Search results for "RADIOTHERAPY"

showing 10 items of 473 documents

Quantification of Radiation Biomarkers in Leukocytes of Breast Cancer Patients Treated with Different Modalities of 3D-CRT or IMRT

2016

The goal of this study was to determine whether the quantification of radiation biomarkers in peripheral leukocytes of 111 breast cancer patients after adjuvant treatment with different modalities of three-dimensional conformal radiation therapy (3D-CRT) or intensity-modulated radiation therapy (IMRT) revealed any difference in the patients' radiation burden by out-of-field doses and an associated risk of second malignancies. Whole-breast radiation therapy was performed by 3D-CRT using either a hard wedge (n = 32) or a virtual wedge (n = 49) at dose rates of 3 and 6 Gy per min each. Patients receiving additional radiotherapy to lymph nodes were treated by 3D-CRT (n = 21) or IMRT (n = 9). DN…

Riskmedicine.medical_treatmentBiophysicsBreast Neoplasms030218 nuclear medicine & medical imagingHistones03 medical and health sciencesBasal (phylogenetics)0302 clinical medicineRadiation sensitivityBreast cancerLeukocytesmedicineHumansRadiology Nuclear Medicine and imagingChromosome AberrationsRadiationbusiness.industryDose-Response Relationship Radiationmedicine.diseasePeripheralRadiation therapy030220 oncology & carcinogenesisFemaleRadiotherapy Intensity-ModulatedLymphbusinessNuclear medicineAdjuvantBiomarkersEx vivoRadiation Research
researchProduct

Sviluppo e Applicazioni di nuovi materiali per la dosimetria delle radiazioni ionizzanti

The Research Activities carried out during the Three-year International PhD Course in Applied Physics of the candidate Salvatore Gallo had two main topics related to dosimetry of ionizing radiations (IR): the analysis of 3D gel dosimeters and the analysis of solid state dosimeters through electron spin resonance. Both these activities are focused on a careful study of new materials for the IR Dosimetry, both in terms of physical characterization of these new materials and of the optimization of readout methods for dosimetric measurements. The study performed through various techniques such as UV-Vis absorption spectroscopy, NMR Relaxometry, Magnetic Resonance Imaging (MRI) and Electron Spin…

Settore FIS/01 - Fisica SperimentaleDosimetry ESR Spectroscopy NMR Relaxometry MRI Fricke gel dosimetry Xylenol Orange Irganox 1076 RadiotherapySettore FIS/07 - Fisica Applicata(Beni Culturali Ambientali Biol.e Medicin)
researchProduct

A Graph-Based Method for PET Image Segmentation in Radiotherapy Planning: A Pilot Study

2013

Target volume delineation of Positron Emission Tomography (PET) images in radiation treatment planning is challenging because of the low spatial resolution and high noise level in PET data. The aim of this work is the devel- opment of an accurate and fast method for semi-automatic segmentation of me- tabolic regions on PET images. For this purpose, an algorithm for the biological tumor volume delineation based on random walks on graphs has been used. Va- lidation was first performed on phantoms containing spheres and irregular in- serts of different and known volumes, then tumors from a patient with head and neck cancer were segmented to discuss the clinical applicability of this algo- rith…

Settore ING-INF/05 - Sistemi Di Elaborazione Delle Informazionimedicine.diagnostic_testRadiotherapybusiness.industryComputer sciencemedicine.medical_treatmentGraph basedHead and Neck cancerImage segmentationGraphGraphRadiation therapySegmentationPETPositron emission tomographymedicineSegmentationComputer visionSegmentation Graph PET Head and Neck cancer RadiotherapyArtificial intelligenceRadiation treatment planningbusinessImage resolution
researchProduct

ORAL MUCOSITIS

2010

The standard treatment for malignant neoplasia of the cervicofacial area is surgery in association with radio- and/or chemotherapy. These therapies can cause local and systemic complications. Mucositis is the most common dosecorrelated complication to the oral cavity. It is particularly difficult to treat in patients who are already physically and psychologically exhausted by the tumoral pathology. This study illustrates, through a review of the literature, the attack rate, the pathogenesis and the clinical course of the mucositis, as well as the correct dental approach and clinical- therapeutic management of these patients, with the aim of improving the quality of their lives.

