmedicineAnimalsIntestinal MucosaEcology Evolution Behavior and SystematicsMice Inbred BALB CPlexusChemistryMicrocirculationBlood flowColitisFlow velocityPulsatile FlowMicroscopy Electron ScanningBiophysicsAnatomymedicine.symptomBlood Flow VelocityIntravital microscopyBiotechnologyThe Anatomical Record: Advances in Integrative Anatomy and Evolutionary Biology
researchProduct

Pre and postoperative evaluation of transcranial Doppler pulsatility index of the middle cerebral artery in patients with severe carotid artery steno…

2016

In the management of severe carotid artery stenosis particular importance must be given to the evaluation of the risk of perioperative cerebral ischemic events. Our study analysed the possible relationship between the pre-operative middle cerebral artery Gosling Index, calculated after transcranial Doppler (TCD), and intra-operative stump pressure (SP), in order to identify patients with higher risk of ischemic accidents. Moreover, we studied pre- and post- operative Gosling Index values in association with possible events during follow-up. In a one-year time lapse 47 patients underwent either carotid endoarterectomy (CEA) or carotid artery stenting (CAS) with proximal embolic protection sy…

MalePostoperative CareEndarterectomy CarotidMiddle Cerebral ArteryUltrasonography Doppler TranscranialDopplerTranscranialcarotid artery stenosisSettore MED/22 - Chirurgia VascolareSeverity of Illness IndexTranscranial; Doppler; middle cerebral artery; carotid artery stenosisPulsatile FlowPreoperative CareHumansCarotid StenosisFemaleProspective Studies
researchProduct

Compliance and Pulse Wave Velocity Assessed by MRI Detect Early Aortic Impairment in Young Patients With Mutation of the Smooth Muscle Myosin Heavy C…

2008

Purpose To evaluate aortic elasticity with MRI on young asymptomatic individuals with mutation of the smooth muscle myosin heavy chain in whom aortic enlargement is not present. Materials and Methods Aortic compliance, aortic distensibility, and pulse wave velocity (PWV) were semiautomatically measured from MRI in 8 asymptomatic subjects having a mutation of the MYH11 gene (M+) and 21 nonmutated relatives (M−) of similar age, sex, and blood pressure characteristics. Results Despite a similar aortic diameter in both groups, the aortic compliance and distensibility were significantly lower in M+ subjects compared with M− (0.84 ± 0.33 versus 2.03 ± 0.54 mm2/mmHg, 1.18 ± 0.62 10−3 versus 5.11 ±…

MalePulsatile flow030204 cardiovascular system & hematology030218 nuclear medicine & medical imaging0302 clinical medicinemagnetic resonance imaginggeneticsPulse wave velocityComputingMilieux_MISCELLANEOUSmedicine.diagnostic_test[ INFO.INFO-IM ] Computer Science [cs]/Medical ImagingPrognosisPulsatile FlowAortic valve stenosiscardiovascular systemCardiologyElasticity Imaging TechniquesFemalemedicine.symptomAlgorithmsBlood Flow VelocityAdultmedicine.medical_specialtypulse wave velocityAortic Valve InsufficiencySensitivity and SpecificityAsymptomaticYoung Adult03 medical and health sciencesElastic Modulusmedicine.arteryInternal medicineImage Interpretation Computer-Assistedmedicine[INFO.INFO-IM]Computer Science [cs]/Medical ImagingHumansGenetic Predisposition to DiseaseRadiology Nuclear Medicine and imagingAortaMyosin Heavy ChainsReceiver operating characteristicbusiness.industryReproducibility of ResultsMagnetic resonance imagingAortic Valve StenosisImage Enhancementmedicine.diseaseaortaBlood pressureMutationelasticitybusiness
researchProduct

Blood pressure and obesity exert independent influences on pulse wave velocity in youth.

2012

The objective was to analyze pulse wave velocity (PWV) in normotensive, high-normal, and hypertensive youths by using aortic-derived parameters from peripheral recordings. The impact of obesity on vascular phenotypes was also analyzed. A total of 501 whites from 8 to 18 years of age were included. The subjects were divided according to BP criteria: 424 (85%) were normotensive, 56 (11%) high-normal, and 21 (4%) hypertensive. Obesity was present in 284 (56%) and overweight in 138 (28%). Pulse wave analysis using a SphygmoCor device was performed to determine central blood pressure (BP), augmentation index, and measurement of PWV. Among the BP groups, differences appeared in age, sex, and hei…

Malemedicine.medical_specialtyAdolescentDiastoleBlood PressureOverweightStandard scoreEssential hypertensionBody Mass IndexInternal medicineInternal MedicineMedicineHumanscardiovascular diseasesObesityChildPulse wave velocitybusiness.industryAge FactorsOverweightmedicine.diseaseObesityBlood pressureEndocrinologyPulsatile FlowHypertensioncardiovascular systemRegression AnalysisFemalemedicine.symptombusinessBody mass indexcirculatory and respiratory physiologyHypertension (Dallas, Tex. : 1979)
researchProduct