Search results for "RADIATION"

showing 10 items of 5298 documents

A sun-induced vegetation fluorescence retrieval method from top of atmosphere radiance for the FLEX/Sentinel-3 TanDEM mission

2015

A new fluorescence retrieval method is proposed to support ESA's 8th Earth Explorer FLuorescence EXplorer/Sentinel-3 (FLEX-S3) candidate tandem mission. FLEX is the first mission specially dedicated to measure the Sun-Induced vegetation chlorophyll fluorescence (SIF) strongly related with the vegetation photosynthetic activity. Most hyperspectral fluorescence retrieval algorithms available in the literature are very sensitive to true reflectance modelization and/or they assume the atmospheric status as known. The proposed algorithm delivers the retrieval of full fluorescence spectrum at canopy level by using only Top Of Atmosphere (TOA) radiances from S3 and FLEX as input. Once the spatial …

business.industryAtmospheric correctionHyperspectral imagingAtmospheric modelAtmospheric correction FLEX Fluorescence retrieval Sentinel-3 Synergy productsAtmosphereGEO/10 - GEOFISICA DELLA TERRA SOLIDAOpticsRadianceEnvironmental scienceFLEXAbsorption (electromagnetic radiation)businessChlorophyll fluorescenceRemote sensing2015 IEEE International Geoscience and Remote Sensing Symposium (IGARSS)
researchProduct

Microspectroscopy and spectromicroscopy with photoemission electron microscopy using a new kind of imaging energy filter

2001

The use of an imaging retarding field analyser attached to the FOCUS IS-PEEM is described. This kind of energy filter is a simple, powerful tool to obtain microspectra from areas of down to about 1 μm using (V)UV and X-ray excitation sources. First results of microspectroscopy measured by excitation with a laboratory as well as a synchrotron X-ray source are presented.

business.industryChemistryAnalyserSynchrotron radiationSurfaces and InterfacesCondensed Matter PhysicsSynchrotronSurfaces Coatings and Filmslaw.inventionPhotoemission electron microscopyOpticsX-ray photoelectron spectroscopyFilter (video)lawMaterials ChemistryElectron microscopebusinessExcitationSurface Science
researchProduct

Photokinetic examination of (Z,E,E)-4,4′-distyrylazobenzene

1995

Abstract 4,4′-Distyrylazobenzenes demonstrate a photokinetic equilibrium and a superimposed thermal backward reaction in which the absorption coefficient of one of the partners in the equilibrium is principally unknown. Using the dependence of the photostationary state on the irradiation intensity, the photochemical quantum yields ϕ 1 A and ϕ 2 B were determined, as well as the thermal rate constant k , as a function of the irradiation and observation wavelengths. Experimental difficulties and the wavelength dependence of ϕ 1 A and ϕ 2 B are discussed.

business.industryChemistryGeneral Chemical EngineeringGeneral Physics and AstronomyQuantum yieldGeneral ChemistryMolecular electronic transitionWavelengthOpticsReaction rate constantPhotostationary stateAttenuation coefficientAbsorptanceIrradiationAtomic physicsbusinessJournal of Photochemistry and Photobiology A: Chemistry
researchProduct

Thioxanthone: on the shape of the first absorption band

2010

The equilibrium ground state geometry of thioxanthone (TX) has been investigated and its effect on the vertical excitation energies and photophysical behaviour has been explained. In line with this purpose, the first absorption band of TX has been simulated and analysed in detail. The calculations show that TX is planar, C(2v) symmetric in its ground state. The energy of the low-lying excited states seems to be rather insensitive along the butterfly motion coordinate. The shoulder in the first absorption band (at around 3.43 eV) is shown to be caused by vibrational progression of various in-plane modes and does not justify the hypothesis that two photophysically distinct conformers of TX ex…

business.industryChemistryGeneral Physics and AstronomyThioxanthoneMolecular physicsOpticsAbsorption bandExcited statePhysical and Theoretical ChemistrybusinessGround stateAbsorption (electromagnetic radiation)Conformational isomerismExcitationLine (formation)Physical Chemistry Chemical Physics
researchProduct

Material quality characterization of CdZnTe substrates for HgCdTe epitaxy

2006

Cd1−xZnxTe (CZT) substrates were studied to investigate their bulk and surface properties. Imperfections in CZT substrates affect the quality of Hg1−xCdxTe (MCT) epilayers deposited on them and play a role in limiting the performance of infrared (IR) focal plane arrays. CZT wafers were studied to investigate their bulk and surface properties. Transmission and surface x-ray diffraction techniques, utilizing both a conventional closed-tube x-ray source as well as a synchrotron radiation source, and IR transmission micro-spectroscopy, were used for bulk and surface investigation. Synchrotron radiation offers the capability to combine good spatial resolution and shorter exposure times than conv…

business.industryChemistryNeutron diffractionSynchrotron Radiation SourceSynchrotron radiationCondensed Matter PhysicsEpitaxySettore ING-INF/01 - ElettronicaCadmium telluride photovoltaicsElectronic Optical and Magnetic MaterialsOpticsMaterials ChemistryCadmium alloysCadmium tellurideGrain boundaryWaferElectrical and Electronic EngineeringbusinessMolecular beam epitaxyMolecular beam epitaxy
researchProduct

Synchrotron radiation multiple diffraction study of Al0.304Ga0.172In0.524As MOVPE grown onto InP(001)

