Search results for "ROMA"
showing 10 items of 13919 documents
Prediction of peak shape in hydro-organic and micellar-organic liquid chromatography as a function of mobile phase composition
2007
A simple model is proposed that relates the parameters describing the peak width with the retention time, which can be easily predicted as a function of mobile phase composition. This allows the further prediction of peak shape with global errors below 5%, using a modified Gaussian model with a parabolic variance. The model is useful in the optimisation of chromatographic resolution to assess an eventual overlapping of close peaks. The dependence of peak shape with mobile phase composition was studied for mobile phases containing acetonitrile in the presence and absence of micellised surfactant (micellar-organic and hydro-organic reversed-phase liquid chromatography, RPLC). In micellar RPLC…
A comparative study of the performance of acetonitrile and methanol in the multi-linear gradient separation of proteic primary amino acids
2006
The performance of the separation of proteic primary amino acids using multi-linear gradients of acetonitrile and methanol was studied under an experimental-design basis, using an Inertsil ODS-3 column and pre-column derivatization with o-phthaldialdehyde (OPA) and N-acetyl-l-cysteine (NAC). Elution strength, peak properties, resolution, and analysis time, were examined. The optimal separation was established through modeling, using information obtained from isocratic data. By optimizing the separation with gradients of increasing complexity, acceptable resolution was possible, being glycine/threonine the critical pair. Multi-criteria decision-making (Derringer desirabilities) was applied t…
Interpretive optimisation strategy applied to the isocratic separation of phenols by reversed-phase liquid chromatography with acetonitrile–water and…
2000
An optimisation protocol is presented for the resolution of complex mixtures in isocratic RPLC with binary mobile phases of organic solvent and water, which is based on the prediction of peak position and shape of the individual compounds. A good description of the retention was achieved through the application of statistical weights to the widely used linear or quadratic relationships between the logarithm of the retention factor (log k) and the organic solvent concentration in the mobile phase. The maximisation of the product of peak purities for each compound is shown as a competitive resolution strategy versus the worst value of a selectivity parameter. Peak purities allow one to associ…
A chromatographic objective function to characterise chromatograms with unknown compounds or without standards available
2015
Abstract Getting useful chemical information from samples containing many compounds is still a challenge to analysts in liquid chromatography. The highest complexity corresponds to samples for which there is no prior knowledge about their chemical composition. Computer-based methodologies are currently considered as the most efficient tools to optimise the chromatographic resolution, and further finding the optimal separation conditions. However, most chromatographic objective functions (COFs) described in the literature to measure the resolution are based on mathematical models fitted with the information obtained from standards, and cannot be applied to samples with unknown compounds. In …
Peak half-width plots to study the effect of organic solvents on the peak performance of basic drugs in micellar liquid chromatography.
2009
The addition of the anionic surfactant sodium dodecyl sulphate (SDS) to hydro-organic mixtures of methanol, ethanol, propanol or acetonitrile with water yielded enhanced peak shape (i.e. increased efficiencies and symmetrical peaks) for a group of basic drugs (β-blockers) chromatographed with a Kromasil C18 column. The effect can be explained by the thin layer of surfactant associated to the hydrocarbon chain on the stationary phase in the presence of the organic solvents, which covers the free silanols on the siliceous support avoiding their interaction with the cationic basic drugs. These instead interact with the anionic head of the surfactant increasing their retention and allowing a mo…
Determination of free formaldehyde in cosmetics containing formaldehyde-releasing preservatives by reversed-phase dispersive liquid-liquid microextra…
2017
Abstract An analytical method for the determination of traces of formaldehyde in cosmetic products containing formaldehyde-releasing preservatives has been developed. The method is based on reversed-phase dispersive liquid–liquid microextraction (RP-DLLME), that allows the extraction of highly polar compounds, followed by liquid chromatography–ultraviolet/visible (LC–UV/vis) determination with post-column derivatization. The variables involved in the RP-DLLME process were studied to provide the best enrichment factors. Under the selected conditions, a mixture of 500 μL of acetonitrile (disperser solvent) and 50 μL of water (extraction solvent) was rapidly injected into 5 mL of toluene sampl…
Characterization of particle morphology of biochanin A molecularly imprinted polymers and their properties as a potential sorbent for solid-phase ext…
2014
Abstract Molecularly imprinted polymers (MIPs) with biochanin A as a template were obtained using a bulk polymerization with non-covalent imprinting approach. The polymers were prepared in acetonitrile as porogen, using ethylene glycol dimethacrylate (EDMA) as cross-linking agent. The synthesis, with an application of 1′,1′-azobis(cyclohexanecarbonitrile) (ACHN) as an initiator, has been performed thermally. During the synthesis process the effect of different functional monomers such as methacrylic acid (MAA), acrylamide (AA) and 4-vinylpyridine (4-VP) was investigated. The application of nitrogen sorption porosimetry, scanning electron microscopy (SEM), and Fourier transform infrared spec…
Assisted baseline subtraction in complex chromatograms using the BEADS algorithm.
2017
The data processing step of complex signals in high-performance liquid chromatography may constitute a bottleneck to obtain significant information from chromatograms. Data pre-processing should be preferably done with little (or no) user supervision, for a maximal benefit and highest speed. In this work, a tool for the configuration of a state-of-the-art baseline subtraction algorithm, called BEADS (Baseline Estimation And Denoising using Sparsity) is developed and verified. A quality criterion based on the measurement of the autocorrelation level was designed to select the most suitable working parameters to obtain the best baseline. The use of a log transformation of the signal attenuate…
Optimised procedures for the reversed-phase liquid chromatographic analysis of formulations containing tricyclic antidepressants.
2003
The chromatographic behaviour (retention, selectivity, peak shape and resolution) of seven tricyclic antidepressants (TCAs), amitryptiline, clomipramine, doxepin, imipramine, maprotiline, nortryptiline and trimipramine, was examined. Conventional unendcapped Cs and C18 columns and an endcapped XTerra MS C18 column recommended for the analysis of basic compounds were used together with acetonitrile-water and micellar sodium dodecylsulfate (SDS)-pentanol mobile phases. The two best combinations were XTerra C18/acetonitrile, which yielded the largest efficiencies and resolution, and C8/SDS-pentanol, which eliminated the peak tails that were still observed with the XTerra C18 column. Both the s…
Reversed phase liquid chromatography for the enantioseparation of local anaesthetics in polysaccharide-based stationary phases. Application to biodeg…
2020
[EN] A comprehensive study on the chiral separation of bupivacaine, mepivacaine, prilocaine and propanocaine with eight commercial polysaccharide-based chiral stationary phases (CSPs) in reversed phase conditions compatible with MS detection is performed. Methanol and acetonitrile are used as organic modifiers. Retention and resolution values obtained for each compound in the different CSPs and mobile phases are compared. The polysaccharide-based CSPs tested present different enantioselectivity towards the analytes. From the results, the experimental conditions for determining the enantiomers of bupivacaine, mepivacaine, prilocaine and propanocaine in saline aqueous samples using MS detecti…