Settore MED/28 - Malattie OdontostomatologicheORAL MUCOSITIS RADIOTHERAPY CHEMIOTERAPY
researchProduct

Adjuvant volumetric-modulated arc therapy with simultaneous integrated boost in endometrial cancer. Planning and toxicity comparison

2014

Objective. To report dosimetric and acute toxicity data in prospectively enrolled high-intermediate risk endometrial cancer (HIR-EC) patients postoperatively irradiated by simultaneous integrated boost volumetric modulated arc therapy (SIB-VMAT). Methods. Thirty prospectively enrolled HIR-EC patients were postoperatively treated by SIB-VMAT. Target coverage, dose homogeneity, and sparing of organs at risk (OARs) were compared with corresponding data retrieved from an historical control (30 consecutive selected matched patients) treated by concomitant boost three-dimensional conformal radiotherapy (3D CRT CB) from a previously published study (ADA-I trial). All patients received 45 Gy on pel…

Simultaneous integrated boostAdultOrgans at RiskRadiology Nuclear Medicine and Imagingmedicine.medical_treatmentRectumvolumetric-modulated arc therapyMedicineHumansAgedAged 80 and overbusiness.industryEndometrial cancerRadiotherapy Planning Computer-AssistedtoxicityRadiotherapy DosageGeneral MedicineHematologyMiddle Agedmedicine.diseaseVolumetric modulated arc therapyAcute toxicityEndometrial Neoplasmsmedicine.anatomical_structureOncologysimultaneous integrated boostToxicityendometrial cancerVaginal vaultFemaleRadiotherapy Intensity-ModulatedbusinessNuclear medicineAdjuvant
researchProduct

Weekly Cisplatin and Volumetric-Modulated Arc Therapy With Simultaneous Integrated Boost for Radical Treatment of Advanced Cervical Cancer in Elderly…

2016

Background: To evaluate the feasibility and clinical preliminary results of weekly cisplatin and volumetric-modulated arc therapy to the pelvis with simultaneous integrated boost to macroscopic disease in a cohort of elderly patients. Materials and Methods: Inclusion criteria of this prospective study were age ≥70 years, Karnofsky performance status 70 to 100, locally advanced histologically proven squamous cervical carcinoma, and patients unable to undergo brachytherapy. Radiation doses prescribed were 66 Gy to the macroscopic disease and 54 Gy to the pelvic nodes in 30 fractions. Weekly cisplatin dose was 40 mg/mq. Results: A total of 30 patients were recruited. Median follow-up was 32 mo…

Simultaneous integrated boostMalemedicine.medical_specialtyCancer ResearchBrachytherapyUterine Cervical NeoplasmsVMATelderly patients030218 nuclear medicine & medical imaging03 medical and health sciences0302 clinical medicineWeekly cisplatinmedicineArc therapyHumansAgedCervical cancerRadical treatmentAged 80 and overbusiness.industryRadiotherapy DosageArticlesmedicine.diseaseVolumetric modulated arc therapyCombined Modality TherapySurgeryOncology030220 oncology & carcinogenesisCarcinoma Squamous CellVMAT; advanced cervical cancer; elderly patients; gynecological malignanciesFemaleadvanced cervical cancer; elderly patients; gynecological malignancies; VMAT; Oncology; Cancer ResearchRadiologyDose Fractionation RadiationLymph NodesRadiotherapy Intensity-ModulatedCisplatinbusinessgynecological malignanciesadvanced cervical cancer
researchProduct

Dosimetry comparison between TG-43 and Monte Carlo calculations using the Freiburg flap for skin high-dose-rate brachytherapy

2012

Abstract Purpose The purpose of this work was to evaluate whether the delivered dose to the skin surface and at the prescription depth when using a Freiburg flap applicator is in agreement with the one predicted by the treatment planning system (TPS) using the TG-43 dose-calculation formalism. Methods and Materials Monte Carlo (MC) simulations and radiochromic film measurements have been performed to obtain dose distributions with the source located at the center of one of the spheres and between two spheres. Primary and scatter dose contributions were evaluated to understand the role played by the scatter component. A standard treatment plan was generated using MC- and TG-43-based TPS appl…