1997

Synchrotron radiation multiple diffraction in Renninger scanning (RS) geometry is used to characterise an Al0.304Ga0.172In0.524 As hetero-epitaxial layer MOVPE grown onto InP(001). (006) RS data for bulk, InP substrate and the quaternary layer were obtained using a new experimental set-up on station 7.6 at the Daresbury synchrotron radiation source. Examination of the multiple diffraction peak profiles reveal the epitaxial layers to have a higher mosaic spread than the underlying substrate materials. Measurements of the layer parallel lattice parameter a∥ = 5.8755 ± 0.003 A, as deduced from the tetragonal distortion measured at the 6-beam case in the layer RS, agrees very well with that obt…

business.industryChemistrySynchrotron Radiation SourceAnalytical chemistrySynchrotron radiationSubstrate (electronics)Condensed Matter PhysicsEpitaxyInorganic ChemistryTetragonal crystal systemLattice constantOpticsMaterials ChemistryMetalorganic vapour phase epitaxybusinessLayer (electronics)Journal of Crystal Growth
researchProduct

Analysis of the Effect of Human Presence on a Wireless Sensor Network

2011

Wireless Sensor Networks (WSNs) are gaining an increasing industry wide adoption. However, there remain major challenges such as network dimensioning and node placement especially in Built Environment Networks (BENs). Decisions on the node placement, orientation, and the number of nodes to cover the area of interest are usually ad-hoc. Ray tracing tools are traditionally employed to predict RF signal propagation; however, such tools are primarily intended for outdoor environments. RF signal propagation varies greatly indoors due to building materials and infrastructure, obstacles, node placement, antenna orientation and human presence. Because of the complexity of signal prediction, these f…

business.industryComputer scienceSettore ING-INF/03 - TelecomunicazioniRSSReal-time computingcomputer.file_formatRadio propagationKey distribution in wireless sensor networksBuilt Environment Networks (BENs) Human Presence Node Placement Radiation Patterns Wireless Sensor Networks (WSNs)Ray tracing (graphics)Radio frequencyTransceiverbusinessWireless sensor networkcomputerDimensioningSoftwareComputer network
researchProduct

Hybrid 3D-ResNet Deep Learning Model for Automatic Segmentation of Thoracic Organs at Risk in CT Images

2020

In image radiation therapy, accurate segmentation of organs at risk (OARs) is a very essential task and has clinical applications in cancer treatment. The segmentation of organs close to lung, breast, or esophageal cancer is a routine and time-consuming process. The automatic segmentation of organs at risk would be an essential part of treatment planning for patients suffering radiotherapy. The position and shape variation, morphology inherent and low soft tissue contrast between neighboring organs across each patient’s scans is the challenging task for automatic segmentation of OARs in Computed Tomography (CT) images. The objective of this paper is to use automatic segmentation of the orga…

business.industryComputer sciencemedicine.medical_treatmentDeep learningVolumetric segmentationPattern recognition02 engineering and technologyResidual neural network030218 nuclear medicine & medical imagingRadiation therapy03 medical and health sciences0302 clinical medicine0202 electrical engineering electronic engineering information engineeringmedicineAutomatic segmentation020201 artificial intelligence & image processingSegmentationPyramid (image processing)Artificial intelligencebusinessRadiation treatment planning2020 International Conference on Industrial Engineering, Applications and Manufacturing (ICIEAM)
researchProduct

Calculated organ doses using Monte Carlo simulations in a reference male phantom undergoing HDR brachytherapy applied to localized prostate carcinoma

2013

Purpose : The aim of this study was to obtain equivalent doses in radiosensitive organs (aside from the bladder and rectum) when applying high-dose-rate (HDR) brachytherapy to a localized prostate carcinoma using60Co or 192 Ir sources. These data are compared with results in a water phantom and with expected values in an infinite water medium. A comparison with reported values from proton therapy and intensity-modulated radiation therapy (IMRT) is also provided. Methods : Monte Carlo simulations in Geant4 were performed using a voxelized phantom described in International Commission on Radiological Protection (ICRP) Publication 110, which reproduces masses and shapes from an adult reference…

business.industryEquivalent dosemedicine.medical_treatmentBrachytherapyGeneral MedicineEffective dose (radiation)Imaging phantomRadiation therapyAbsorbed doseMedicineDosimetrybusinessNuclear medicineProton therapyMedical Physics
researchProduct

Monte Carlo dosimetric study of the Flexisource Co-60 high dose rate source.

2011

Purpose: Recently, a new HDR 60 Co brachytherapy source, Flexisource Co-60, has been developed (Nucletron B.V. Veenendaal, The Netherlands). This study aims to obtain dosimetric data for this source for its use in clinical practice as required by AAPM and ESTRO. Material and methods: Two Monte Carlo radiation transport codes were used: Penelope2008 and GEANT4. The source was centrally-positioned in a 100 cm radius water phantom. Absorbed dose and collisional kerma were obtained using 0.01 cm (close) and 0.1 cm (far) sized voxels to provide high-resolution dosimetry near (far from) the source. Dose rate distributions obtained with the two Monte Carlo codes were compared. Results and Discussi…

business.industryFlexisource Co-60Penelope2008medicine.medical_treatmentBrachytherapyMonte Carlo methodbrachytherapyImaging phantomComputational physicsKermaOncologyAbsorbed doseMedicineDosimetryRadiology Nuclear Medicine and imagingOriginal ArticlebusinessDose rateRadiation treatment planningNuclear medicineTG-43GEANT4Journal of contemporary brachytherapy
researchProduct