Receiving water body quality assessment: an integrated mathematical approach applied to an Italian case study

2011

This study presents a basin-scale approach to the analysis of receiving water body quality considering both point and non-point pollution sources. In particular, this paper describes an extensive data gathering campaign carried out in the Nocella catchment, which is an agricultural and semi-urbanised basin located in Sicily, Italy. Two sewer systems, two wastewater treatment plants and a river reach were monitored during both dry and wet weather periods. A mathematical model of the entire integrated system was also created. Specifically, a detailed modelling approach was developed by employing three well known models: Storm Water Management Model, GPS-X and Soil and Water Assessment Tool. T…

PollutionAtmospheric ScienceSoil and Water Assessment Toolmedia_common.quotation_subjectDrainage basinPoint source pollutionnon-point pollution sourceQuality (business)Civil and Structural EngineeringWater Science and Technologymedia_commongeographygeography.geographical_feature_categorySettore ICAR/03 - Ingegneria Sanitaria-Ambientalebusiness.industryriver water quality monitoringSettore ICAR/02 - Costruzioni Idrauliche E Marittime E IdrologiaEnvironmental engineeringriver water quality modellingStorm Water Management ModelGeotechnical Engineering and Engineering Geologyurban drainage-integrated modellingpoint pollution sourceAgricultureEnvironmental scienceWater qualityWater resource managementbusinessJournal of Hydroinformatics
researchProduct

Emission standards versus immission standards for assessing the impact of urban drainage on ephemeral receiving water bodies

2010

In the past, emission standard indicators have been adopted by environmental regulation authorities in order to preserve the quality of a receiving water body. Such indicators are based on the frequency or magnitude of a polluted discharge that may be continuous or intermittent. In order to properly maintain the quality of receiving waters, the Water Framework Directive, following the basic ideas of British Urban Pollution Manual, has been established. The Directive has overtaken the emission-standard concept, substituting it with the stream-standard concept that fixes discharge limits for each polluting substance depending on the self-depurative characteristics of receiving waters. Stream-…

PollutionConservation of Natural ResourcesTime FactorsEnvironmental EngineeringRainmedia_common.quotation_subjecturban drainage integrated modelling Water Framework Directive water quality management water quality monitoringEnvironmentWaste Disposal FluidDrainage system (geomorphology)Water MovementsCitiesDrainageWater Science and Technologymedia_commonSettore ICAR/03 - Ingegneria Sanitaria-AmbientaleEmission standardSettore ICAR/02 - Costruzioni Idrauliche E Marittime E IdrologiaDrainage SanitaryWater PollutionEnvironmental engineeringWaterModels TheoreticalWastewaterWater Framework DirectiveEnvironmental scienceCombined sewerWater qualityWater resource managementWater Science and Technology
researchProduct

Quantification of diffuse and concentrated pollutant loads at the watershed-scale: an Italian case study

2009

In this study, diffuse and point source pollutant loads were evaluated using an Italian case study: the Nocella catchment, which has been subject to extensive monitoring. The Nocella catchment is located in Sicily (Italy) and has an area of about 60 km2. The river receives wastewater and stormwater from two urban areas drained by combined sewers. The two sewer systems, two wastewater treatment plants and a river reach were monitored during both dry and wet weather periods. Thereafter, an integrated catchment-scale model was applied to simulate point pollutant sources, i.e., pollution coming from the urban drainage system, and nonpoint pollutant sources, i.e., pollution coming from agricultu…

PollutionEnvironmental Engineeringmedia_common.quotation_subjectnonpoint pollution sourcewater quality monitoringStormwaterRiversComputer SimulationSanitary sewerNonpoint source pollutionWater Science and Technologymedia_commonHydrologyPollutantSettore ICAR/03 - Ingegneria Sanitaria-AmbientaleSewageSettore ICAR/02 - Costruzioni Idrauliche E Marittime E IdrologiaModels Theoreticalcatchment-scale integrated modellingpoint pollution sourceItalyWastewaterTotal maximum daily loadEnvironmental scienceWater qualityWater Pollutants ChemicalEnvironmental MonitoringWater Science and Technology
researchProduct

Hydrogen sulfide measurements in air by passive/diffusive samplers and high-frequency analyzer: A critical comparison

