Simulated prototype of posterior chamber phakic intraocular lens for presbyopia correction.
2014
Purpose To evaluate the visual impact of adding different spherical aberration values to an Implantable Collamer Lens phakic intraocular lens (pIOL) to increase the depth of focus using an adaptive optics visual simulator. Setting University of Valencia, Valencia, Spain. Design Experimental study. Methods Wavefront aberrations in −3.00 D and −6.00 diopter (D) pIOLs were measured in vitro. Afterward, different simulated pIOL experimental prototypes were created along with variances in the spherical aberration. An adaptive optics visual simulator was used to simulate vision after the implantation of the different pIOL prototypes from their wavefront aberrations. The corrected distance visual …
Dynamic accommodation without feedback does not respond to isolated blur cues
2016
Highlights • A new methodology is used to study a potential cue for dynamic accommodation. • We show that human accommodation is not driven correctly by defocus alone. • Accommodation is most efficient using changes in stimulus vergence with feedback.
Influence of contrast polarity on the accommodative response☆
2018
espanolObjetivo Evaluar los cambios de la respuesta acomodativa del ojo al leer un texto en diferentes condiciones de polaridad de contraste: letras negras sobre fondo blanco (condicion BoW) y letras blancas sobre fondo negro (condicion WoB). Metodos En este estudio experimental participaron dieciocho sujetos de edades comprendidas entre 21 y 41 anos. Se obtuvo objetivamente la respuesta acomodativa (AR) del ojo al leer un texto con polaridad de contraste BoW o WoB con un sistema de optica adaptativa que corregia todas las aberraciones salvo las propias del sujeto. Se estudiaron dos tamanos de letra diferentes (condiciones de agudeza visual), mostrados en una micropantalla. Se midio la AR d…
Curvature of iris profile in spectral domain optical coherence tomography and dependency to refraction, age and pupil size - the MIPH Eye&Health …
2016
Purpose Optical coherence tomography (OCT) of the anterior segment allows quantitative analysis of the geometry of the iris. We performed spectral domain OCT examinations in healthy emmetropic, hyperopic and myopic subjects to investigate iris curvature and its associations. Methods In a cross-sectional study, out of 4617 eyes (2309 subjects) those with refractive errors of +3 dioptres were identified by objective refraction. The iris was examined using the anterior segment mode of a spectral domain 3D OCT-2000 (Topcon Inc., Japan) in the temporal meridian, and OCT scans were investigated with respect to presence and amount of convex and concave iris configuration. Ninety-three eyes of 50 s…
Ocular biometric repeatability using a new high-resolution swept-source optical coherence tomographer.
2020
To assess the repeatability of ocular biometric parameters using a high-resolution imaging device.74 healthy right eyes were included in this study. Five-repeated measurements were taken with ANTERION high-resolution swept-source optical coherence tomographer (SS-OCT) to measure: corneal thickness (central and at 2, 4 and 6-mm diameters), aqueous depth (AD), lens thickness (LT), anterior chamber volume (ACV), axial length (AL), and pupil (diameter and position). The intrasubject standard deviation (SWe have not found statistically significant differences between repeated measurements (p 0.05). The mean difference for corneal thickness was between -0.08 and 0.28 μm. For AD and LT was 0.004 …
Optical factors influencing the amplitude of accommodation
2017
AbstractThe purpose of this work was to find plausible predictors among optical parameters that may explain the inter-individual differences in subjective amplitude of accommodation not explained by age. An exploratory multivariable regression analysis was carried out retrospectively on a dataset with 180 eyes from 97 subjects (ages ranged from 20 to 58years). Subjective amplitudes of accommodation were recorded with the use of a custom-made Badal system. A commercial aberrometer was used to obtain each eye’s wavefront during the full range of accommodation. The plausible predictors under study were pupil diameter in the unaccommodated eye, its reduction with accommodation; fourth- and six-…
The effects of prostaglandin F2α in the human eye
1985
The ocular effects of 200 micrograms of topically applied prostaglandin F2 alpha were studied in 18 nonglaucomatous volunteers. A fall in intraocular pressure was seen in the prostaglandin-treated eyes when compared with the placebo-treated control eyes. The maximum intraocular pressure reduction was observed at the 7th h and hypotensive ocular effect persisted for 24 h. Prostaglandins did not produce any change in pupillary diameter or signs of intraocular inflammation visible by anterior segment biomicroscopy or iris fluorescein angiography. The drug caused side effects: conjunctival hyperemia was constant and many patients complained of ocular smarting and headache. It could be useful in…
Light distortion of soft multifocal contact lenses with different pupil size and shape
2020
Purpose: To study the light distortion effects of soft multifocal contact lenses and the influence of different pupil size and shape.Methods: A total of 14 eyes of 7 healthy contact lens users (mean age 28.6 +/- 8.5 years) were recruited. The "Light Disturbance Analyser" device was employed for light characterization. The selected lenses were the monthly disposable "Biofinity multifocal" (CooperVision, CA, USA), both centre-distance and centre-near designs (addition power + 2.50 D). Two circular pupils of 3 mm and 5 mm of diameter, and an elliptical shape (3 horizontal and 5 vertical mm) were used. Metrics such as the light distortion index (LDI), best-fit circle radius and its irregularity…
Visual quality comparison of conventional and Hole-Visian implantable collamer lens at different degrees of decentering
2013
Purpose To compare the visual quality of implantable collamer lens (ICL) with and without central hole (Hole ICL and conventional ICL) at different degrees of decentering. Methods An adaptive optics visual simulator (crx1, Imagine Eyes, Orsay, France) was used to simulate the –3, –6 and –12 dioptres (D) conventional and Hole ICLs in three conditions: centred and decentred 0.3 and 0.6 mm. Visual acuity (VA) at high-contrast, medium-contrast and low-contrast and contrast sensitivity (CS) were measured in 15 observers for 3 and 4.5 mm pupils. Results No statistically significant differences in VA and CS were found between conventional and Hole ICLs for any ICL powers and pupil sizes evaluated …
Effect of phenylephrine on static and dynamic accommodation
2018
Purpose We tested the hypothesis that changes in accommodation after instillation of Phenylephrine Hydrochloride (PHCl) observed in some studies could be caused by changes in optics. Methods We performed two experiments to test the effects of PHCl on static and on dynamic accommodation in 8 and 6 subjects, respectively. Objective wavefront measurements were recorded of the static accommodation response to a stimulus at different distances or dynamic accommodation response to a sinusoidally moving stimulus (between 1 and 3 D of accommodative demand at 0.2 Hz). The responses were characterized using two methods: one that takes into account the mydriatic optical effects on the accommodation pr…