Skin Neoplasmsmedicine.medical_treatmentBrachytherapyBrachytherapyMonte Carlo methodSensitivity and SpecificitySkin surfacemedicineHumansDosimetryRadiology Nuclear Medicine and imagingRadiochromic filmRadiation treatment planningSkinbusiness.industryRadiotherapy Planning Computer-AssistedReproducibility of ResultsRadiotherapy DosageEquipment DesignHigh-Dose Rate BrachytherapyComputational physicsEquipment Failure AnalysisOncologySPHERESNuclear medicinebusinessMonte Carlo MethodSoftwareBrachytherapy
researchProduct

Correction factors for ionization chamber measurements with the ‘Valencia’ and ‘large field Valencia’ brachytherapy applicators

2018

Treatment of small skin lesions using HDR brachytherapy applicators is a widely used technique. The shielded applicators currently available in clinical practice are based on a tungsten-alloy cup that collimates the source-emitted radiation into a small region, hence protecting nearby tissues. The goal of this manuscript is to evaluate the correction factors required for dose measurements with a plane-parallel ionization chamber typically used in clinical brachytherapy for the 'Valencia' and 'large field Valencia' shielded applicators. Monte Carlo simulations have been performed using the PENELOPE-2014 system to determine the absorbed dose deposited in a water phantom and in the chamber act…

Skin Neoplasmsmedicine.medical_treatmentBrachytherapyPhysics::Medical PhysicsMonte Carlo methodBrachytherapyDose profileRadiationImaging phantom030218 nuclear medicine & medical imaging03 medical and health sciences0302 clinical medicineOpticsmedicineRadiology Nuclear Medicine and imagingRadiometryValenciaPhysicsRadiological and Ultrasound TechnologybiologyPhantoms ImagingRadiation Dosimetersbusiness.industryRadiotherapy Dosagebiology.organism_classification030220 oncology & carcinogenesisAbsorbed doseIonization chamberbusinessMonte Carlo MethodPhysics in Medicine & Biology
researchProduct

Multimodal approaches to the treatment of hepatocellular carcinoma.

2008

The prevalence of hepatocellular carcinoma in Europe and the US is increasing and is currently the leading cause of death in patients with cirrhosis. Surveillance programs for patients with cirrhosis aim to detect tumors at an early stage, when the greatest therapeutic benefits can be achieved. Curative treatments for early-stage tumors include liver transplantation, resection and percutaneous ablation. Transarterial chemoembolization (TACE) and sorafenib can improve survival for patients with intermediate and advanced tumors, respectively. In clinical practice, combination therapies are often used, despite limited evidence to support this approach from randomized controlled trials. Combina…

SorafenibNiacinamidemedicine.medical_specialtyCarcinoma HepatocellularCombination therapyWaiting ListsRadiofrequency ablationPyridinesmedicine.medical_treatmentSalvage therapyAntineoplastic AgentsLiver transplantationlaw.inventionInjectionslawPreoperative CaremedicineCombined Modality TherapyHumansChemoembolization TherapeuticSalvage TherapyHepatologyEthanolbusiness.industryepatocarcinoma cirrosi HBV HCVPhenylurea CompoundsBenzenesulfonatesLiver NeoplasmsGastroenterologySorafenibmedicine.diseaseCombined Modality TherapyEmbolization TherapeuticSurgeryLiver TransplantationHepatocellular carcinomaCatheter AblationRadiotherapy AdjuvantRadiologyPercutaneous ethanol injectionbusinessmedicine.drugNature clinical practice. Gastroenterologyhepatology
researchProduct

Stereotactic Radiosurgery of Deeply Seated Low Grade Gliomas

1994

The authors report the results of a series of 16 cases of low-grade gliomas in whom radiosurgery was performed. This series started in 1977. All the tumours received a single radiosurgical session (with a mean dose of 21.7 Gy, 5–10mm. collimator; one patient received two sessions and in another patient two different targets were irradiated in the same session). Prior to radiosurgery, six patients received conventional external fractionated radiotherapy, with two lateral fields of up to 10 × 10 cm. and a mean dose of 55.1 Gy. and another six patients with tumours less than 5 cm. in diameter, received stereotactic radiotherapy using four fields of up to 5 × 5 cm. and a mean dose of 53.1 Gy. I…

Stereotactic radiotherapyConventional fractionationFractionated radiotherapybusiness.industrymedicine.medical_treatmentmedicineNuclear medicinebusinessRadiosurgery
researchProduct