Search results for "Radiometry"
showing 10 items of 170 documents
Radiation exposure in CT-guided interventions.
2013
To investigate radiation exposure in computed tomography (CT)-guided interventions, to establish reference levels for exposure, and to discuss strategies for dose reduction.We analyzed 1576 consecutive CT-guided procedures in 1284 patients performed over 4.5 years, including drainage placements; biopsies of different organs; radiofrequency and microwave ablations (RFA/MWA) of liver, bone, and lung tumors; pain blockages, and vertebroplasties. Data were analyzed with respect to scanner settings, overall radiation doses, and individual doses of planning CT series, CT intervention, and control CT series.Eighty-five percent of the total radiation dose was applied during the pre- and post-interv…
Uncertainty on radiation doses estimated by biological and retrospective physical methods
2018
International audience; Biological and physical retrospective dosimetry are recognised as key techniques to provide individual estimates of dose following unplanned exposures to ionising radiation. Whilst there has been a relatively large amount of recent development in the biological and physical procedures, development of statistical analysis techniques has failed to keep pace. The aim of this paper is to review the current state of the art in uncertainty analysis techniques across the 'EURADOS Working Group 10- Retrospective dosimetry' members, to give concrete examples of implementation of the techniques recommended in the international standards, and to further promote the use of Monte…
EPR dosimetry intercomparison using smart phone touch screen glass
2014
International audience; This paper presents the results of an interlaboratory comparison of retrospective dosimetry using the electron paramagnetic resonance method. The test material used in this exercise was glass coming from the touch screens of smart phones that might be used as fortuitous dosimeters in a large-scale radiological incident. There were 13 participants to whom samples were dispatched, and 11 laboratories reported results. The participants received five calibration samples (0, 0.8, 2, 4, and 10 Gy) and four blindly irradiated samples (0, 0.9, 1.3, and 3.3 Gy). Participants were divided into two groups: for group A (formed by three participants), samples came from a homogene…
Radiation-induced changes in levels of selected proteins in peripheral blood serum of breast cancer patients as a potential triage biodosimeter for l…
2014
The threat of a large scale radiological emergency, where thousands of people may require fast biological dosimetry for the purpose of triage, makes it necessary to search for new, high throughput biological dosimeters. The authors tested an assay based on the quantitative analysis of selected proteins in peripheral blood serum. They were particularly interested in testing proteins that are specific to irradiation of skin, as these can be used in cases of partial body exposure. Candidate proteins were identified in an earlier study with mice, where skin of the animals was exposed to different doses of radiation and global expression of serum proteins was analyzed. Eight proteins were found,…
Radioluminescence Response of Ce-, Cu-, and Gd-Doped Silica Glasses for Dosimetry of Pulsed Electron Beams
2021
Radiation-induced emission of doped sol-gel silica glass samples was investigated under a pulsed 20-MeV electron beam. The studied samples were drawn rods doped with cerium, copper, or gadolinium ions, which were connected to multimode pure-silica core fibers to transport the induced luminescence from the irradiation area to a signal readout system. The luminescence pulses in the samples induced by the electron bunches were studied as a function of deposited dose per electron bunch. All the investigated samples were found to have a linear response in terms of luminescence as a function of electron bunch sizes between 10−5 Gy/bunch and 1.5×10−2 Gy/bunch. The presented results show that these…
Properties of Gd-Doped Sol-Gel Silica Glass Radioluminescence under Electron Beams
2022
International audience; The radiation-induced emission (RIE) of Gd3+-doped sol–gel silica glass has been shown to have suitable properties for use in the dosimetry of beams of ionizing radiation in applications such as radiotherapy. Linear electron accelerators are commonly used as clinical radiotherapy beams, and in this paper, the RIE properties were investigated under electron irradiation. A monochromator setup was used to investigate the light properties in selected narrow wavelength regions, and a spectrometer setup was used to measure the optical emission spectra in various test configurations. The RIE output as a function of depth in acrylic was measured and compared with a reference…
A study of Type B uncertainties associated with the photoelectric effect in low-energy Monte Carlo simulations
2021
The goal of this manuscript is to estimate Type B uncertainties in absorbed-dose calculations arising from the different implementations in current state-of-the-art Monte Carlo codes of low-energy photon cross-sections (<200 keV). Monte Carlo simulations are carried out using three codes widely used in the low-energy domain: PENELOPE-2018, EGSnrc, and MCNP. Mass energy-absorption coefficients for water, air, graphite, and their respective ratios; absorbed dose; and photon-fluence spectra are considered. Benchmark simulations using similar cross-sections have been performed. The differences observed between these quantities when different cross-sections are considered are taken to be a go…
Low levels of both xanthine dehydrogenase and of cellular retinol binding protein are responsible for retinoic acid deficiency in malignant human mam…
2009
The seeming impairment of retinoid metabolism in human breast tumor cells has been attributed to the lower expression of cellular retinol binding proteins (CRBPs), of alcohol/retinol dehydrogenases, or aldehyde/retinaldehyde dehydrogenases. In a previous study we indicated that xanthine dehydrogenase (XDH) is able to oxidize actively both all-trans-retinol (t-ROL) bound to the CRBP (holo-CRBP) and all-trans-retinaldehyde (t-RAL) to all-trans-retinoic acid (t-RA) in human mammary epithelial cells (HMEC). Since both XDH and CRBP are required for the biosynthesis of t-RA, we have inspected their bioavailability in both estrogen-responsive and nonresponsive human mammary epithelial cancer cells…
The potential of γ-ray spectroscopy for soil proximal survey in clayey soils Le potentiel de la spectroscopie a rayons-γ lors de l’echantillonnage pe…
2013
La spettroscopia di raggi-γ misura la distribuzione e l’intensità della radiazione gamma emessa naturalmente dai suoli o dalle rocce. I radionuclidi più importanti nel suolo come fonte di raggi gamma sono: 40K, 232Th, 238U ed 137Cs, quest’ultimo di origine artificiale, principalmente legato all’esplosione di Chernobyl o ad inquinamenti radioattivi. La distribuzione e la quantità di questi radionuclidi è strettamente dipendente dalla mineralogia del parent material e dalla capacità di scambio cationico del suolo. Scopo di questo lavoro è quello di mostrare le potenzialità di un rilevamento prossimale con spettroscopia di raggi-γ in campi sperimentali con suoli argillosi della Sicilia occiden…
Remote Sensing of 3-D Geometry and Surface Moisture of a Peat Production Area Using Hyperspectral Frame Cameras in Visible to Short-Wave Infrared Spe…
2016
Miniaturized hyperspectral imaging sensors are becoming available to small unmanned airborne vehicle (UAV) platforms. Imaging concepts based on frame format offer an attractive alternative to conventional hyperspectral pushbroom scanners because they enable enhanced processing and interpretation potential by allowing for acquisition of the 3-D geometry of the object and multiple object views together with the hyperspectral reflectance signatures. The objective of this investigation was to study the performance of novel visible and near-infrared (VNIR) and short-wave infrared (SWIR) hyperspectral frame cameras based on a tunable Fabry–Pérot interferometer (FPI) in measuring a 3-D digital sur…