Search results for "RILL"
showing 10 items of 1272 documents
Clinical predictors to identify paroxysmal atrial fibrillation after ischaemic stroke.
2013
Background and purpose Detection of paroxysmal atrial fibrillation (pAF) after an ischaemic cerebrovascular event is of imminent interest, because oral anticoagulation as a highly effective secondary preventive treatment is available. Whereas permanent atrial fibrillation (AF) can be detected during routine electrocardiogram (ECG), longer detection duration will detect more pAF but might be resource consuming. The current study tried to identify clinical predictors for pAF detected during long-term Holter ECG and clinical follow-up. Methods Patients with acute ischaemic stroke were prospectively investigated with an intensified algorithm to detect pAF (7-day Holter ECG, follow-up investigat…
Natural history of the Sprint Fidelis lead: survival analysis from a large single-center study.
2012
The purposes of our study were to: (1) determine lead failure rate in a large single-center cohort of Sprint Fidelis 6949 (Fidelis) leads, (2) define the risk of lead failure over time, (3) assess the impact of the Lead Integrity Alert (LIA) on lead failure presentation, and (4) identify independent predictors of Fidelis lead failure. All patients who underwent implantation of a Fidelis lead between September 2004 and July 2007 were included. Demographic, clinical, and device characteristics at the time of implant and prior to failure were collected and analyzed. A total of 971 Fidelis leads (706 men, 265 women, mean age 68.4 ± 12.8 years) were implanted. Over a mean follow-up of 46.3 month…
Prognosis of silent atrial fibrillation after acute myocardial infarction at 1-year follow-up
2014
Silent atrial fibrillation (AF), assessed by continuous ECG monitoring (CEM), has recently been shown to be common in acute myocardial infarction (AMI), and associated with higher hospital mortality. However, the long-term prognosis is still unknown. We aimed to assess 1-year prognosis in patients experiencing silent AF in AMI.All consecutive patients with AMI who were prospectively analysed by CEM during the first 48 h after admission and who survived at hospital discharge were included. Silent AF was defined as asymptomatic episodes lasting at least 30 s. Patients were followed up at 1 year for cardiovascular (CV) outcomes.Among the 737 patients analysed, 106 (14%) developed silent AF and…
Permanent Pacemaker Lead Insertion Connected to an External Pacemaker Generator for Temporary Pacing After Transcatheter Aortic Valve Implantation.
2019
Abstract Background Outcomes after transcatheter aortic valve implantation (TAVI) have been demonstrated to be at least equivalent in the short term compared to surgical valve implantation (SAVI). However, Conduction abnormalities are more common after TAVI than SAVI and the need for permanent pacemaker implantation is more common after TAVI with the currently commercially available self-expanding valves than after SAVI. Temporary pacemaker implantation may be associated with inability to ambulate, lead migration or perforation and infection. Depending on the monitoring system, some arrhythmias may not be detected. We examined the feasibility and safety of permanent pacemaker lead implantat…
Paroxysmal atrial fibrillation and high degree AV block: use of single-lead VDDR pacing with mode switching.
1998
Dual chamber rate responsive pacing incorporating a mode switching option is increasingly used in patients with chronic paroxysmal atrial fibrillation and high degree AV block. Single-lead VDDR pacemakers have rarely used for this indication. The purpose of this study was to determine their reliability of atrial sensing during atrial fibrillation, the percentage of atrial synchronous ventricular pacing, and the behavior of the sinus rate outside the phases of atrial fibrillation. We studied ten patients with a single-lead VDDR pacemaker implanted for this indication. Follow-up visits were performed at predischarge and after 1, 3, 6, 12, 18, and 24 months. During the mean follow-up period of…
Automatic detection of paroxysmal atrial fibrillation in patients with ischaemic stroke: better than routine diagnostic workup?
2016
Background and purpose Prolonged electrocardiogram (ECG) monitoring after ischaemic stroke increases the diagnostic yield of paroxysmal atrial fibrillation (pAF). In order to facilitate the additional workload involved in ECG analysis due to prolonged monitoring times, we investigated the effectiveness of pAF detection with an automated software algorithm (SA) in comparison to the routine staff-based analysis (RA) during standard stroke-unit care. Therefore, patients with acute ischaemic stroke or transitory ischaemic attack presenting with sinus rhythmus on the admission ECG and no history of atrial fibrillation were prospectively included. Methods A 24-h Holter ECG assessment was performe…
Cognitive, biochemical, and imaging profile of patients suffering from idiopathic normal pressure hydrocephalus
2011
Abstract Introduction It has still not been clearly established whether the cognitive deficits of idiopathic normal pressure hydrocephalus (iNPH) are caused by a disturbance in cerebrospinal fluid (CSF) dynamics or an underlying metabolic disturbance. Objective To identify the possible associations between biochemical markers, the neuroimaging characteristics, and cognitive deficits of patients undergoing investigations for possible iNPH. Methods A CSF sample obtained during a lumbar puncture from 10 patients with iNPH was analyzed for several biochemical markers (lactate, 8-isoprostane, vascular endothelial growth factor [VEGF], neurofilament heavy protein, glial fibrillary acidic protein,…
Hospitalization Within the First Year After Stroke
2014
Background and Purpose— This population-based study aimed to identify unplanned hospitalization within the first year after stroke to determine factors associated with it and consequences on survival. Methods— All first-ever acute strokes occurring in Dijon, France, from 2009 to 2011, were prospectively collected from a population-based registry. Demographics and clinical data, including stroke severity measured by the National Institutes of Health Stroke Scale and disability after stroke, were recorded. For each patient, the first unplanned hospitalization that occurred within 1 year after stroke was retrieved by linking data with the national French Hospital Discharge Database. Predictor…
Deterioration of organization in the first minutes of atrial fibrillation: A beat-to-beat analysis of cycle length and wave similarity
2007
Deterioration of AF Organization. Introduction: It has been recently suggested that many episodes of atrial fibrillation (AF) may be partially organized at the onset and thus more suitable for antitachycardia pacing therapy. Nevertheless, the time course of organization in the first minutes of AF has not been quantified yet. Methods and Results: Twenty episodes of paroxysmal AF were studied. Electrograms were recorded from the right atrium (RA), distal (CSd), and proximal coronary sinus (CSp). The time course of AF cycle length (AFCL) and the regularity of wave morphology (similarity index S) were beat-to-beat measured at each recording site during the first 7 minutes of AF. AFCL and S show…
Permanent left atrial pacing therapy may improve symptoms in heart failure patients with preserved ejection fraction and atrial dyssynchrony: a pilot…
2012
Aims Our group has recently shown that in some patients, heart failure with preserved ejection fraction (HFPEF) may be explained by ‘atrial dyssynchrony syndrome’ (ADS) due to interatrial conduction delay (IACD), a short left atrioventricular interval (LAVI), and increased left atrial (LA) stiffness. Our primary objective was to evaluate LA pacing therapy as a new treatment to restore left ventricular active filling in patients with no other known causes for HF than ADS. Methods and results Six patients with severe HFPEF with IACD (P wave duration >120 ms in lead II), short LAVI during electrophysiological studies ( 15), and no standard indication for a pacemaker were implanted with a lead …