A set of indicators for arc faults detection based on low frequency harmonic analysis
2016
In this paper a novel set of indicators is presented for arc faults detection in electrical circuits. The indicators are defined starting from an experimental characterization of the arc fault phenomenon and the study of the arcing current in several test conditions, which were chosen in accordance with the UL 1699 Standard requirements. The proposed parameters are measured by means of a high resolution low frequency spectral analysis of the arcing current, which allows to achieve a good spectral resolution even with short observation windows.
Smart interface devices for distributed generation in smart grids: The case of islanding
2017
With the increasing presence of distributed generators (DGs), the implementation of a smart sensors and actuators network in distribution grids has become crucial for different monitoring, management and protection functionalities. For DGs monitoring and control, sensors and actuators are usually embedded in so-called interface devices (IDs) or interface protection systems (IPSs). Existing IDs lack in communication interfaces both to the electrical energy Distribution System Operators (DSOs) and to the DGs inverter. In this framework, the authors have developed a new ID solution and a proper communication architecture, which allow implementing new smart functionalities based on the interact…
Comparison on the use of PV systems in the vertical walls
2015
In this article the preliminary evaluation of the performance of a photovoltaic window is presented. The aim is to trace the behavior of next-generation systems, which favor architectonical integration. Three different systems have been taken into account: a dye sensitized solar cell (DSSC), blue and grey caved silicon panels. The systems can be placed behind a window or behind a wall of glass blocks.
A simplified approach for load flow analysis in MV smart grids based on LV power measurements
2017
This paper presents a simplified approach for load flow analysis in medium voltage (MV) distribution networks. It is a power summation Backward/Forward (B/F) algorithm, based on measurements of active and reactive powers at low voltage (LV) side of MV/LV distribution substations. The proposed solution allows achieving good accuracy, computational efficiency and fast convergence. In order to verify the algorithm performances, simulation studies are carried out in the case of a real test system, i.e. the distribution grid of Favignana Island (Mediterranean Sea, Italy). The compatibility between simulations results and power measurements at the MV bus bars of the generating substation shows th…
Secondary substation power line communications for medium voltage smart grids
2012
In this paper a performance analysis is carried out, in order to evaluate the possibility to employ power line communication (PLC) between secondary substations of a medium voltage (MV) distribution networks in a smart grid. The study is focused on the analysis of PLC technologies and the evaluation of the influence quantities on the communication performance in the most common case of by-pass connection at MV bus-bars of secondary substations. Different quantities have been analyzed as modulation techniques, requested bandwidth and bitrate, coupling device and system attenuation versus frequency in order to find the best solution for a reliable communication system. A complete model of a r…
Experimental investigation on PLC signal crossing of power transformers
2014
In this work the use of PLC in MV-LV networks is investigated, by means of experimental tests in the case of a two-ways MV/LV communication between two secondary substations. The two substations are connected by a MV overhead power line. Moreover each substation has a by-pass connection at MV bus-bars and a MV/LV power transformer. A ST7580 transceiver is used to inject the communication signal. The transceiver is embedded in a new interface device developed by the authors. In the paper the communication issues are introduced and some experimental tests are presented and discussed. Such tests have been carried out in the presence of voltage net, i.e. 24 kV, with the aim to verify the possib…
Uncertainty evaluation in the measurements for the electric power quality analysis
2013
The paper deals with the uncertainty estimation in the measurements performed to assess the electric power quality. In a first steps, according to the 'ISO - Guide to Expression of the Uncertainty in Measurements' all the error sources, which give a significant contribution to the combined uncertainty associated to the measurement results, are identified. Successively, in order to analyze how the errors propagate through the measurement chain, a Monte Carlo based approach is proposed. The method exploits an ad-hoc developed simulator of the measurement process, which takes into account the particular way of propagation of all the identified error sources. Eventually, with the aim of validat…
Electric Power Quality Evaluation in the Presence of Electromagnetic Emissions
2013
The measurements for the assessment of the electric power quality are often carried out in hostile electromagnetic environments. The aim of the paper is analyzing if and how both radiated and conducted electromagnetic emissions can disturb the measurement system used to quantify these disturbances. To achieve the target, an experimental approach is proposed, which, by means of a simple and fast test, allows establishing if the real electromagnetic environment, where power quality analysis is performed, can alter the measurements. © 2013 IEEE.
Experimental EMF characterization of a secondary substation
2015
This paper presents the results of the experimental EMC characterization of a new medium/low voltage (MV/LV) secondary substation, which was developed in the framework of the research project "NEW CAB ELARC". It has two MV/LV transformers, with total rated power of 1000 kVA. To perform the experimental characterization, firstly an analysis was performed of the Italian and European standards recommendations. Different approaches were highlighted and the most appropriate procedures were identified for the measurement of the magnetic fields emissions, at power systems frequency (50 Hz) in steady-state conditions. A dedicated test lab was set up for the secondary substation characterization. Th…
A PC-based wattmeter for high accuracy power measurements
2010
This paper proposes the use of a commercial data acquisition board (DAQ) connected to a common personal computer for high accuracy power measurements. In the paper the set up of the PC-based wattmeter is described and an experimental evaluation of its metrological performances is made by means of the comparison with a simultaneous coherent digital sampling wattmeter realized with two high-precision DMMs Hewlett Packard Model 3458 A. In both cases the power source is a Fluke 6100A/E electrical power standard. © 2010 IEEE.