Search results for "RAV"

showing 10 items of 5866 documents

Simple high-performance liquid chromatographic assay for polyamines and their monoacetyl derivatives.

1993

A rapid reversed-phase high-performance liquid chromatographic method, using pre-column derivatization with benzoyl chloride and ultraviolet detection at 254 nm, was developed for the simultaneous measurement of polyamines and their monoacetyl derivatives. Calibration curves were linear for concentrations from 1.25 to 25 nmol/ml. The method was employed to assay these compounds in chick embryo retina explants using organic solvent extraction and 1,7-diaminoheptane as an internal standard. This simple and sensitive method can be applied to routine determinations of these compounds in various biological samples.

ChromatographyCalibration curveOrganic solventExtraction (chemistry)Reproducibility of ResultsAcetylationGeneral ChemistryChick EmbryoDiaminesHigh-performance liquid chromatographyRetinachemistry.chemical_compoundBenzoyl chloridechemistryPolyaminesAnimalsSpectrophotometry UltravioletDerivatizationQuantitative analysis (chemistry)Chromatography High Pressure LiquidJournal of chromatography
researchProduct

Evaluation by HPLC-UV of Polar Pesticides in Rice Fields

1999

ChromatographyChemical PhenomenaChemistry PhysicalHealth Toxicology and MutagenesisPesticide ResiduesOryzaGeneral MedicineHydrogen-Ion ConcentrationPesticideToxicologyPollutionHigh-performance liquid chromatographySurface-Active AgentsSpainEnvironmental sciencePaddy fieldPolarSpectrophotometry UltravioletTrace analysisSample preparationSolid phase extractionPesticidesChromatography High Pressure LiquidHalf-LifeBulletin of Environmental Contamination and Toxicology
researchProduct

Extraction of clenbuterol from calf urine using a molecularly imprinted polymer followed by quantitation by high-performance liquid chromatography wi…

2002

A method for the extraction of clenbuterol from calf urine samples using a molecularly imprinted polymer (MIP) has been developed. The aim was that the final extracts from the MIP should allow quantitation of clenbuterol down to 0.5 ng/mL urine using HPLC with UV detection. The MIP was produced using brombuterol as a template and the selectivity of the MIP, for clenbuterol, was tested against a non-imprinted polymer (produced without template) and was found to be high. After loading of 5 mL diluted centrifuged urine, selective binding was established in acetonitrile-acetic acid (98:2). For further elution of interferences, 0.5 M ammonium acetate buffer pH 5 and 70% acetonitrile in water was…

ChromatographyChemistryElutionOrganic ChemistryExtraction (chemistry)Molecularly imprinted polymerReproducibility of ResultsGeneral MedicineReversed-phase chromatographyReference StandardsSensitivity and SpecificityBiochemistryHigh-performance liquid chromatographyAnalytical ChemistryClenbuterolmedicineAnimalsCattleClenbuterolSpectrophotometry UltravioletSample preparationSolid phase extractionAdrenergic alpha-AgonistsChromatography High Pressure Liquidmedicine.drugJournal of Chromatography A
researchProduct

A New Simple Static Method for the Determination of Solubilities of Condensed Compounds in Supercritical Fluids

2002

Abstract A simple static method based on gravimetric measurements has been adopted to measure the solubility of benzenecarboxylic acid, 2-hydroxy-benzenecarboxylic acid, 4-hydroxy-benzenecarboxylic acid and 1,8-dihydroxyanthraquinone along several isotherms in the temperature range 318–357 K and the pressure interval 7–23 MPa. Solubility data have been correlated with the Zieger–Eckert approach, using the Fedor atomic and group contribution method to estimate the solubility parameter and the molar volume of the solutes. A good agreement was obtained between data reported in the literature and those determined using the proposed method which allows one to measure solubility mole fraction as …

ChromatographyChemistryGeneral Chemical EngineeringAnalytical techniqueThermodynamicsSettore ING-IND/27 - Chimica Industriale E TecnologicaCondensed Matter PhysicsMole fractionGravimetric measurementsGroup contribution methodSupercritical fluidLow volatile compoundHildebrand solubility parameterMolar volumeSolubilityCarbon dioxideGravimetric analysisPhysical and Theoretical ChemistrySolubilityPhase equilibria
researchProduct

Determination of alinidine in human plasma by high-performance liquid chromatography.

1981

ChromatographyChemistryHydrophilic interaction chromatographyAdministration OralGeneral ChemistryHigh-performance liquid chromatographyClonidineColumn chromatographyHuman plasmaReference ValuesAlinidineInjections IntravenousSupercritical fluid chromatographyHumansChromatography columnChromatography High Pressure LiquidHalf-LifeJournal of chromatography
researchProduct

Improvement of peak shape and separation performance of beta-blockers in conventional reversed-phase columns using solvent modifiers.

