Search results for "Radiographic"

showing 10 items of 99 documents

MDCT and virtual angioscopy in spontaneous aortocaval fistula

2007

Aortocaval fistula is a rare, less than 1%, but life threatening complication, of abdominal aortic aneurysm. Mortality is high but prompt recognition of the fistula can reduce mortality rate. The multidetector row CT (MDCT) findings in a 69-year-old patient with a complex medical history characterized by previous episodes of myocardial ischemia, is reported. MDCT shows an early homogeneous enhancement of the inferior vena cava, slightly dilated at the liver level and markedly narrowed above the renal vein due to aneurysm compression. The patient underwent to emergency laparotomy but died during surgery for cardiac arrest. MDCT allows a prompt recognition of the fistula and different compute…

Malemedicine.medical_specialtymedicine.medical_treatmentFistulaAngioscopyVena Cava InferiorInferior vena cavaAortographyAortic aneurysmUser-Computer InterfaceAneurysmFatal OutcomeImaging Three-DimensionalcavaLaparotomymedicineHumansfistulaRadiology Nuclear Medicine and imagingcardiovascular diseasesAgedMDCT angioscopymedicine.diagnostic_testbusiness.industryvirtual angioscopyPhlebographymedicine.diseaseAngioscopyAbdominal aortic aneurysmaortamultidetector row ctmedicine.veinArteriovenous Fistulacardiovascular systemRadiographic Image Interpretation Computer-AssistedRadiologyRenal veinCardiology and Cardiovascular MedicinebusinessTomography X-Ray ComputedVascular Surgical Proceduresaorta; cava; fistula; multidetector row ct; virtual angioscopyAortic Aneurysm Abdominal
researchProduct

Tako-tsubo cardiomyopathy and microcirculation.

2010

Takotsubo cardiomyopathy was described for the first time in Japan in the 1990s. It is very similar to the ischemic cardiopathy both for clinical and instrumental characteristics. His peculiarity is an alteration of the ventricular contraction mechanism with hypo-akinesis of the apex and lateral segments of the left ventricle, associated with hyper-kinesis of the heart base which is responsible for the typical echocardiographic aspect of a cruet during the systole. However, the etiology of this cardiomyopathy is still unknown despite the fact that numerous hypothesis have been made. A single study of 16 patients proved multivasal damage by a BLASH SCORE analysis of the coronary radiography.…

Malemedicine.medical_specialtytako-tsubo cardiomyopathyCardiomyopathycoronary microcirculation; takotsubo; timi frame countHemodynamicsHealth InformaticsAnterior Descending Coronary ArteryCritical Care and Intensive Care MedicineCoronary AngiographyMicrocirculationTakotsubo CardiomyopathyInternal medicinemedicine.arteryCoronary CirculationMedicineHumansAgedbusiness.industryMicrocirculationmedicine.diseaseStenosisAnesthesiology and Pain Medicinemedicine.anatomical_structureRight coronary arteryCardiologyRadiographic Image Interpretation Computer-AssistedFemalebusinessTIMIBlood Flow VelocityArteryJournal of clinical monitoring and computing
researchProduct

Recommendations for standardization and phenotype definitions in genetic studies of osteoarthritis: the TREAT-OA consortium

2011

Objective: To address the need for standardization of osteoarthritis (OA) phenotypes by examining the effect of heterogeneity among symptomatic (SOA) and radiographic osteoarthritis (ROA) phenotypes. Methods: Descriptions of OA phenotypes of the 28 studies involved in the TREAT-OA consortium were collected. We investigated whether different OA definitions result in different association results by creating various hip OA definitions in one large population based cohort (the Rotterdam Study I (RSI)) and testing those for association with gender, age and body mass index using one-way ANOVA. For ROA, we standardized the hip-, knee- and hand ROA definitions and calculated prevalence's of RO…

Malenivelrikkomedicine.medical_specialtygenetiikkaBiomedical EngineeringMEDLINEdiagnostiset kriteeritOsteoarthritisbehavioral disciplines and activitiesArticleCohort Studies03 medical and health sciencesRotterdam Study0302 clinical medicineRheumatologyInternal medicineTREATOAOsteoarthritismedicinePrevalenceGeneticsHumansOrthopedics and Sports Medicine030304 developmental biologyRheumatology and Autoimmunity2. Zero hunger030203 arthritis & rheumatology0303 health sciencesAnalysis of Varianceperinnöllisyystiedebusiness.industryCase-control studyDefinitionReference Standardsmedicine.diseaseGenetics Osteoarthritis Phenotype Definition TREATOA genome-wide association radiographic hip osteoarthritis bone-mineral density knee osteoarthritis hand osteoarthritis osteoporotic fractures general-population joint involvement risk-factors susceptibilityRheumatology3. Good healthPhenotypeCase-Control Studiesdiagnostic criteriaCohortPhysical therapyFemalebusinessBody mass indexCohort study
researchProduct

