Search results for "Pulse duration"
showing 10 items of 54 documents
On the Relationship between Jetted Inks and Printed Biopatterns:Molecular-Thin Functional Microarrays of Glucose Oxidase
2009
Arrays of circular spots of glucose oxidase have been obtained on functionalized silicon oxide by piezoelectric inkjet printing and the enzymatic activity toward glucose recognition has been monitored. The addition of glycerol to the molecular ink allows to obtain high spot definition and resolution (tens of micrometers wide; one molecule tall), but in spite of its well-known structural stabilizing properties, in dynamic conditions it may lead to increased protein stresses. The jetting voltage and pulse length have been found to be critical factors for both activity retention and pattern definition. High voltages and pulse lengths results in stress effects along with the loss of activity, w…
Cavity Ring-Down Spectroscopy measurements of Acetone concentration
2017
This research has been partly supported by the National Research Programme "The next generation of information and communication technologies" (NexIT).
Kilohertz and Low-Frequency Electrical Stimulation With the Same Pulse Duration Have Similar Efficiency for Inducing Isometric Knee Extension Torque …
2017
International audience; Objective To test the hypotheses that, as compared with pulsed current with the same pulse duration, kilohertz frequency alternating current would not differ in terms of evoked-torque production and perceived discomfort, and as a result, it would show the same current efficiency.Design A repeated-measures design with 4 stimuli presented in random order was used to test 25 women: (1) 500-microsecond pulse duration, (2) 250-microsecond pulse duration, (3) 500-microsecond pulse duration and low carrier frequency (1 kHz), (4) 250-microsecond pulse duration and high carrier frequency (4 kHz). Isometric peak torque of quadriceps muscle was measured using an isokinetic dyna…
Long cavity ring fiber mode-locked laser with decreased net value of nonlinear polarization rotation
2019
We investigate a new configuration of a mode-locked fiber laser by using a nonlinear polarization rotation-based design to generate soliton pulses with low repetition rate. Unlike with previously reported configurations, we introduce a Faraday mirror after the first half of the cavity length to counteract the nonlinear polarization rotation effects. The total cavity length is 437 m including a 400-m long twisted SMF-28 fiber. The fiber was twisted to cancel the linear birefringence and to ensure that the polarization ellipticity is not altered as the pulse travels along the fiber. The strict control of polarization yields a stable relation between the polarization state of the pulses propag…
Broadband tuning of a long-cavity all-fiber mode locked Thulium-doped fiber laser using an acousto-optic bandpass filter
2019
A long-cavity passively mode-locked thulium-doped all-fiber laser is reported incorporating a tapered acousto-optic tunable bandpass filter (AOTBF). The operation of the AOTBF relies on the intermodal coupling between core and cladding modes when a flexural acoustic wave propagates along an 80-microm tapered fiber. The filter works in transmission and exhibits a 3-dB bandwidth of 9.02 nm with an insertion loss of 3.4 dB. The laser supports ultrashort pulse generation at a low repetition rate of 784.93 kHz. Optical pulses with 2.43 nm of optical bandwidth and 2.1 ps pulse duration were obtained in a broad tuning range from 1824.77 to 1905.16 nm.
From Above Threshold Ionization to Statistical Electron Emission: The Laser Pulse-Duration Dependence ofC60Photoelectron Spectra
2000
The photoelectron spectra of C60 ionized using a 790 nm laser with pulse durations varying from 25 fs to 5 ps have been determined. For 25 fs pulses, in the absence of fragmentation, the ionization mechanism is direct multiphoton ionization with clear observation of above threshold ionization. As the pulse duration is increased, this becomes dominated by a statistical ionization due to equilibration among the electronic degrees of freedom. For pulse durations on the order of a ps coupling to the vibrational degrees of freedom occurs and the well-known phenomenon of delayed (ms) ionization is observed.
Growth of titanium oxynitride layers by short pulsed Nd:YAG laser treatment of Ti plates: Influence of the cumulated laser fluence.
2009
International audience; Titanium oxynitride layerswere formed by surface laser treatment of Ti plates in air using a Nd:YAG laser source of short pulse duration about 5 ns. The cumulated laser fluence was varied in the 100–1200 J cm2 range and its influence on the composition and the structure of the formed layers was studied by different characterization techniques providing physico-chemical and structural information. It was shown that the laser treatment induces the insertion of light elements as O, N and C in the formed layer with the amount increasing with the laser fluence. The in-depth composition of the layers and the co-existence of different phases were also studied. The way in wh…
The effects of linearly increasing flip angles on 3D inflow MR angiography
1994
As recently demonstrated, spin saturation effects in 3D time-of-flight (TOF) MR angiography (MRA) can be reduced by using RF pulses with linearly increasing flip angles (ramp pulses) in the main direction of flow. We developed a model for calculating the signal distribution of proton flow within the excitation volume (slab) for different ramp slopes and compared the results with the measured distribution for the lower-leg arteries. The ramp pulses were generated using the Fourier transformation of the desired excitation profiles. With a bandwidth of 6 kHz and a pulse length of 2.56 ms satisfactory ramps with variable slopes were generated and applied in a standard flow-compensated 3D FISP s…
Mach-Zehnder interferometer implementation for thermo-optical and Kerr effect study
2018
Scientific Research Project for Students and Young Researchers Nr. SJZ/2016/10; National Research Program “Multifunctional Materials and Composites, Photonics and Nanotechnology” (IMIS2) project “Photonics and materials for photonics”.
Origin of Kerr effect: investigation of solutions by polarization dependent Z-scan
2020
This material is based upon work supported by the ERDF 1.1.1.1 activity project No. 1.1.1.1/16/A/046 “Application assessment of novel organic materials by prototyping of photonic devices”.