Search results for "Radiographic Image Enhancement"
showing 10 items of 41 documents
Going beyond histology. Synchrotron micro-computed tomography as a methodology for biological tissue characterization: from tissue morphology to indi…
2009
Current light microscopic methods such as serial sectioning, confocal microscopy or multiphoton microscopy are severely limited in their ability to analyse rather opaque biological structures in three dimensions, while electron optical methods offer either a good three-dimensional topographic visualization (scanning electron microscopy) or high-resolution imaging of very thin samples (transmission electron microscopy). However, sample preparation commonly results in a significant alteration and the destruction of the three-dimensional integrity of the specimen. Depending on the selected photon energy, the interaction between X-rays and biological matter provides semi-transparency of the spe…
Simple computation of the approximated modulation transfer function (MTF) using spreadsheet-software: method and evaluation in five maxillofacial CBC…
2019
OBJECTIVES: To develop a simple way to compute the approximated modulation transfer function (MTF) manually using conventional spreadsheet software. METHODS: Basing on an edge-image a method was developed, facilitating computation of the edge spread and line spread function in open-source spreadsheet software (Gnumeric; http://projects.gnome.org/gnumeric/downloads.shtml). By means of the integrated fast Fourier transformation Fourier coefficients are obtained from the line spread function which can then be plotted vs spatial frequency to obtain MTF-plots. For the experimental evaluation an edge test object was exposed in five commercial CBCT devices for maxillofacial applications. RESULTS: …
Mammographic images segmentation based on chaotic map clustering algorithm
2013
Background: This work investigates the applicability of a novel clustering approach to the segmentation of mammographic digital images. The chaotic map clustering algorithm is used to group together similar subsets of image pixels resulting in a medically meaningful partition of the mammography. Methods: The image is divided into pixels subsets characterized by a set of conveniently chosen features and each of the corresponding points in the feature space is associated to a map. A mutual coupling strength between the maps depending on the associated distance between feature space points is subsequently introduced. On the system of maps, the simulated evolution through chaotic dynamics leads…
Anatomical variants and anomalies of the coronary tree studied with MDCT coronary angiography
2010
Le anomalie delle arterie coronariche sono presenti alla nascita nella maggior parte dei casi asintomatiche ma possono manifestarsi con sintomatologia severa quale angina pectoris o addirittura l’arresto cardiaco. L’angiografia coronarica mediante tomografia computerizzata multistrato (TCMS) permette, tramite ricostruzioni multiplanari secondo piani curvilinei e riformattazioni 3D, la visualizzazione dell’albero coronarico e delle sue varianti ed anomalie in maniera non invasiva, fornendo migliore e più accurata alternativa alla angiografia coronarica (AC). Lo scopo di questo pictorial consiste nella descrizione mediante immagini TCMS con ricostruzioni multiplanari e 3D delle principali var…
A completely automated CAD system for mass detection in a large mammographic database.
2006
Mass localization plays a crucial role in computer-aided detection (CAD) systems for the classification of suspicious regions in mammograms. In this article we present a completely automated classification system for the detection of masses in digitized mammographic images. The tool system we discuss consists in three processing levels: (a) Image segmentation for the localization of regions of interest (ROIs). This step relies on an iterative dynamical threshold algorithm able to select iso-intensity closed contours around gray level maxima of the mammogram. (b) ROI characterization by means of textural features computed from the gray tone spatial dependence matrix (GTSDM), containing secon…
Coronary artery anomalies: incidence, pathophysiology, clinical relevance and role of diagnostic imaging
2006
Conventional coronary angiography is the gold standard for the diagnosis of coronary artery anomalies. Coronary anomalies are relatively rare findings in patients undergoing conventional coronary angiography for suspected obstructive coronary artery disease. Recently, the increasing performance of diagnostic techniques, such as electron beam tomography (EBT), magnetic resonance (MR) and, more recently, multislice computed tomography (MSCT), has enabled their application to cardiac imaging. MSCT, in particular, has a prominent role in coronary imaging due to its spatial and temporal resolution and three-dimensional capabilities. We report the incidence and pathophysiology of coronary artery …
Imaging Evaluation of Facial Complex Strut Fractures
2012
High-resolution multidetector computed tomography with multiplanar reformations and 3-D postprocessing often provides the detail necessary for preoperative assessment of facial injuries. Maxillofacial fractures are classified in the following manner: upper face fractures, midface fractures (the most frequent), Le Fort fractures, and lower face or mandible fractures. The facial skeleton is a framework of vertical and horizontal buttresses that ensures a better resistance to trauma, but serves also as reference for maxillofacial surgery to restore facial size and shape. Radiologists should know how to diagnose and report the main types of facial fracture.
Diffusion equations with negentropy applied to denoise mammographic images.
2006
Mammography is a radiographic technique used for the detection of breast lesions. The analysis of the digital image normally requires a previous application of filters as a preprocessing step to reduce the noise level of the image, while preserving important details to carry out a suitable diagnostic. In the literature, there are a large amount of denoising techniques applied to different medical images. In this work we have studied the performance of a diffusive filter with a stopping condition based on the statistical concept of negentropy, applied to denoise mammographic images. The negentropy has been succesfully prove with other denoising methods as independent component analysis by th…
Prevalence of coronary artery intramyocardial course in a large population of clinical patients detected by multislice computed tomography coronary a…
2008
Background: Intramyocardial course, an inborn coronary anomaly, is defined as a segment of a major epicardial coronary artery that runs intramurally through the myocardium; in particular, we distinguish myocardial bridging, in which the vessel returns to an epicardial position after the muscle bridge, and intramyocardial course, which is described as a vessel running and ending in the myocardium. Purpose: To evaluate the prevalence of myocardial bridging and intramyocardial course of coronary arteries as defined by multidetector computed tomography (MDCT) angiography. Material and Methods: The study population consisted of 242 consecutive patients (211 men, 31 women; mean age 59±6 years) w…
Evaluation of intraindividual contrast enhancement variability for determining the maximum achievable consistency in CT
2019
OBJECTIVE. The purpose of this study was to quantify temporal variability in vascular and parenchymal enhancement within the same patient and to determine technique-related factors contributing to this variability. MATERIALS AND METHODS. We identified 100 patients who underwent four CT scans within 12 months with identical acquisition and contrast injection parameters. Enhancement was recorded in the abdominal aorta, main portal vein, liver parenchyma, and subcutaneous fat. Patient demographic and body habitus data were recorded. Injection-related factors were recorded including delay time from contrast injection to image acquisition. All pairwise differences in enhancement within each pati…