In vitro carious lesion detection on D-, E-, and F-speed radiographic films

2004

Abstract Objectives To compare the accuracy in detection of interproximal natural carious lesions in vitro between Ultraspeed (D), Ektaspeed Plus (E), and Insight (F) radiographic films. Study design Ten observers indicated on a 5-point scale their confidence in detecting an interproximal lesion in 240 surfaces (120 extracted teeth) with noncavitated carious lesions. Truth was assessed microscopically from hemisections. The areas (Az) beneath receiver operating characteristic (ROC) curves were pairwise compared and used for a 2-way analysis of variance. Results Az values were significantly correlated with observers ( P  = .002; Eta = 0.671) and film type ( P  = .003; Eta = 0.412). E differe…

Matched-Pair AnalysisRadiographic FilmsDentistryDental CariesDiagnosis DifferentialLesionConfidence IntervalsRadiography DentalmedicineHumansGeneral DentistryObserver VariationAnalysis of VarianceReceiver operating characteristicbusiness.industryX-Ray FilmConfidence intervalROC CurveOtorhinolaryngologyArea Under CurveSurgeryCarious lesionOral Surgerymedicine.symptomNuclear medicinebusinessOral Surgery, Oral Medicine, Oral Pathology, Oral Radiology, and Endodontology
researchProduct

Experimentelle In-vitro-Studie zur Evaluierung eines elektronischen Detektors für die digitale Radiographie

2004

Purpose: To evaluate the contrast-detail performance of a flat-panel detector system, we performed a comparative study of this flat-panel system versus storage phosphor and conventional screen-film systems. Materials and Methods: Bone models made of human humeri were prepared with foreign bodies, fracture lines and drilled holes to create artificial fractures, osteolyses or metastases. Immersed in a water bath, hard copy images of these models were acquired with the same exposure dose (55 kV; 3.2 mAs) on the flat-panel detector, two state-of-the-art storage phosphor systems (PCR®, ADC®) and two conventional screen-film systems (Insight®, T-Mat®). Using a standardized protocol with a 4-point…

Materials sciencebusiness.industryRadiographyStorage phosphorDetectorRadiology Nuclear Medicine and imagingRadiographic Image EnhancementNuclear medicinebusinessForeign BodiesImaging phantomFlat panel detectorDigital radiographyRöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren
researchProduct

Advantages of fitting contrast curves using logistic function: a technical note.

2013

Objective The aim of this article is to demonstrate how the contrast properties of an imaging system can be ideally fitted with the use of stripe patterns and the logistic function. Study Design Stripe patterns with defined amounts of line pairs (lp/mm) per mm (10-20 lp/mm) were recorded with the use of digital photostimulable storage phosphor. Scan data and normalized image data were analyzed with the use of ImageJ and MatLab to calculate different contrast curves. Results For original scan data, the goodness of fit was 0.0000019 (sum of squared error [SSE]). The R-square was 0.9998. For normalized data the goodness of fit was 0.0007 (SSE) and the R-square 0.998. An amount of 50% contrast …

Mean squared errorComputer scienceContrast (statistics)Image processingRadiography Dental DigitalPathology and Forensic MedicineRadiographic Image EnhancementLogistic ModelsGoodness of fitStatisticsLine (geometry)Image Processing Computer-AssistedHumansRadiology Nuclear Medicine and imagingDentistry (miscellaneous)SurgeryRadiographic Image EnhancementX-Ray Intensifying ScreensOral SurgeryLogistic functionMATLABcomputerAlgorithmAlgorithmscomputer.programming_languageOral surgery, oral medicine, oral pathology and oral radiology
researchProduct

Stafne bone defects radiographic features in panoramic radiographs: Assessment of 91 cases.

