Search results for "Radiograph"

showing 10 items of 830 documents

Recommendations for standardization and phenotype definitions in genetic studies of osteoarthritis: the TREAT-OA consortium

2011

Objective: To address the need for standardization of osteoarthritis (OA) phenotypes by examining the effect of heterogeneity among symptomatic (SOA) and radiographic osteoarthritis (ROA) phenotypes. Methods: Descriptions of OA phenotypes of the 28 studies involved in the TREAT-OA consortium were collected. We investigated whether different OA definitions result in different association results by creating various hip OA definitions in one large population based cohort (the Rotterdam Study I (RSI)) and testing those for association with gender, age and body mass index using one-way ANOVA. For ROA, we standardized the hip-, knee- and hand ROA definitions and calculated prevalence's of RO…

Malenivelrikkomedicine.medical_specialtygenetiikkaBiomedical EngineeringMEDLINEdiagnostiset kriteeritOsteoarthritisbehavioral disciplines and activitiesArticleCohort Studies03 medical and health sciencesRotterdam Study0302 clinical medicineRheumatologyInternal medicineTREATOAOsteoarthritismedicinePrevalenceGeneticsHumansOrthopedics and Sports Medicine030304 developmental biologyRheumatology and Autoimmunity2. Zero hunger030203 arthritis & rheumatology0303 health sciencesAnalysis of Varianceperinnöllisyystiedebusiness.industryCase-control studyDefinitionReference Standardsmedicine.diseaseGenetics Osteoarthritis Phenotype Definition TREATOA genome-wide association radiographic hip osteoarthritis bone-mineral density knee osteoarthritis hand osteoarthritis osteoporotic fractures general-population joint involvement risk-factors susceptibilityRheumatology3. Good healthPhenotypeCase-Control Studiesdiagnostic criteriaCohortPhysical therapyFemalebusinessBody mass indexCohort study
researchProduct

Diagnostic accuracy of computed tomographic colonography for the detection of advanced neoplasia in individuals at increased risk of colorectal cance…

2009

CONTEXT: Computed tomographic (CT) colonography has been recognized as an alternative for colorectal cancer (CRC) screening in average-risk individuals, but less information is available on its performance in individuals at increased risk of CRC. OBJECTIVE: To assess the accuracy of CT colonography in detecting advanced colorectal neoplasia in asymptomatic individuals at increased risk of CRC using unblinded colonoscopy as the reference standard. DESIGN, SETTING, AND PARTICIPANTS: This was a multicenter, cross-sectional study. Individuals at increased risk of CRC due to either family history of advanced neoplasia in first-degree relatives, personal history of colorectal adenomas, or positiv…

Maleoccult blood testColorectal cancerColonoscopycancer riskprediction and forecastingGastroenterologyRisk Factorscancer diagnosisPositive predicative valueadvanced cancerMedicineFamily historycomparative studycolorectal adenomafamily historyeducation.field_of_studymedicine.diagnostic_testarticleclinical trialGeneral MedicineColonoscopyMiddle Agedpriority journalrisk factorPredictive value of testsdiagnostic accuracyFemalediagnostic valueColorectal NeoplasmsColonography Computed TomographicradiographyComputed TomographicAdultmedicine.medical_specialtySettore MED/12 - GASTROENTEROLOGIAPopulationcolorectal cancerSensitivity and SpecificityPredictive Value of TestsInternal medicineadult; advanced cancer; aged; article; cancer classification; cancer diagnosis; cancer risk; clinical trial; colonoscopy; colorectal adenoma; colorectal cancer; computed tomographic colonography; controlled clinical trial; controlled study; cross-sectional study; diagnostic accuracy; diagnostic value; family history; female; human; major clinical study; male; multicenter study; occult blood test; predictive validity; priority journal; colorectal tumor; comparative study; middle aged; prediction and forecasting; radiography; risk factor; sensitivity and specificity; Adult; Aged; Colonography Computed Tomographic; Colonoscopy; Colorectal Neoplasms; Cross-Sectional Studies; Female; Humans; Male; Middle Aged; Predictive Value of Tests; Risk Factors; Sensitivity and Specificitycross-sectional studyHumanscontrolled studyhumaneducationAgedcontrolled clinical trialbusiness.industryFecal occult bloodSigmoidoscopyColonographymedicine.diseasecancer classificationcomputed tomographic colonographymajor clinical studypredictive validitymulticenter studyCross-Sectional StudiesCT colonography colorectal cancer screeningSettore MED/36 - Diagnostica Per Immagini E Radioterapiabusinesscolorectal tumorJAMA
researchProduct

