Search results for "R855-855.5"

showing 10 items of 35 documents

Healthy mitochondria for stroke cells.

2018

Stroke is a debilitating disease that remains as a significant unmet need. Although our understanding of the disease pathology has advanced over the years, treatment options for stroke are limited. Recent studies have implicated the important role of healthy mitochondria in neuroprotection against stroke. Under the stroke pathological condition, transfer of healthy mitochondria is observed from astrocytes to ischemic neurons. However, without additional therapeutic intervention, such astrocyte-to-neuron transfer of mitochondria may not sufficiently afford a robust and stable therapeutic effect against the devastating primary insult and progressive neurodegeneration associated with stroke. W…

lcsh:Diseases of the circulatory (Cardiovascular) systemAginglcsh:Medical technologyneuronsReview ArticleDiseaseMitochondrion010402 general chemistryBioinformatics01 natural sciencesNeuroprotectionstem cellsmedicineStrokePathological010405 organic chemistrybusiness.industryNeurosciencesGeneral Medicinemedicine.diseaseStem Cell Researchstrokeneuronendothelial cells0104 chemical sciencesReview articleBrain Disordersstem cellTransplantationmitochondriaStrokelcsh:R855-855.5lcsh:RC666-701AstrocytesNeurologicalendothelial cellStem cellAstrocytebusiness
researchProduct

Diagnostic Accuracy and Usability of the ECG247 Smart Heart Sensor Compared to Conventional Holter Technology

2021

Background. Heart rhythm disorders, especially atrial fibrillation (AF), are increasing global health challenges. Conventional diagnostic tools for assessment of rhythm disorders suffer from limited availability, limited test duration time, and usability challenges. There is also a need for out-of-hospital investigation of arrhythmias. Therefore, the Norwegian ECG247 Smart Heart Sensor has been developed to simplify the assessment of heart rhythm disorders. The current study aimed to evaluate the diagnostic accuracy and usability of the ECG247 Smart Heart Sensor compared to conventional Holter monitors. Methods. Parallel tests with ECG247 Smart Heart Sensor and a Holter monitor were perform…

MaleMedicine (General)TechnologyHolter monitormedicine.medical_specialtyRhythm analysisArticle SubjectHeart rhythm disordersBiomedical EngineeringHealth InformaticsDiagnostic accuracyDiagnostic toolsElectrocardiographyR5-920Heart RateAtrial FibrillationMedical technologymedicineHumansR855-855.5medicine.diagnostic_testbusiness.industryAtrial fibrillationUsabilityMiddle Agedmedicine.diseaseTest durationEmergency medicineElectrocardiography AmbulatoryFemaleSurgerybusinessResearch ArticleBiotechnologyJournal of Healthcare Engineering
researchProduct

Time of flight for photon in human skin

2016

The time of flight for photons in human skin was measured using picosecond diode laser. Two different wavelength lasers were used - 405 nm and 510 nm. A difference for time of flight in normal skin and in nevus was observed as well as a difference for different wavelength laser irradiation was observed. For 405 nm laser irradiation the difference was 41 ps while comparison of time of flights skin and nevi using 510 nm irradiation showed a result of 32 ps. Results allow to conclude that the time photon travels in skin might depend on the characteristics of the medium and wavelength of the irradiation. This can be related to known data for light penetration depth in human skin for different w…

lcsh:Applied optics. PhotonicsMaterials sciencelcsh:Medical technologyAcoustics and UltrasonicsBiomedical EngineeringHuman skinmedical physicslaw.inventionBiomaterialsOpticslawIrradiationAbsorption (electromagnetic radiation)integumentary systembusiness.industrybiophotonicslcsh:TA1501-1820absorbtionLaserAtomic and Molecular Physics and OpticsBiophotonicsTime of flightWavelengthlight impulselcsh:R855-855.5PicosecondOptoelectronicsbusinessJournal of Biomedical Photonics & Engineering
researchProduct

Detection of liver metastases in cancer patients with geographic fatty infiltration of the liver: the added value of contrast-enhanced sonography