2018

Background To evaluate 91 cases of Stafne bone defect (SBD) in panoramic radiographs (PR) to determine the prevalence of different SBD variants, considering age, gender, and side. Additionally, to assess the most frequent imaging features of SBD. Material and Methods Participant data were collected from 91 SBD cases with PR imaging. First, SBDs were classified according to their location, as anterior, posterior, or ramus variant. SBD imaging features were classified according to radiographic imaging findings, assessing margins, degree of internal radiolucency, shape, topographic relationship between the defect and mandibular border, location of the defect according to mandibular teeth, and …

MolarAdultMalePanoramic radiographRadiographic imagingRadiographyRadiodensityMandibular canalMandible03 medical and health sciences0302 clinical medicinestomatognathic systemRadiography PanoramicmedicineBone CystsHumansGeneral DentistryAgedOrthodonticsAged 80 and overOral Medicine and Pathologybusiness.industryResearchMandible030206 dentistryMiddle Aged:CIENCIAS MÉDICAS [UNESCO]medicine.anatomical_structureOtorhinolaryngology030220 oncology & carcinogenesisUNESCO::CIENCIAS MÉDICASSurgeryFemaleDifferential diagnosisbusinessMedicina oral, patologia oral y cirugia bucal
researchProduct

Movement evaluation of overerupted upper molars with absolute anchorage: an in-vitro study.

2010

Introduction: The overeruption of upper molars due to the premature loss of antagonist teeth can be treated with the help of miniscrews. The aim of this study was to evaluate the movement of a typodont molar according to the biomechanical approach used with miniscrews. Study design: The study was conducted with four plaster models filled with typodont wax. In each model we used one absolute anchorage on the palatal side and another on the buccal side in different positions, thus generating four different biomechanical systems. A force of 150 g was applied to each side of the resin tooth. Periapical radiographs were taken preintrusion and immediately after completion of the intrusion. Photog…

MolarDental prosthesisTooth Movement TechniquesRadiographic FilmsBone ScrewsDentistryIn Vitro Techniquesstomatognathic systemOcclusal planemedicineMaxillaOrthodontic Anchorage ProceduresIn vitro studyGeneral DentistryTypodontMovement (music)business.industryDent molar:CIENCIAS MÉDICAS [UNESCO]Pròtesis dentalsMolarSagittal planemedicine.anatomical_structureOtorhinolaryngologyUNESCO::CIENCIAS MÉDICASSurgeryOvereruptionbusinessGeologyMedicina oral, patologia oral y cirugia bucal
researchProduct

Outcomes After Chevron Osteotomy with and Without Additional Akin Osteotomy: A Retrospective Comparative Study

2023

Abstract Background Chevron osteotomy is one of the most common approaches to hallux valgus corrective surgery. This procedure is often combined with Akin osteotomy of the proximal phalanx of the hallux. There are no definitive guidelines specifying the indications for a given osteotomy technique nor data on postoperative loss of correction or the effect of the type of first-ray surgery on the development of adjacent-joint arthritis. The aim of this study was to assess radiographic treatment outcomes via chevron osteotomy with and without Akin osteotomy. Methods The study evaluated 117 patients treated in the period 2016–2019. Ninety-nine of those patients underwent distal chevron osteotomy…

Orthopedics and Sports MedicineRadiographic · Hallux valgus · Adjacent-joint arthritis · Chevron osteotomy · Akin osteotomy · ForefootIndian Journal of Orthopaedics
researchProduct

Perspectives in Clinical Hemorheology and Microcirculation: Review of the Conference of the German Society for Clinical Microcirculation and Hemorheo…

2011

During the 29th conference of the German Society for Clinical Microcirculation and Hemorheology – held in the Freie Universitat Berlin a broad range of different topics of experimental and clinical studies in the field were presented. A special spotlight was dedicated to the Conference President’s (Prof. Dr. J. Plendl, Head of the Department of Veterinary Anatomy) scientific area “Anatomical and Experimental Microcirculation” [5, 6, 9, 13]. Of special interest were the angiogenetic studies: Examinations of the influence of PDGF-BB on adipose-tissue derived stem cells and how these influence angiogenesis [9] and the angiogenesis and healing with non-shrinking, fast degradable PLGA/CaP scaffo…

Pathologymedicine.medical_specialtyRadiographic contrast mediaEndotheliumPhysiologybusiness.industryAngiogenesisMesenchymal stem cellAortic occlusionHematologyMicrocirculationmedicine.anatomical_structurePhysiology (medical)OcclusionMedicineHemorheologyCardiology and Cardiovascular MedicinebusinessClinical Hemorheology and Microcirculation
researchProduct