Search results for "Radiograph"
showing 10 items of 830 documents
Imaging of non-glandular superficial metastases: A comparison of xeroradiography, ultrasonography and computed tomography
1989
Between January 1983 and July 1987, 1,622 cancer patients were evaluated to outline the possible applications and limits of various investigative techniques for evaluating metastases. Seventy-three cases with superficial metastases of the dermal-hypodermal (59) layers, of the muscles (11) and of other target organs (3) were included in the study. Although non-glandular superficial metastases are a relatively rare occurrence, diagnostic imaging techniques are indicated for evaluating their extent and anatomical connections. Secondary neoplasms were studied using the imaging techniques of sonography, computed tomography and xeroradiography. The diagnostic reliability of these three techniques…
Thrombosis, fracture, and percutaneous removal of a patent foramen ovale closure device 1 month after successful deployment
2010
Several different devices have been developed for the percutaneous closure of interatrial defects and patent foramen ovale. Although the implantation of these devices is both safe and effective, a number of complications, both in the early and the late follow-up, may occur. We describe a case of device fracture manifested early (1 month after implantation) with the formation of massive thrombosis on the right atrial disc. The patient was treated with anticoagulants and the device was percutaneously retrieved. Our images allowed early noninvasive therapy and emphasize the need for echocardiographic follow-up early after implantation. © 2010 Wiley-Liss, Inc.
Prevalence of carotid artery calcifications among 2,500 digital panoramic radiographs of an adult Brazilian population
2018
Background The aim of the present study was to analyze the epidemiological data of digital panoramic radiographs revealing suggestive images of carotid artery calcifications (CAC) from a Northeast Brazilian population. Material and Methods A cross-sectional retrospective study was conducted with 2,500 digital panoramic radiographs obtained from a single imaging reference center in Northeast Brazil. Images from individuals of both sexes and older than 18 years were included and those that did not cover the region of cervical vertebrae or presented low radiographic quality were excluded. Data were analyzed regarding prevalence, location (bilateral, right or left), sex, and age using the Chi-s…
Biological responses to individualized small titanium implants for the treatment of focal full-thickness knee cartilage defects in a sheep model.
2019
Abstract Background The present study aimed to evaluate the functional, radiological and histological outcome of a customized focal implant for the treatment of focal full-thickness cartilage defects in sheep. Methods The study used magnetic resonance imaging data as the basis for construction of the titanium implant using a three-dimensional printing technique. This was then placed on the medial condyle of the knee joint in eight sheep and left in place in vivo over a period of six months. Following euthanasia, the local biological response was analyzed using micro-computed tomography, light microscopy and histological evaluation (International Cartilage Repair Society (ICRS) score). The v…
Sites of sulfatation in the chondrocytes of the articular cartilage of the rabbit
1977
35S sulfate uptake by the articular cartilage chondrocytes, from biopsies of rabbit, have been studied by high resolution autoradiography. The Golgi apparatus, rough endoplasmic reticulum, cytosol, cytoplasmic membrane and extracellular space were considered as cell compartments in the quantitative analysis of the autoradiograms. The results obtained show: 1) a high activity of radiosotope incorporation in the Golgi apparatus; 2) a fast rhythm of transfer of the substances labelled in the Golgi apparatus to the cell membrane; 3) significant labelling of the rough endoplasmic reticulum, throughout the experiment. It is concluded: 1) The grains observed in the rough endoplasmic reticulum show…
Association between radiography-based subchondral bone structure and MRI-based cartilage composition in postmenopausal women with mild osteoarthritis
2016
Summary Objective Our aim was to investigate the relation between radiograph-based subchondral bone structure and cartilage composition assessed with delayed gadolinium enhanced magnetic resonance imaging of cartilage (dGEMRIC) and T 2 relaxation time. Design Ninety-three postmenopausal women (Kellgren–Lawrence grade 0: n = 13, 1: n = 26, 2: n = 54) were included. Radiograph-based bone structure was assessed using entropy of the Laplacian-based image ( E Lap ) and local binary patterns ( E LBP ), homogeneity indices of the local angles (HI Angles,mean , HI Angles,Perp , HI Angles,Paral ), and horizontal (FD Hor ) and vertical fractal dimensions (FD Ver ). Mean dGEMRIC index and T 2 relax…
Going beyond histology. Synchrotron micro-computed tomography as a methodology for biological tissue characterization: from tissue morphology to indi…
2009
Current light microscopic methods such as serial sectioning, confocal microscopy or multiphoton microscopy are severely limited in their ability to analyse rather opaque biological structures in three dimensions, while electron optical methods offer either a good three-dimensional topographic visualization (scanning electron microscopy) or high-resolution imaging of very thin samples (transmission electron microscopy). However, sample preparation commonly results in a significant alteration and the destruction of the three-dimensional integrity of the specimen. Depending on the selected photon energy, the interaction between X-rays and biological matter provides semi-transparency of the spe…
Umbilical venous catheters placement evaluation on frontal radiogram: application of a simplified flow-chart for radiology residents
2017
Background: Umbilical Venous Catheter (UVC) are commonly used in neonatal period; they can be not correctly positioned and could be associated with complications. The purpose of this article is to suggest a flow-chart to evaluate the placement of UVC, testing it in young radiologists-in-training. Method: We developed a simple flow-chart to asses, steps by step, UVC placement considering its course and tip location (ideally placed in the atriocaval junction). We tested the flow-chart impact asking to 20 residents to evaluate the placement of 10 UVC before and after they familiarized with the flow-chart and the anatomical findings of a newborn. The agreement among the 20 students was evaluate…
APPLICATION OF A FLOW CHART TO EVALUATE PLACEMENT OF UMBILICAL VENOUS CATHETERS ON FRONTAL RADIOGRAM IN RADIOLOGIST RESIDENT
2015
Aims and objectives Methods and materials Results Conclusion Personal information References
Binucleate cells in the Ehrlich ascites tumor. Autoradiographic labeling
1989
Abstract An autoradiographic study was performed on binucleate and mitotic cells in the Ehrlich ascites tumor (EAT) untreated and after treatment with 5-fluorouracil (FU). The number of binucleate cells was greater in the treated tumor than in the controls. It was also observed that the number of labeled mitoses was greater in the Fu-treated tumor. Autoradiographic labeling showed that the cells that proved to be binucleate had previously passed through S-phase; thus, these cells belonged to the proliferative compartment.