2016

In this study, hydrogen sulfide (H2S) measurements in air carried out using (a) passive/diffusive samplers (Radiello® traps) and (b) a high-frequency (60 s) real-time analyzer (Thermo® 450i) were compared in order to evaluate advantages and limitations of the two techniques. Four different sites in urban environments (Florence, Italy) and two volcanic areas characterized by intense degassing of H2S-rich fluids (Campi Flegrei and Vulcano Island, Italy) were selected for such measurements. The concentrations of H2S generally varied over 5 orders of magnitude (from 101e103 mg/m3), the H2S values measured with the Radiello® traps (H2SR) being significantly higher than the average values measure…

PollutionSpectrum analyzerAir quality monitoring010504 meteorology & atmospheric sciencesOrders of magnitude (temperature)media_common.quotation_subjectHydrogen sulfideActive analyzersAnalytical chemistryPassive/diffusive samplers010501 environmental sciencesHydrogen sulphide01 natural sciencesAir quality monitoringchemistry.chemical_compoundGeochemistry and PetrologyEnvironmental Chemistry0105 earth and related environmental sciencesmedia_commongeographygeography.geographical_feature_categoryHydrogen sulfideGaseous contaminantsPollutionPassive/diffusive samplerchemistryVolcanoEnvironmental chemistryGaseous contaminantH2S in airActive analyzerApplied Geochemistry
researchProduct

EVALUATION OF DIFFUSE AND CONCENTRATED POLLUTION AT WATERSHED SCALE

2009

The study presents an integrated approach in order to analyse and quantify pollution dynamics at basin scale depending on concentrated and diffuse sources. More specifically, an integrated model for urban drainage system has been exploited in order to simulate the complex sewer network - wastewater treatment plant and receiving water body. Moreover, a quali-quantitative model has been developped in order to simulate the non-point sources pollutant (agricultural and zoo-technical) in term of water river discharges and nutrient, produced from the wash off of soils. Finally, different models have been coupled in order to reconstruct the whole pollutant load for the receiving water body and to …

Settore ICAR/03 - Ingegneria Sanitaria-AmbientaleSettore ICAR/02 - Costruzioni Idrauliche E Marittime E IdrologiaPoint sources Non-point sources Urban drainage integrated modelling Water quality monitoring
researchProduct

Startup and effects of relative water renewal rate on water quality and growth of rainbow trout (Oncorhynchus mykiss) in a unique RAS research platfo…

2018

Abstract The aquaculture industry is growing fast but facing two major challenges: a shortage of suitable locations for growth and the need to reduce environmental impacts. One solution for both these challenges is inland production through recirculating aquaculture systems (RAS). The RAS technique is rather new, and several practical issues need to be solved. In this study, an experimental platform, consisting of ten individual RAS units, was built for small-scale testing of different RAS designs and operation methods, and two preliminary experiments were conducted. In the first experiment, the capability of different chemical additions (sodium nitrite, ammonium chloride and/or cane sugar)…

UV/VIS spectrometrywater quality monitoringvesinitrifikaatio010501 environmental sciencesAquatic Science01 natural sciencesFeed conversion ratiochemistry.chemical_compoundNitrateAquacultureNitritevesiviljely (kalatalous)0105 earth and related environmental sciencesbusiness.industrylaatu04 agricultural and veterinary sciencesPulp and paper industrynitrificationchemistrydimensioningBiofilter040102 fisheriesta11810401 agriculture forestry and fisheriesEnvironmental scienceresearch facilityNitrificationRainbow troutWater qualitybusinessAquacultural Engineering
researchProduct

New Trends in Urban Drainage Modelling

2019

This book addresses the latest research advances, innovations, and applications in the field of urban drainage and water management as presented by leading researchers, scientists and practitioners from around the world at the 11th International Conference on Urban Drainage Modelling (UDM), held in Palermo, Italy from 23 to 26 September, 2018. The conference was promoted and organized by the University of Palermo, Italy and the International Working Group on Data and Models, with the support of four of the world’s leading organizations in the water sector: the International Water Association (IWA), International Association for Hydro-Environment Engineering and Research (IAHR), Environmenta…

Urban Stormwater Modelling TransportSettore ICAR/03 - Ingegneria Sanitaria-AmbientaleUrban Wastewater Water Quality MonitoringWater Management Urban HydrologyUrban Hydraulic Processes Drainage Engineering
researchProduct

