Search results for "Radiation Dose"
showing 10 items of 44 documents
Patient centring and scan length: how inaccurate practice impacts on radiation dose in CT colonography (CTC).
2019
Objective: The aim of this study was to acknowledge errors in patients positioning in CT colonography (CTC) and their effect in radiation exposure. Materials and methods: CTC studies of a total of 199 patients coming from two different referral hospitals were retrospectively reviewed. Two parameters have been considered for the analysis: patient position in relation to gantry isocentre and scan length related to the area of interest. CTDI vol and DLP were extracted for each patient. In order to evaluate the estimated effective total dose and the dose to various organs, we used the CT-EXPO ® software version 2.2. This software provides estimates of effective dose and doses to the other vario…
Obesity Triples the Radiation Dose of Stone Protocol Computerized Tomography
2013
Patients with recurrent nephrolithiasis are often evaluated and followed with computerized tomography. Obesity is a risk factor for nephrolithiasis. We evaluated the radiation dose of computerized tomography in obese and nonobese adults.We scanned a validated, anthropomorphic male phantom according to our institutional renal stone evaluation protocol. The obese model consisted of the phantom wrapped in 2 Custom Fat Layers (CIRS, Norfolk, Virginia), which have been verified to have the same radiographic tissue density as fat. High sensitivity metal oxide semiconductor field effect transistor dosimeters were placed at 20 organ locations in the phantoms to measure organ specific radiation dose…
Radiation dose from multidetector CT studies in children: results from the first Italian nationwide survey
2014
Background Multidetector CT (MDCT) scanners have con- tributed to the widespread use of CT in paediatric imaging. However, concerns are raised for the associated radiation exposure. Very few surveys on radiation exposure from MDCT studies in children are available. Objective The aim of this study was to outline the status of radiation exposure in children from MDCT practice in Italy. Materials and methods In this retrospective multicentre study we asked Italian radiology units with an MDCT scanner with at least 16 slices to provide dosimetric and acquisition param- eters of CT examinations in three age groups (1–5, 6–10, 11– 15 years) for studies of head, chest and abdomen. The dosi- metric…
Diagnostic Performance and Radiation Dose of the EOS System to Image Enchondromatosis: A Phantom Study
2020
Background: Radiation doses and capability of EOS, conventional radiography (CR), and computed tomography (CT) to detect and measure enchondromas in a dedicated five-year-old anthropomorphic phantom were compared. Methods: To simulate enchondromas, minced pieces of chicken bone and cartilage were packed in conventional kitchen plastic foil to create ovoidal/rounded masses and randomly hung on the phantom. The phantom was imaged five times with CR, CT, and EOS, each time changing the number and position of inserts. All images were reviewed by a senior radiologist and a radiology resident. Results: EOS and CR detected all inserts in 4/5 cases (80%), while in one case 1/17 inserts was not seen…
PET Chemistry: An Introduction
2021
One major advantage of radioactivity is its extremely high sensitivity of detection. Regarding the medical applicability of radioactivity, it permits non-invasive in vivo detection of radiolabelled compounds at nano- to picomolar levels. The use of substances at such low concentrations usually precludes a physiological, toxic or immunologic response of the investigated biological system. Consequently, the considered physiological process or system is examined in an unswayed situation. Furthermore, a wide range of substances, even those which are toxic at higher concentrations, become considerable for the development of radiopharmaceuticals and use in nuclear medicine. In contrast to the wid…
Investigation of committed radiation dose rate and relationships between alkaline metals concentrations in mushroom Xerocomus badius / Badanie wchłon…
2012
Abstract The fruiting bodies of fungi sprout from mycelium are capable of accumulating significant amounts of trace elements, both metals and metalloids. Content of these elements in fruiting bodies may exceed their concentration in the substrate where fungi develop. Among the elements the radioactive nuclides are also present. In this work health risk caused by increased radioactivity dose absorbed with Xerocomus badius bay bolete consumption was estimated. In analysis concentrations of radioactive isotopes 137Cs and 40K were taken into consideration. It was found that moderate ingestion of bay bolete does not create health risk due to increased radioactive substances intake. The amount of…
Stress-first single photon emission computed myocardial perfusion imaging
2016
Background. Myocardial perfusion imaging (MPI) with single photon emission tomography (SPET) is widely used in coronary artery disease evaluation. Recently major dosimetric concerns have arisen. The aim of this study was to evaluate if a pre-test scoring system could predict the results of stress SPET MPI, thus avoiding two radionuclide injections. Methods. All consecutive patients (n=309) undergoing SPET MPI during the first 6 months of 2014 constituted the study group. The scoring system is based on these characteristics: age >65 years (1 point), diabetes (2 points), typical chest pain (2 points), congestive heart failure (3 points), abnormal ECG (4 points), male gender (4 points), and…
Efficacy of raw implementation and reduction dose protocols in CT colonoscopy: a single centre 4 years retrospective review
2015
Aims and objectives Methods and materials Results Conclusion Personal information References
Estimation of external gamma radiation dose in the area of Bory Stobrawskie forests (PL).
2011
The study assessed the radiological risks associated with the presence of natural and artificial radionuclides in the Bory Stobrawskie forests (PL). Using the conversion factors given by UNSCEAR and the measurements results of (232)Th series, (238)U series, (40)K, and (137)Cs specific activities in the 10-cm soil layer the values of absorbed dose (D) and the annual effective dose equivalent derived from terrestrial gamma radiation (E) were calculated. The calculated dose was compared with doses directly measured on the area studied.
A Preliminary Estimation of the Direct Ultraviolet Spectral Irradiance in Valencia (Spain): Comparison with Measured Values
2000
UVSPEC and SMARTS2 models have been used to estimate the UV spectral irradiance values in Valencia, Spain, and the results of these estimations have been compared with experimental measurements of direct irradiance at normal incidence obtained using an Optronic OL 754 in the 300-400 nm range. The relative RMSD and MBD parameters have been used to estimate the deviations of the modelled values with respect to the experimental values. The results indicate that the deviations are smaller when the SMARTS2 model is used with the appropriate aerosol coefficients.