2003

A comparative study of peak shape, elution behavior, and resolution of 16 beta-blockers (acebutolol, alprenolol, atenolol, bisoprolol, carteolol, celiprolol, esmolol, labetalol, metoprolol, nadolol, oxprenolol, pindolol, practolol, propranolol, sotalol, and timolol) chromatographed with hybrid mobile phases of triethylamine (TEA)-acetonitrile and sodium dodecyl sulfate (SDS)-propanol is performed using conventional reversed-phase columns and isocratic elution. Both solvent modifiers (TEA and SDS) prevent the interaction of the basic drugs with the alkyl-bonded phase. However, the protection mechanisms of silanols on the packing are different. Whereas TEA associates with the silanol sites (b…

ChromatographyElutionAdrenergic beta-AntagonistsAnalytical chemistryGeneral MedicineReversed-phase chromatographyHigh-performance liquid chromatographyAnalytical ChemistrySolventchemistry.chemical_compoundSilanolchemistryOxprenololmedicineSolventsSpectrophotometry UltravioletSodium dodecyl sulfateTriethylamineChromatography High Pressure Liquidmedicine.drugJournal of chromatographic science
researchProduct

High-performance liquid chromatographic determination of Maillard compounds in store-brand and name-brand ultra-high-temperature-treated cows' milk.

2000

Furosine and furfural products of the Maillard reaction are used as specific indicators of the effect of heating treatments on milk quality. Their contents were measured in representative samples of store- and name-brand ultra-high-temperature-treated milks using RP-HPLC with UV detection. Furosine contents ranged from 40.32 to 50.67 and from 65.48 to 310.58 mg/100 g protein in name- and store-brand milks, respectively. Of the furfurals, only hydroxymethylfurfural was detected. The free hydroxymethylfurfural contents of store-brand milks ranged from 0.22 to 1.70 mg/100 g protein. Total hydroxymethylfurfural contents ranged from 0.29 to 0.41 and from 0.72 to 2.21 mg/100 g protein, for name- …

ChromatographyHot TemperatureOrganic ChemistryFood composition dataGeneral MedicineReversed-phase chromatographyFurfuralBiochemistryHigh-performance liquid chromatographyAnalytical ChemistryMaillard Reactionchemistry.chemical_compoundMaillard reactionsymbols.namesakeMilkchemistrysymbolsAnimalsCattleSpectrophotometry UltravioletUv detectionQuantitative analysis (chemistry)HydroxymethylfurfuralChromatography High Pressure LiquidJournal of chromatography. A
researchProduct

Reliability of the retention factor estimations in liquid chromatography.

2004

The retention factor is one of the most universally used parameters in chromatography. However, large differences in the experimental retention factor values are observed when the same compound is injected in a given stationary/mobile phase system under intermediate precision conditions. Conventional protocols for estimating retention factors have problems that mainly arise from difficulties in the hold-up time measurements and the omission of the existence of extra-column times by practicing chromatographers. In the present paper, three different approaches for estimating retention factors are tested: (i) classical retention factor estimations based on the gross hold-up time, (ii) based on…

ChromatographyMicellar liquid chromatographyChemistryOrganic ChemistrySpectrophotometry UltravioletGeneral MedicineBiochemistryRetention timeReliability (statistics)Analytical ChemistryChromatography LiquidJournal of chromatography. A
researchProduct

Determination of SiO 2 in lime mud by gravimetry

1999

A simple and rapid method for the determination of SiO2 in lime mud used in current sulfate pulping practice is reported. The lime mud samples are treated three times with 2.5 mL of 6 mol/L hydrochloric acid. The samples are nearly evaporated to dryness two times and the third time to complete dryness. To determine the exact SiO2 content of the residue, it is treated with an excess of concentrated hydrofluoric acid and a little hydrochloric acid, and the silica is expelled as volatile silicon tetrafluoride. The sample treatments take about 1.5 h and the heating periods take a total of about 3.5 h. The SiO2 results were evaluated by analyzing National Institute of Standards and Technology St…

ChromatographyMineralogyHydrochloric acidRepeatabilityengineering.materialBiochemistrychemistry.chemical_compoundHydrofluoric acidchemistrySilicon tetrafluorideengineeringmedicineDrynessGravimetrySulfatemedicine.symptomLimeFresenius' Journal of Analytical Chemistry
researchProduct

Critical study of and improvements in chromatographic methods for the analysis of type B trichothecenes

2001

Various analytical methods used in the analysis of type B trichothecenes (deoxynivalenol, nivalenol, 3- and 15-acetyldeoxynivalenol) in cereals were compared and optimised in this work. These methods use either GC-electron-capture detection (ECD) of trimethylsilyl, trifluoroacetyl and heptafluorobutyryl derivatives or HPLC with UV or photodiode array detection of analytes. A new HPLC procedure using fluorescence detection prior derivatisation with coumarin-3-carbonyl chloride has been also tested. Five extraction solvents and two solid-phase extraction cartridges (silica, Florisil) plus a especial clean-up column (MycoSep 225) were compared in order to obtain the best recovery of the mycoto…

ChromatographyOrganic ChemistryExtraction (chemistry)TrichotheceneGeneral MedicineSensitivity and SpecificityBiochemistryHigh-performance liquid chromatographyAnalytical ChemistryElectron capture detectorchemistry.chemical_compoundSpectrometry FluorescenceFusariumchemistryCalibrationSpectrophotometry UltravioletSample preparationSolid phase extractionGas chromatographyEdible GrainTrichothecenesDerivatizationChromatography High Pressure LiquidJournal of Chromatography A
researchProduct