2017

Purpose The aim of this study is to assess the role of contrast-enhanced ultrasonography (CEUS) in the detection of liver metastases in cancer patients with geographic liver fatty deposition on greyscale ultrasonography (US). Methods Thirty-seven consecutive cancer patients (24 women and 13 men; age, 33 to 80 years; mean, 58.1 years) with geographic liver fatty deposition, but without any detectable focal liver lesion on greyscale US, underwent sulphur hexafluoride-enhanced US. Two readers reported by consensus the presence, size, and location of any detected lesion. All patients underwent magnetic resonance imaging (MRI) as a confirmatory study. Sensitivity, specificity, positive and negat…

medicine.medical_specialtylcsh:Medical technologyNeoplasm metastasisContrast media; Fatty liver; Liver diseases; Liver neoplasms; Neoplasm metastasis; UltrasonographyLiver neoplasm030218 nuclear medicine & medical imagingLesionHemangioma03 medical and health sciences0302 clinical medicineText miningLiver neoplasmsPositive predicative valueFatty livermedicineRadiology Nuclear Medicine and imagingNeoplasm metastasiLiver diseasesUltrasonographymedicine.diagnostic_testbusiness.industryContrast mediaFatty liverCancerMagnetic resonance imagingmedicine.diseaseConfidence intervallcsh:R855-855.5030220 oncology & carcinogenesisOriginal ArticleRadiologymedicine.symptomSettore MED/36 - Diagnostica Per Immagini E RadioterapiabusinessLiver diseaseUltrasonography
researchProduct

Herpes Simplex Esophagitis in Immunocompetent Host: A Case Report

2009

Introduction. Herpes simplex esophagitis is well recognized in immunosuppressed subjects, but it is infrequent in immunocompetent patients. We present a case of HSE in a 53-year-old healthy man. Materials and Methods. The patient was admitted with dysphagia, odynophagia, and retrosternal chest pain. An esophagogastroduodenoscopy revealed minute erosive area in distal esophagus and biopsies confirmed esophagitis and findings characteristic of Herpes Simplex Virus infection. Results. The patients was treated with high dose of protonpump inhibitor, sucralfate, and acyclovir, orally, with rapid resolution of symptoms. Discussion. HSV type I is the second most common cause of infectious esophagi…

medicine.medical_specialtyPathologylcsh:Medical technologymedicine.diagnostic_testbusiness.industryViral cultureEsophagogastroduodenoscopyCase Reportmedicine.diseaseDysphagiaDermatologyHerpes Simplex esophagitiSucralfatelcsh:R855-855.5immunocompetent hostmedicineRadiology Nuclear Medicine and imagingHistopathologyImmune disordermedicine.symptombusinessOdynophagiaEsophagitismedicine.drugDiagnostic and Therapeutic Endoscopy
researchProduct

Trans-Abdominal Ultrasound Guided ERC in a Pregnant Woman With Bile Duct Stones

2014

Background: The change in lithogenicity of bile, increased stasis of bile and decreased gall bladder emptying are the possible reasons for an increased risk of gall stones during pregnancy. However, biliary interventions during pregnancy are associated with risks to both the pregnancy and developing fetus. ERC under fluoroscopic control as gold standard is associated with higher risk of premature labor and teratogenity. Methods and patient: We performed transabdominal ultra-sound guided ERC in one patient in the second trimenon with gall stones. While the hilus area is observed by ultrasound, the papilla is carefully cannulated with a guidewire. A contrast agent is applied in the common bil…

Ultrasound guided ERCPmedicine.medical_specialtylcsh:Medical technologydigestive systemPregnancymedicineFluoroscopyRadiology Nuclear Medicine and imagingFetusPregnancyCommon bile ductmedicine.diagnostic_testBile ductbusiness.industryUltrasoundGastroenterologyVideomedicine.diseaseSurgeryMajor duodenal papillamedicine.anatomical_structurelcsh:R855-855.5ComplicationbusinessBile duct stonesComplicationVideo Journal and Encyclopedia of GI Endoscopy
researchProduct

Liver stiffness quantification in biopsy-proven nonalcoholic fatty liver disease patients using shear wave elastography in comparison with transient …