CHOOSING OF OPTIMAL REFERENCE SAMPLES FOR BOREAL LAKE CHLOROPHYLL A CONCENTRATION MODELING USING AERIAL HYPERSPECTRAL DATA

2018

Abstract. Optical remote sensing has potential to overcome the limitations of point estimations of lake water quality by providing spatial and temporal information. In open ocean waters the optical properties are dominated by phytoplankton density, while the relationship between color and the constituents is more complicated in inland waters varying regionally and seasonally. Concerning the difficulties relating to comprehensive modeling of complex inland and coastal waters, the alternative approach is considered in this paper: the raw digital numbers (DN) recorded using aerial remote hyperspectral sensing are used without corrections and derived by means of regression modeling to predict C…

lcsh:Applied optics. Photonics010504 meteorology & atmospheric scienceshyperspectral imagingwater quality monitoringchlorophyll a0211 other engineering and technologies02 engineering and technologylcsh:Technology01 natural sciencesStandard deviationPhytoplanktonPredictabilityCluster analysis021101 geological & geomatics engineering0105 earth and related environmental sciencesRemote sensinglcsh:Tlcsh:TA1501-1820Hyperspectral imagingSampling (statistics)Statistical modelRegression analysislake water coloraerial remote sensinglcsh:TA1-2040Environmental sciencelcsh:Engineering (General). Civil engineering (General)The International Archives of the Photogrammetry, Remote Sensing and Spatial Information Sciences
researchProduct

Decision-Making Tools to Manage the Microbiology of Drinking Water Distribution Systems

2020

[EN] This paper uses a two-fold multi-criteria decision-making (MCDM) approach applied for the first time to the field of microbial management of drinking water distribution systems (DWDS). Specifically, the decision-making trial and evaluation laboratory (DEMATEL) was applied removing the need for reliance on expert judgement, and analysed interdependencies among water quality parameters and microbiological characteristics of DWDS composed of different pipe materials. In addition, the fuzzy technique for order preference by similarity to ideal solution (FTOPSIS) ranked the most common bacteria identified during trials in a DWDS according to their relative abundance while managing vagueness…

lcsh:Hydraulic engineeringComputer sciencemedia_common.quotation_subjectGeography Planning and Developmentwater quality monitoringDEMATEL02 engineering and technology010501 environmental sciencesAquatic Science01 natural sciencesBiochemistryFuzzy logicDistribution systemWater quality monitoringlcsh:Water supply for domestic and industrial purposeslcsh:TC1-9780202 electrical engineering electronic engineering information engineering03.- Garantizar una vida saludable y promover el bienestar para todos y todas en todas las edadesFTOPSISIntegrated management0105 earth and related environmental sciencesWater Science and Technologymedia_commonlcsh:TD201-50006.- Garantizar la disponibilidad y la gestión sostenible del agua y el saneamiento para todosDrinking water distribution systemsIntegrated approachMultiple-criteria decision analysisInterdependenceRisk analysis (engineering)drinking water distribution systemsMicrobiological assessmentMulti-criteria system analysismicrobiological assessment020201 artificial intelligence & image processingWater qualityMATEMATICA APLICADAmulti-criteria system analysisReal world dataWater
researchProduct

Monitoring the quality of the hospital pharmacoterapeutic process by sentinel patient program

2018

To analyze the results of sentinel patient program to monitoring the  quality pharmacoterapeutic process in the hospitalized patient through  medication errors.Design: Observational, prospective and transversal study. Ambit: General hospital of 1,000 beds.From May 2011 to June 2016.  Sample: Patients with treatment prescribe within 24 hours of being admitted  with 4 or more medications.Medication error, drugs prescribed,  medications and doses dispensing, drugs administered. Safety indicators were  defined based on medication errors at each stage of the pharmacotherapeutic  process.Of the 746 patients studied, 334 had at least 1 medication error  (44.8%; IC95%: 41.7-47.8). In the 746 treatm…

lcsh:Rlcsh:Medicinelcsh:RS1-441Safety;Drug PrescriptionsQuality ImprovementDrug Hypersensitivitylcsh:Pharmacy and materia medicaMedication errorsQuality monitoringHumansPatient SafetyProspective StudiesSafetyPharmacy Service HospitalQuality of Health CareFarmacia Hospitalaria