Search results for "RADIATION"

showing 10 items of 5298 documents

Radiation exposure to the hands and the thyroid of the surgeon during intramedullary nailing.

1998

Abstract During 41 procedures of intramedullary nailing of femoral and tibial fractures, the primary surgeon and the first assistant wore ring dosimeters on their dominant index fingers. While the average fluoroscopy time per procedure was 4.6 min, the average dose of radiation to the dominant hand of the primary surgeon was 1.27 mSv and 1.19 mSv to the first assistant. The dose limit for the extremities is 500 mSv per year, as recommended by the International Commission on Radiological Protection. Extrapolation of the mean dose of the primary surgeon and first assistent per procedure of 1.23 mSv leads to the result that the recommended dose limit of 500 mSv would only be exceeded if more t…

medicine.medical_specialtyFilm DosimetryThyroid GlandWorkloadIonizing radiationlaw.inventionIntramedullary rodIntraoperative PeriodRadiation ProtectionlawOccupational ExposuremedicineFluoroscopyHumansFemurTibiaFemurRadiation InjuriesOccupational HealthGeneral Environmental ScienceDosimetermedicine.diagnostic_testTibiabusiness.industryPhantoms ImagingHandFracture Fixation IntramedullaryTibial FracturesOrthopedicsRadiological weaponFluoroscopyOrthopedic surgeryGeneral Earth and Planetary SciencesbusinessNuclear medicineFemoral FracturesInjury
researchProduct

Stereotactic Radiotherapy plus Radiosurgical Boost in the Treatment of Large Cerebral Arteriovenous Malformations

1993

Small sized AVMs respond well to stereotactic radiosurgery, while larger AVMs do poorly with stereotactic radiosurgery or stereotactic fractionated radiotherapy. A combination of both methods is proposed for the treatment of these larger lesions.

medicine.medical_specialtyFractionated radiotherapymedicine.diagnostic_testbusiness.industrymedicine.medical_treatmentRadiosurgeryCerebral arteriovenous malformationsRadiation therapyStereotactic radiotherapyStereotaxic techniquemedicineIntracranial Arteriovenous MalformationsRadiologybusinessCerebral angiography
researchProduct

Exclusive MRI-based tandem and colpostats reconstruction in gynaecological brachytherapy treatment planning

2008

Purpose: According to the GYN GEC-ESTRO Recommendations, MRI is needed with the modality of T2 weighted. CT-MR compatible tandem Plus colpostats (T/C) (Nucletron) is widely used in cervical brachytherapy. The major challenge of MRI is the lack of dummy catheters. Therefore, an additional imaging modality is usually required. One disadvantage of sliced-based reconstruction is that resolution in longitudinal directions can be affected by the slice thickness. The aim of this study is to present a modified T/C applicator in which the catheter visibility is significantly improved. Methods and materials: A modification to the existing T/C applicator has been made available, increasing the cathete…

medicine.medical_specialtyGenital Neoplasms Femalebusiness.industryRadiotherapy Planning Computer-AssistedSlice thicknessmedicine.medical_treatmentBrachytherapyBrachytherapyRadiotherapy DosageHematologyMagnetic Resonance ImagingCatheterizationCatheterOncologymedicineHumansDosimetryFemaleRadiology Nuclear Medicine and imagingRadiologyNuclear medicinebusinessRadiation treatment planningT2 weighted
researchProduct

Is intraoperative neuromonitoring associated with better functional outcome in patients undergoing open TME?

2013

Aims: Intraoperative neuromonitoring (IONM) aims to control nerve-sparing total mesorectal excision (TME) for rectal cancer in order to improve patients’ functional outcome. This study was designed to compare the urogenital and anorectal functional outcome of TME with and without IONM of innervation to the bladder and the internal anal sphincter. Methods: A consecutive series of 150 patients with primary rectal cancer were analysed. Fifteen match pairs with open TME and combined urogenital and anorectal functional assessment at follow up were established identical regarding gender, tumour site, tumour stage, neoadjuvant radiotherapy and type of surgery. Urogenital and anorectal function was…

medicine.medical_specialtyGenitourinary systemColorectal cancerbusiness.industryUrinary systemmedicine.medical_treatmentGeneral Medicinemedicine.diseaseTotal mesorectal excisionInternal anal sphincterlaw.inventionSurgeryRadiation therapySexual dysfunctionOncologyRandomized controlled triallawmedicineSurgerymedicine.symptombusiness
researchProduct

Quantification of fibrosis in chronic hepatitis C: Performance of Transient Elastography and Acoustic Radiation Force Impulse using Collagen Proporti…

2014

medicine.medical_specialtyHepatologyChronic hepatitisbusiness.industryFibrosisGastroenterologyMedicineRadiologyImpulse (physics)businessTransient elastographymedicine.diseaseAcoustic radiation forceDigestive and Liver Disease
researchProduct