2021

Purpose: This study prospectively assessed the performance of liver stiffness measurements using point shear-wave elastography (p-SWE) in comparison with transient elastography (TE) in patients with biopsy-proven nonalcoholic fatty liver disease (NAFLD). Methods: Fifty-six consecutive adult patients with a histological diagnosis of NAFLD prospectively underwent TE and p-SWE on the same day. The median of 10 measurements (SWE-10), the first five (SWE-5), and the first three (SWE-3) measurements were analyzed for p-SWE. Liver biopsy was considered as the reference standard for liver fibrosis grade. Receiver operating characteristic (ROC) curves and areas under the ROC curves (AUROCs) were cal…

nonalcoholic fatty liver diseasemedicine.medical_specialtyGastroenterologySettore MED/01 - Statistica Medica030218 nuclear medicine & medical imaging03 medical and health sciences0302 clinical medicineLiver stiffnessInternal medicineStatistical significanceBiopsyNonalcoholic fatty liver diseaseMedical technologymedicineRadiology Nuclear Medicine and imagingnonalcoholic steatohepatitisR855-855.5shear wave elastographymedicine.diagnostic_testReceiver operating characteristicbusiness.industryNonalcoholic fatty liver disease Nonalcoholic steatohepatitis Shear wave elastography Transient elastography Liver stiffnessmedicine.diseasetransient elastographyliver stiffnessLiver biopsyOriginal Article030211 gastroenterology & hepatologyElastographySettore MED/36 - Diagnostica Per Immagini E RadioterapiabusinessTransient elastographyUltrasonography
researchProduct

Mean platelet volume in arterial and venous thrombotic disorders

2020

Abstract The mean platelet volume (MPV) is an easy, rapid and inexpensive laboratory parameter which basically mirrors platelet size. Due to the essential role of platelets in hemostasis, many studies have assessed the MPV value in patients with arterial and venous thrombotic disorders. These have then been summarized in some interesting meta-analyses and recent studies that will be discussed in this narrative review. Taken together, the currently available evidence suggests that the MPV may be substantially increased in concomitance with acute episodes of coronary artery disease, venous thromboembolism, portal vein thrombosis, stroke, erectile dysfunction and preeclampsia. In many of these…

medicine.medical_specialtyClinical Biochemistryvenous thromboembolism030204 cardiovascular system & hematologyCoronary artery disease03 medical and health sciences0302 clinical medicineInternal medicineMedical technologymedicineDiscrete Mathematics and CombinatoricsPlateletR855-855.5Mean platelet volumethrombosismean platelet volumebusiness.industryBiochemistry (medical)medicine.diseaseThrombosis030220 oncology & carcinogenesisplateletsCardiologycoronary artery disease; mean platelet volume; platelets; thrombosis; venous thromboembolismbusinessVenous thromboembolismcoronary artery disease
researchProduct

High Performance 3D PET Reconstruction Using Spherical Basis Functions on a Polar Grid

2011

Statistical iterative methods are a widely used method of image reconstruction in emission tomography. Traditionally, the image space is modelled as a combination of cubic voxels as a matter of simplicity. After reconstruction, images are routinely filtered to reduce statistical noise at the cost of spatial resolution degradation. An alternative to produce lower noise during reconstruction is to model the image space with spherical basis functions. These basis functions overlap in space producing a significantly large number of non-zero elements in the system response matrix (SRM) to store, which additionally leads to long reconstruction times. These two problems are partly overcome by expl…

lcsh:Medical physics. Medical radiology. Nuclear medicinelcsh:Medical technologyArticle SubjectComputer scienceStatistical noiseIterative methodImage qualitylcsh:R895-920ComputingMethodologies_IMAGEPROCESSINGANDCOMPUTERVISIONBasis functionReconstruction algorithmSpherical basisIterative reconstructioncomputer.software_genrelcsh:R855-855.5Radiology Nuclear Medicine and imagingData miningcomputerAlgorithmImage resolutionResearch ArticleComputingMethodologies_COMPUTERGRAPHICSInternational Journal of Biomedical Imaging
researchProduct

The factorization method for electrical impedance tomography data from a new planar device.

2006

We present numerical results for two reconstruction methods for a new planar electrical impedance tomography device. This prototype allows noninvasive medical imaging techniques if only one side of a patient is accessible for electric measurements. The two reconstruction methods have different properties: one is a linearization-type method that allows quantitative reconstructions; the other one, that is, the factorization method, is a qualitative one, and is designed to detect anomalies within the body.

lcsh:Medical physics. Medical radiology. Nuclear medicinelcsh:Medical technologyArticle SubjectComputer sciencebusiness.industrylcsh:R895-920Physics::Medical Physicscomputer.software_genreReconstruction methodPlanarlcsh:R855-855.5Medical imagingRadiology Nuclear Medicine and imagingComputer visionFactorization methodArtificial intelligenceData miningbusinessElectrical impedance tomographycomputerResearch ArticleInternational journal of biomedical imaging
researchProduct