Search results for "QUARTZ"

showing 10 items of 239 documents

EDXRF and TXRF analysis of elemental size distributions and environmental mobility of airborne particles in the city of Riga, Latvia

2004

Airborne particles were investigated in the central part of Riga during October 2000. Mass, black carbon and elemental concentrations of airborne particles were measured on Teflon filters from a dichotomous impactor, which samples fine (<2.5 µm) and coarse (2.5‐10 µm) fractions of particles. In order to obtain more detailed information on the size distributions of different elements, a seven-stage Batelle cascade impactor was used, in which quartz plates treated with silicone grease were utilized as backing for the different stages. Total reflection x-ray fluorescence (TXRF) and energy-dispersive x-ray fluorescence (EDXRF) spectrometry were used for elemental analysis on the quartz plates a…

ChemistryElemental analysisSoil waterAnalytical chemistryLessivageMineralogyCarbon blackMass spectrometrycomplex mixturesSilicone greaseQuartzSpectroscopyAerosolX-Ray Spectrometry
researchProduct

Structure and luminescence of GaN layers

2001

Abstract GaN films grown on 〈1 1 1〉 Si substrate by means of low pressure MOCVD technique in a horizontal flow quartz reactor are characterized by different thin layer analysis methods. The polycrystalline hexagonal structure of the GaN layers has been checked by means of grazing incidence X-ray diffractometry and IR spectroscopy. Cathodoluminescence (CL) spectra and their time kinetics are studied. The mean decay time of the 3.44 eV UV bound exciton transition is below 1 ns, whereas the 3.26 eV violet band shows a slow hyperbolical decay over about 1 μs. A third yellow band appears at 2.12 eV due to transitions via localized states.

ChemistryExcitonAnalytical chemistryGeneral Physics and AstronomyInfrared spectroscopyCathodoluminescenceSurfaces and InterfacesGeneral ChemistryCrystal structureCondensed Matter PhysicsSurfaces Coatings and FilmsCrystalliteMetalorganic vapour phase epitaxyLuminescenceQuartzApplied Surface Science
researchProduct

Electrosynthesis of Poly(alanine)-Like Peptides in Concentrated Alanine Based Electrolytes, Characterization Coupled to DFT Study and Application to …

2014

The anodic oxidation of concentrated l-alanine on smooth electrodes such as platinum and glassy carbon electrodes was studied. Contrary to the previous studies performed up to now with diluted l-alanine, the electrochemical process generated here results in a completely different situation. The oxidation on smooth platinum was carried out by electrochemical quartz crystal microbalance (EQCM) coupled to cyclic voltammetry technique. The effects of concentration, scan rate, and pH (zwitterion at pH = 6 and alkaline media at pH = 13) on potential values were examined. Glassy carbon and smooth gold electrodes showed the same behavior as on smooth platinum electrode. Spectroscopic analysis such …

ChemistryInorganic chemistrychemistry.chemical_elementInfrared spectroscopyQuartz crystal microbalanceGlassy carbonElectrosynthesisElectrochemistrySurfaces Coatings and FilmsElectronic Optical and Magnetic MaterialsGeneral EnergyAttenuated total reflectionPhysical and Theoretical ChemistryCyclic voltammetryPlatinumThe Journal of Physical Chemistry C
researchProduct

Alternating current electrogravimetry of copper electrodissolution in a sulfuric acid solution

2017

Abstract Copper electrodissolution processes have been studied by means of electrochemical impedance spectroscopy and ac-electrogravimetry (mass impedance). During ac-electrogravimetry acquisition, mass decreases or increases due to the electrodissolution or the electrodeposition of copper, respectively. As a result, this continuous mass drift makes impossible obtaining a true ac-electrogravimetry response unless a numerical correction was applied. It has been compared the electrochemical behavior of copper layers previously treated and other freshly deposited on the gold electrode of the quartz crystal microbalance. The simultaneous analysis of both impedance functions has allowed separati…

ChemistryOpen-circuit voltageGeneral Chemical EngineeringInorganic chemistryAnalytical chemistrychemistry.chemical_element02 engineering and technologyQuartz crystal microbalance010402 general chemistry021001 nanoscience & nanotechnologyElectrochemistry01 natural sciencesCopper0104 chemical sciencesDielectric spectroscopyElectrogravimetryElectrodeElectrochemistry0210 nano-technologyElectrical impedanceElectrochimica Acta
researchProduct

Evaluation of adhesion forces for the manipulation of micro-objects in submerged environment through deposition of pH responsive polyelectrolyte laye…

2016

Optimization of surface treatment for reversible adhesion of micro-objects in liquid environment for the need in microassembly processes is presented. A spherical borosilicate probe and planar oxidized silicon wafer substrates were modified by deposition of pH sensitive polyelectrolyte films through layer-by-layer technique. Branched polyethylenimine (b-PEI) and poly(sodium styrenesulfonate) (PSS) were deposited in alternating manner on surfaces, and the influence of polyelectrolyte concentration, pH of deposition, and number of layers on the adhesion were successively examined. The multilayer buildup was followed by optical reflectometry (OR) and dissipative quartz crystal microbalance (QC…