In vitro carious lesion detection on D-, E-, and F-speed radiographic films

2004

Abstract Objectives To compare the accuracy in detection of interproximal natural carious lesions in vitro between Ultraspeed (D), Ektaspeed Plus (E), and Insight (F) radiographic films. Study design Ten observers indicated on a 5-point scale their confidence in detecting an interproximal lesion in 240 surfaces (120 extracted teeth) with noncavitated carious lesions. Truth was assessed microscopically from hemisections. The areas (Az) beneath receiver operating characteristic (ROC) curves were pairwise compared and used for a 2-way analysis of variance. Results Az values were significantly correlated with observers ( P  = .002; Eta = 0.671) and film type ( P  = .003; Eta = 0.412). E differe…

Matched-Pair AnalysisRadiographic FilmsDentistryDental CariesDiagnosis DifferentialLesionConfidence IntervalsRadiography DentalmedicineHumansGeneral DentistryObserver VariationAnalysis of VarianceReceiver operating characteristicbusiness.industryX-Ray FilmConfidence intervalROC CurveOtorhinolaryngologyArea Under CurveSurgeryCarious lesionOral Surgerymedicine.symptomNuclear medicinebusinessOral Surgery, Oral Medicine, Oral Pathology, Oral Radiology, and Endodontology
researchProduct

Diagnostic Performance and Radiation Dose of the EOS System to Image Enchondromatosis: A Phantom Study

2020

Background: Radiation doses and capability of EOS, conventional radiography (CR), and computed tomography (CT) to detect and measure enchondromas in a dedicated five-year-old anthropomorphic phantom were compared. Methods: To simulate enchondromas, minced pieces of chicken bone and cartilage were packed in conventional kitchen plastic foil to create ovoidal/rounded masses and randomly hung on the phantom. The phantom was imaged five times with CR, CT, and EOS, each time changing the number and position of inserts. All images were reviewed by a senior radiologist and a radiology resident. Results: EOS and CR detected all inserts in 4/5 cases (80%), while in one case 1/17 inserts was not seen…

Materials scienceComputed tomographylcsh:TechnologyImaging phantom030218 nuclear medicine & medical imagingenchondromalcsh:Chemistry03 medical and health sciences0302 clinical medicineEnchondromatosismedicineGeneral Materials Sciencelcsh:QH301-705.5InstrumentationFluid Flow and Transfer ProcessesReproducibilitymedicine.diagnostic_testlcsh:Tbusiness.industryEOSProcess Chemistry and TechnologyRadiation doseGeneral Engineeringcomputed tomographyRepeatabilityphantommedicine.diseaseconventional radiographylcsh:QC1-999Computer Science ApplicationsConventional radiographylcsh:Biology (General)lcsh:QD1-999lcsh:TA1-2040Anthropomorphic phantomlcsh:Engineering (General). Civil engineering (General)Nuclear medicinebusinessradiation doselcsh:Physics030217 neurology & neurosurgeryApplied Sciences
researchProduct

Comparative study of the radiopacity of resin cements used in aesthetic dentistry

2015

PURPOSE. The aim of this study was to compare the radiopacity of 6 modern resin cements with that of human enamel and dentine using the Digora digital radiography system, to verify whether they meet the requirements of ANSI/ADA specification no. 27/1993 and the ISO 4049/2000 standard and assess whether their radiopacity is influenced by the thickness of the cement employed. MATERIALS AND METHODS. Three 3-thickness samples (0.5, 1 and 1.5 mm) were fabricated for each material. The individual cement samples were radiographed on the CCD sensor next to the aluminium wedge and the tooth samples. Five radiographs were made of each sample and therefore five readings of radiographic density were ta…

Materials scienceRadiodensitymedicine.medical_treatmentDentistryLuting cement03 medical and health sciences0302 clinical medicinestomatognathic systemRadiopacitymedicineDentinDentistry (miscellaneous)Resin cementResin cementDigital radiographyCementEnamel paintbusiness.industry030206 dentistrymedicine.anatomical_structurevisual_artvisual_art.visual_art_mediumOriginal ArticleVeneerOral Surgerybusiness030217 neurology & neurosurgeryThe Journal of Advanced Prosthodontics
researchProduct

Mathematical analysis of projection errors in “paralleling technique” with respect to implant geometry

2001

Abstract: “Standardized” radiographs acquired in paralleling technique serve for monitoring of marginal bone levels around endosseous implants. Under clinical conditions, parallel adjustment of the film to the implant is beset with great difficulties. A mathematical model matching clinical conditions was developed to evaluate projection geometry within an interval of clinically relevant angulations (± 10° from parallel position). Radiographs of two implants (Frialit 2, Friadent AG, Mannheim, Germany; Implant No. 1: ∅ 3.8 mm, length 10 mm; Implant No. 2: ∅ 6.5 mm, length 13 mm) were separately produced per angulation (2° increments) at one focus-object distance (FO=322.9 mm). Implant images …