The value of high resolution CT in the diagnosis of meniscal lesions of the knee

1991

We report on 50 patients who had meniscal pathology and were given computed tomographic (CT) scans. Our diagnostic accuracy was approximately 92%. We believe that CT is a good method of screening these patients prior to using a much more expensive method, such as magnetic resonance imaging or diagnostic arthroscopy.

medicine.medical_specialtyHigh resolutionDiagnostic accuracyMeniscus (anatomy)Radiation DosageMenisci TibialSensitivity and SpecificityArthroscopyPredictive Value of TestsmedicineHumansOrthopedics and Sports MedicineProspective StudiesDiagnostic arthroscopymedicine.diagnostic_testbusiness.industryArthroscopyMagnetic resonance imagingMagnetic Resonance ImagingTibial Meniscus Injuriesmedicine.anatomical_structurePredictive value of testsCosts and Cost AnalysisRadiologyTomography X-Ray ComputedbusinessMeniscal lesionsArthroscopy: The Journal of Arthroscopic & Related Surgery
researchProduct

Determination of Minimal Erythema Dose and Anomalous Reactions to UVA Radiation by Skin Phototype

2014

Background: Phototesting is a technique that assesses the skin’s sensitivity to UV radiation by determining the smallest dose of radiation capable of inducing erythema (minimal erythema dose [MED]) and anomalous responses to UV-A radiation. No phototesting protocol guidelines have been published to date. Methodology: This was a multicenter prospective cohort study in which 232 healthy volunteers were recruited at 9 hospitals. Phototests were carried out with solar simulators or fluorescent broadband UV-B lamps. Each individual received a total of 5 or 6 incremental doses of erythemal radiation and 4 doses of UV-A radiation. The results were read at 24 hours. Results: At hospitals where sola…

medicine.medical_specialtyHistologyintegumentary systemErythemaUVA Radiationbusiness.industryDermatologyPhototypeDermatologyPathology and Forensic MedicineSurgeryMinimal erythema doseHealthy volunteersmedicinePhototestingmedicine.symptombusinessProspective cohort studyActas Dermo-Sifiliográficas (English Edition)
researchProduct

A new treatment for severe malabsorption due to radiation enteritis.

1996

medicine.medical_specialtyHyperbaric OxygenationMalabsorptionRadiotherapybusiness.industrymedicine.medical_treatmentGeneral MedicineMiddle Agedmedicine.diseaseGastroenterologyEnteritisEnteritisRadiation therapyIntestinal malabsorptionInternal medicinemedicineRadiation EnteritisHumansFemaleComplicationbusinessRadiation InjuriesRadiation injuryLancet (London, England)
researchProduct

Implementation of dosimetry equipment and phantoms at the MedAustron light ion beam therapy facility

2017

Purpose: To describe the implementation of dosimetry equipment and phantoms into clinical practice of light ion beam therapy facilities. This work covers standard dosimetry equipment such as computerized water scanners, films, 2D-array, thimble and plane parallel ionization chambers, but also dosimetry equipment specifically devoted to the pencil beam scanning delivery technique such as water columns, scintillating screens or multi-layer ionization chambers. Method: Advanced acceptance testing procedures developed at MedAustron and complementary to the standard acceptance procedures proposed by the manufacturer are presented. Detailed commissioning plans have been implemented for each piece…

medicine.medical_specialtyIon beamComputer scienceNuclear engineeringmedicine.medical_treatmentImaging phantomPelvis030218 nuclear medicine & medical imagingMedical physicist03 medical and health sciences0302 clinical medicinemedicineHumansDosimetryMedical physicsRadiometryPencil-beam scanningIonsPhantoms ImagingRadiation DosimetersUncertaintyGeneral MedicinePencil (optics)Radiation therapy030220 oncology & carcinogenesisSoftwareMedical Physics
researchProduct

A CAD system for nodule detection in low-dose lung CTs based on region growing and a new active contour model

2007

A computer-aided detection (CAD) system for the selection of lung nodules in computer tomography (CT) images is presented. The system is based on region growing (RG) algorithms and a new active contour model (ACM), implementing a local convex hull, able to draw the correct contour of the lung parenchyma and to include the pleural nodules. The CAD consists of three steps: (1) the lung parenchymal volume is segmented by means of a RG algorithm; the pleural nodules are included through the new ACM technique; (2) a RG algorithm is iteratively applied to the previously segmented volume in order to detect the candidate nodules; (3) a double-threshold cut and a neural network are applied to reduce…

medicine.medical_specialtyLung NeoplasmsRadiation DosageModels BiologicalEdge detectionImage processingMedical imagingmedicineHumansDiagnosis Computer-AssistedComputed radiographycomputer-aided diagnosis (CAD)Lungimage segmentationComputed tomographyActive contour modelImage segmentationbusiness.industrycomputed tomographyGeneral MedicineImage segmentationComputer-aided diagnosis (CAD)image processingROC CurveRegion growingComputer-aided diagnosisRadiologyTomographyNeural Networks Computercomputer-aided diagnosis (CAD)image processingcomputed tomographyimage segmentationNuclear medicinebusinessTomography X-Ray ComputedAlgorithms
researchProduct