ChemistrySurface forceNanotechnology02 engineering and technologySurfaces and InterfacesAdhesionQuartz crystal microbalance010402 general chemistry021001 nanoscience & nanotechnologyCondensed Matter Physics01 natural sciences6. Clean waterPolyelectrolyte0104 chemical sciencesContact angleChemical engineeringElectrochemistrySurface roughnessDeposition (phase transition)[CHIM]Chemical SciencesGeneral Materials ScienceWafer0210 nano-technologySpectroscopyComputingMilieux_MISCELLANEOUS
researchProduct

Gas chromatographic separation of acetylated chlorinated phenols, guaiacols and catechols on an SE-30 quartz capillary column

1983

ChromatographyOrganic ChemistryGeneral MedicineBiochemistryAnalytical Chemistrylaw.inventionchemistry.chemical_compoundChromatographic separationchemistryCapillary columnChlorinated phenolslawFlame ionization detectorPhenolsGas chromatographyQuartzJournal of Chromatography A
researchProduct

P-T path development derived from shearband boudin microstructure

2016

This work focuses on the development of a regional P-T-path from the Malpica-Lamego Ductile Shear Zone, NW Portugal, based on the microstructures of shearband boudins evolved during progressive simple shear. The combination of microstructural analysis, fluid inclusion studies, crystallographic pre- ffered orientation and fractal geometry analyses, allows to link several stages in the internal evolution of the boudin to regional P-T conditions. The boudinage process is initiated under differential stress after the original layer achieved sufficient viscosity contrast relative to the surrounding matrix. Two main transformations occur simultaneously: i) change in the external shape with contin…

Ciências Naturais::Ciências da Terra e do Ambiente010504 meteorology & atmospheric sciencesMineralogyQuartz CPO e Fabric AnalyserGeometry010502 geochemistry & geophysics01 natural sciencesBoudinageQuartz microstructure:Ciências da Terra e do Ambiente [Ciências Naturais]0105 earth and related environmental sciencesScience & Technology4. EducationQuartz CPO - Fabric AnalyserGeologyP-T-pathShearband boudinSimple shearStrain partitioningFractal geometryPTVX fluid inclusionShear (geology)Dynamic recrystallizationGrain boundaryShear zoneDifferential stressGeology
researchProduct

Microstructural evolution of gas hydrates in sedimentary matrices observed with synchrotron X-ray computed tomographic microscopy

2015

The formation process of gas hydrates in sedimentary matrices is of crucial importance for the physical and transport properties of the resulting aggregates. This process has never been observed in situ at submicron resolution. Here we report on synchrotron-based microtomographic studies by which the nucleation and growth processes of gas hydrate were observed at 276 K in various sedimentary matrices such as natural quartz (with and without admixtures of montmorillonite type clay) or glass beads with different surface properties, at varying water saturation. Both juvenile water and metastably gas-enriched water obtained from gas hydrate decomposition was used. Xenon gas was employed to enha…

Clathrate hydrateNucleationMineralogychemistry.chemical_elementMicrostructureMicrometrechemistry.chemical_compoundGeophysicsMontmorilloniteXenonchemistryGeochemistry and PetrologySedimentary rockPhysics::Chemical PhysicsQuartzGeologyGeochemistry, Geophysics, Geosystems
researchProduct

EQCM and Quartz Crystal Impedance Measurements for the Characterization of Thiophene-Based Conducting Polymers

1999

AbstractEQCM was extensively used to investigate ion-transport phenomena during dopingundoping processes of electronically conducting polymers. Several early studies assumed that the polymer films were rigidly coupled to the quartz crystal so as to relate the mass change to the quartz crystal resonant frequency change via the Sauerbrey equation. However, the rigidity of electronically conducting polymer films is doubtful and it has to be demonstrated. Quartz crystal impedance analysis near the resonance is of paramount importance to get insight into the viscoelastic properties of the film [1] and to avoid misleading in the interpretation of EQCM data.This contribution presents and discusses…

Conductive polymerCrystalchemistry.chemical_classificationMaterials sciencechemistrySauerbrey equationResonancePolymerComposite materialQuartzElectrical impedanceViscoelasticityMRS Proceedings
researchProduct

Comprehensive Study of Poly(2,3,5,6-tetrafluoroaniline): From Electrosynthesis to Heterojunctions and Ammonia Sensing.

2018

In this work, we report for the first time on a comprehensive study of poly(2,3,5,6-tetrafluoroaniline) (PTFANI). Contrary to the nonfluorinated polyaniline (PANI) or its analogues bearing one fluorine atom, PTFANI is a poorly conductive material. We present a comprehensive study of the electrosynthesized PTFANI from its monomer in an acidic aqueous medium. PTFANI was fully characterized by a potential-pH diagram, spectroelectrochemistry, and electrochemical quartz crystal microbalance (EQCM) measurements, as well as by a morphological study. Combined with the X-ray photoelectron spectroscopy (XPS) analysis, it allowed us to understand the redox properties of this polymer compared to those …

Conductive polymerMaterials scienceInorganic chemistry02 engineering and technologyQuartz crystal microbalance010402 general chemistry021001 nanoscience & nanotechnologyElectrosynthesisElectrochemistry01 natural sciencesRedox0104 chemical scienceschemistry.chemical_compoundElectron transferchemistryX-ray photoelectron spectroscopyPolyaniline[CHIM]Chemical SciencesGeneral Materials Science0210 nano-technologyComputingMilieux_MISCELLANEOUSACS applied materialsinterfaces
researchProduct