Materials sciencebusiness.industryRadiographyMean valueVertical edgeParalleling techniqueMagnificationGeometryImplantOral SurgeryBone levelProjection (set theory)businessClinical Oral Implants Research
researchProduct

Experimentelle In-vitro-Studie zur Evaluierung eines elektronischen Detektors für die digitale Radiographie

2004

Purpose: To evaluate the contrast-detail performance of a flat-panel detector system, we performed a comparative study of this flat-panel system versus storage phosphor and conventional screen-film systems. Materials and Methods: Bone models made of human humeri were prepared with foreign bodies, fracture lines and drilled holes to create artificial fractures, osteolyses or metastases. Immersed in a water bath, hard copy images of these models were acquired with the same exposure dose (55 kV; 3.2 mAs) on the flat-panel detector, two state-of-the-art storage phosphor systems (PCR®, ADC®) and two conventional screen-film systems (Insight®, T-Mat®). Using a standardized protocol with a 4-point…

Materials sciencebusiness.industryRadiographyStorage phosphorDetectorRadiology Nuclear Medicine and imagingRadiographic Image EnhancementNuclear medicinebusinessForeign BodiesImaging phantomFlat panel detectorDigital radiographyRöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren
researchProduct

Roentgenographic in vitro investigation of frequency and location of curvatures in human maxillary premolars.

2006

The aim of this study was to determine the location of the root canal curvature and measure the distance from the CEJ to the first curvature using in vitro methods. Extracted maxillary premolars (n = 358) were fixed and digitally radiographed using the parallel technique. Excluded from further analysis were teeth with root caries, artificial crowns, extensive fillings, or endodontic treatments. The results were descriptively analyzed and the cumulative frequencies were calculated. The median values of the distance between CEJ and first curvature were for the first right premolars 8.4 mm (buccal) and 8.5 mm (palatal), for the first left premolars 9.1 mm (buccal) and 8.9 mm (palatal). The med…

Materials sciencebusiness.industryRoot canalDentistryRoot canal morphologyCurvaturePost insertionStatistics NonparametricRadiographymedicine.anatomical_structurestomatognathic systemotorhinolaryngologic diseasesmedicineMaxillaHumansOdontometryBicuspidDental Pulp CavityTooth RootbusinessGeneral DentistryRoot cariesJournal of endodontics
researchProduct

Association between mandibular second molars calcification stages in the panoramic images and cervical vertebral maturity in the lateral cephalometri…

2019

Background Determination of maturation and evaluation of growth potential is extremely important in clinical orthodontics. The purpose of this study was to evaluate the diagnostic performance of the mandibular second molar calcification stages for identification of growth phases. Material and Methods In this cross-sectional descriptive study, samples were derived from panoramic radiographs and lateral cephalograms of 125 subjects (61 males and 64 females) with age ranging from 8 to 17 years and estimates of dental maturity (Demirjian Index [DI]) and skeletal maturity (Cervical vertebral maturation indicators CVMI]) were made. Correlations between DI and CVMI were shown by Spearman's correla…

Maturity (geology)Orthodonticsbusiness.industryRadiographyResearchLateral cephalogramsOrthodontics030206 dentistrySkeletal maturitymedicine.disease:CIENCIAS MÉDICAS [UNESCO]030218 nuclear medicine & medical imagingMandibular second molar03 medical and health sciences0302 clinical medicinestomatognathic systemUNESCO::CIENCIAS MÉDICASPost-pubertalMedicinebusinessGeneral DentistryDental maturityCalcificationJournal of clinical and experimental dentistry
researchProduct

Endodontic management of type II dens invaginatus with open apex and large periradicular lesion using the XP-endo Finisher : a case report

2018

Dens invaginatus (DI) represents an endodontic challenge because of its complex root canal morphology. This case report presents the clinical management of a 22-year-old woman with type II DI in right maxillary lateral incisor with a painful swelling. Pulp testing revealed no response with the tooth. Type II DI with open apex and large periradicular lesion was seen on radiograph. The treatment was planned by using cone-beam computed tomography (CBCT) imaging. Canal treatment was completed in two appointments with the aid of a dental operating microscope. In the first appointment, the internal anatomy was modified using an ultrasonic tip, and chemo-mechanical preparation was performed using …

Maxillary lateral incisorMineral trioxide aggregateCone beam computed tomographybusiness.industryRadiographyDentistryCase Report030206 dentistry:CIENCIAS MÉDICAS [UNESCO]medicine.diseaseOperative Dentistry and EndodonticsLesion03 medical and health sciencesDens invaginatusstomatognathic diseases0302 clinical medicinestomatognathic system030220 oncology & carcinogenesisUNESCO::CIENCIAS MÉDICASMedicineApexificationPulp (tooth)medicine.symptombusinessGeneral Dentistry
researchProduct