Energy loss measurement of protons in liquid water
2011
The proton stopping power of liquid water was, for the first time, measured in the energy range 4.7-15.2 MeV. The proton energies were determined by the time-of-flight transmission technique with the microchannel plate detectors, which were especially developed for timing applications. The results are compared to the literature values (from ICRU Report 49 (1993) and Janni's tabulation (1982 At. Data Nucl. Data Tables 27 147-339)) which are based on Bethe's formula and an agreement is found within the experimental uncertainty of 4.6%. Thus, earlier reported discrepancy between the experimental and literature stopping power values at lower energies was not observed at the energies considered …
Dosimetric characteristics of backscattered electrons in lead.
2000
In electron beam therapy, tissue overdose due to electrons backscattered from lead has been profusely studied. To quantify this dose enhancement effect, an electron backscatter factor (EBF) was defined as the ratio of dose at the tissue-inhomogeneity interface with and without the scatterer present. The dependence of the EBF on energy at the scatterer surface is not well known for energies lower than 3 MeV which is the most frequent clinical situation. In this work, we have done Monte Carlo calculations with the GEANT code to study EBF in lead at this energy range. The applicability of this code and the developed procedure for dose estimation has been experimentally verified. The dependence…
Dosimetry characteristics of the Plus and 12i Gammamed PDR 192Ir sources.
2001
In this study a complete set of dosimetric data for the Plus and 12i Gammamed PDR (pulsed dose rate) 192 Ir sources is presented. These data have been calculated using the Monte Carlo simulation code GEANT3. Absolute dose rate distributions in water around these sources were calculated and are presented in form of conventional two dimensional (2D) Cartesian look-up tables. All dosimetric quantities recommended by the AAPM Task Group 43 report have been also calculated. These quantities are dose rate constant, radial dose function, anisotropy function and anisotropy factor. The dose rate distribution of the 12i source was compared with the corresponding data for the microselectron PDR source…
A Monte Carlo investigation of the dosimetric characteristics of the CSM11 137Cs source from CIS
2000
The purpose of this study is to calculate basic dosimetry data for a CSM11 low dose rate 137Cs source in water. This source is widely used in afterloadable dome cylinders designed to homogeneously irradiate the vaginal cuff alone or additional areas of the vagina in hysterectomized patients. In this study, the Monte Carlo simulation code GEANT, incorporating in detail source geometry, is used to investigate the dosimetric characteristics of the source. The calculated data were analyzed using a fitting procedure that is described in detail. Absolute dose rate distributions in water were calculated around this source and are presented as conventional 2D Cartesian lookup tables (classically al…
Dosimetric characteristics of the CDC-type miniature cylindrical 137Cs brachytherapy sources
2002
The low dose rate CDC-type miniature cylindrical 137 Cs sources are available, with one or three active beads, for use in source trains in automatic and manual afterloading systems for gynecological brachytherapy. Absolute dose rate distributions in water have been calculated around these sources using the Monte CarloGEANT3 code and they are presented as conventional two-dimensional Cartesian lookup tables. The AAPM Task Group 43 formalism for dose calculation has been also applied. The dose rate constant obtained for the one bead source is Λ=1.113±0.003 cGyh −1 U −1 , and the value for the three bead source is Λ=1.103±0.003 cGyh −1 U −1 . Finally, for the treatment planning systems based o…
Passive Polarimetric Imaging
2014
Passive electro-optical polarimetric imaging is a form of remote sensing in which the properties associated with electromagnetic field orientation are exploited as a means to discriminate between objects in an extended scene. The purpose of this chapter is to introduce some fundamental concepts in the science of imaging polarimetry. These concepts include the Stokes-Mueller description of polarized light, the physical mechanisms that contribute to polarimetric image contrast, a mathematical description of several polarimetric imaging systems, and an example target detection algorithm. Polarimetric image contrast is discussed in terms of reflected, emitted, and scattered light. Special empha…
Monte Carlo dosimetric characterization of the Cs-137 selectron/LDR source: evaluation of applicator attenuation and superposition approximation effe…
2004
The purpose of this study is to calculate the dose rate distribution for the Amersham Cs-137 pellet source used in brachytherapy with the Selectron low-dose-rate remote afterloading system in gynaecological applications using the Monte Carlo code GEANT4. The absolute dose rate distribution for the pellet source was obtained and presented as a one-dimensional absolute dose rate table as well as in the Task Group 43 dose-calculation formalism. In this study, excellent agreement was found between the point source theoretical model using fitted polynomial values and Monte Carlo calculations of the dose rate distribution for the pellet source. A comparison study was also made between the dose ra…
A two-dimensional liquid-filled ionization chamber array prototype for small-field verification: characterization and first clinical tests.
2012
In this work we present the design, characterization and first clinical tests of an in-house developed two-dimensional liquid-filled ionization chamber prototype for the verification of small radiotherapy fields and treatments containing such small fields as in radiosurgery, which consists of 2 mm × 2 mm pixels arranged on a 16×8 rectangular grid. The ionization medium is isooctane. The characterization of the device included the study of depth, field-size and dose-rate dependences, which are sufficiently moderate for a good operation at therapy radiation levels. However, the detector presents an important anisotropic response, up to ≃ 12% for front versus near-lateral incidence, which can …
Technical note: Monte-Carlo dosimetry of the HDR 12i and Plus 192Ir sources.
2001
In this study a complete set of dosimetric data for the GammaMed high dose rate (HDR) 12i and Plus 192 Ir sources are presented. These data have been calculated by means of the Monte Carlo simulation code GEANT3. Absolute dose rate distributions in water are presented as conventional two dimensional (2D) Cartesian look-up tables, and in the TG43 formalism.
A simple equation for determining sea surface emissivity in the 3–15 µm region
2009
The high level of accuracy demanded for the sea surface temperature retrieval from infrared data requires an accurate determination of directional sea surface emissivity (SSE). Previous models have permitted calculating SSEs using a physical characterization of sea surface roughness and emission. However, these result in complex equations, and make an operational application difficult. This paper presents a simple SSE algorithm based on a parametrization of one of these models, which was selected as a reference since it reproduces SSE experimental data to a reasonable level of accuracy. The parametrization provides the SSE variation with observation angle and wind speed from a given nadir S…