In situ angular measurements of thermal infrared sea surface emissivity—Validation of models
2005
Abstract In this paper, sea surface emissivity (SSE) measurements obtained from thermal infrared radiance data are presented. These measurements were carried out from a fixed oilrig under open sea conditions in the Mediterranean Sea during the WInd and Salinity Experiment 2000 (WISE 2000). The SSE retrieval methodology uses quasi-simultaneous measurements of the radiance coming from the sea surface and the downwelling sky radiance, in addition to the sea surface temperature (SST). The radiometric data were acquired by a CIMEL ELECTRONIQUE CE 312 radiometer, with four channels placed in the 8–14 μm region. The sea temperature was measured with high-precision thermal probes located on oceanog…
Land Surface Temperature From the Advanced Along-Track Scanning Radiometer: Validation Over Inland Waters and Vegetated Surfaces
2009
The land surface temperature (LST) product of the Advanced Along-Track Scanning Radiometer (AATSR) was validated with ground measurements at the following two thermally homogeneous sites: Lake Tahoe, CA/NV, USA, and a large rice field close to Valencia, Spain. The AATSR LST product is based on the split-window technique using the 11- and 12- mum channels. The algorithm coefficients are provided for 13 different land-cover classes plus one lake class (index i). Coefficients are weighted by the vegetation-cover fraction (f). In the operational implementation of the algorithm, i and f are assigned from a global classification and monthly fractional vegetation-cover maps with spatial resolution…
Correction factors for ionization chamber measurements with the ‘Valencia’ and ‘large field Valencia’ brachytherapy applicators
2018
Treatment of small skin lesions using HDR brachytherapy applicators is a widely used technique. The shielded applicators currently available in clinical practice are based on a tungsten-alloy cup that collimates the source-emitted radiation into a small region, hence protecting nearby tissues. The goal of this manuscript is to evaluate the correction factors required for dose measurements with a plane-parallel ionization chamber typically used in clinical brachytherapy for the 'Valencia' and 'large field Valencia' shielded applicators. Monte Carlo simulations have been performed using the PENELOPE-2014 system to determine the absorbed dose deposited in a water phantom and in the chamber act…
Alternate Inrae-Bordeaux VOD Indices from SMOS, AMSR2 and ASCAT: Overview of Recent Developments
2021
International audience; Vegetation optical depth (VOD) is used to parameterize microwave extinction effects within the vegetation layer. Many studies have showed VOD presents interesting features for applications in ecology, water and carbon cycles, and VOD is only marginally impacted by signal disturbances and artefacts from atmospheric, cloud and sun illumination effects. As soil moisture (and not VOD) has generally been the main factor of interest in retrieval studies from microwave observations, there is room for improvement in the retrieved VOD products. In this context, INRAE Bordeaux recently developed alternate VOD products from the SMOS, AMSR2 and ASCAT sensors, by addressing speci…
Spectral calibration and atmospheric correction of ultra-fine spectral and spatial resolution remote sensing data. Application to CASI-1500 data
2007
Imaging spectrometers operating in the solar spectrum measure the upwelling reflected solar radiation, and are an important tool in the bio/geochemical characterization of the Earth system. Surface reflectance is usually the starting point for the retrieval of biophysical parameters from remote measurements. Reliable radiometric and spectral calibrations and accurate atmospheric correction are mandatory in the interpretation of the surface reflectance. A complete surface reflectance retrieval scheme specifically designed for ultra-fine spectral resolution (bandwidth from 10 to 2 nm) and spatial resolution (pixel size less than 10 m) imaging spectrometers is presented in this work. The asses…
On the use of the absorbed depth-dose measurements in the beam calibration of a surface electronic high-dose-rate brachytherapy unit, a Monte Carlo-b…
2019
PURPOSE To evaluate the use of the absorbed depth-dose as a surrogate of the half-value layer in the calibration of a high-dose-rate electronic brachytherapy (eBT) equipment. The effect of the manufacturing tolerances and the absorbed depth-dose measurement uncertainties in the calibration process are also addressed. METHODS The eBT system Esteya® (Elekta Brachytherapy, Veenendaal, The Netherlands) has been chosen as a proof-of-concept to illustrate the feasibility of the proposed method, using its 10 mm diameter applicator. Two calibration protocols recommended by the AAPM (TG-61) and the IAEA (TRS-398) for low-energy photon beams were evaluated. The required Monte Carlo (MC) simulations w…
Direct assessment of the sensitivity drift of SQM sensors installed outdoors
2021
Long-term monitoring of the evolution of the artificial night sky brightness is a key tool for developing science-informed public policies and assessing the efficacy of light pollution mitigation measures. Detecting the underlying artificial brightness trend is a challenging task, since the typical night sky brightness signal shows a large variability with characteristic time scales ranging from seconds to years. In order to effectively isolate the weak signature of the effect of interest, determining the potential long term drifts of the radiance sensing systems is crucial. If these drifts can be adequately characterized, the raw measurements could be easily corrected for them and transfor…
Mobility determination of lead isotopes in glass for retrospective radon measurements
2008
In retrospective radon measurements, the 22-y half life of (210)Pb is used as an advantage. (210)Pb is often considered to be relatively immobile in glass after alpha recoil implanted by (222)Rn progenies. The diffusion of (210)Pb could, however, lead to uncertain wrong retrospective radon exposure estimations if (210)Pb is mobile and can escape from glass, or lost as a result of cleaning-induced surface modification. This diffusion was studied by a radiotracer technique, where (209)Pb was used as a tracer in a glass matrix for which the elemental composition is known. Using the ion guide isotope separator on-line technique, the (209)Pb atoms were implanted into the glass with an energy of …
Experimental measurements for studying angular and spectral variation of thermal infrared emissivity
2004
One condition for precise multiangle algorithms for estimating sea and land surface temperature with the data from the Advanced Along Track Scanning Radiometer is accurate knowledge of the angular variation of surface emissivity in the thermal IR spectrum region. Today there are very few measurements of this variation. The present study is conducted to provide angular emissivity measurements for five representative samples (water, clay, sand, loam, gravel). The measurements are made in one thermal IR broadband (8-13 microm) and three narrower bands (8.2-9.2, 10.3-11.3, and 11.5-12.5 microm) at angles of 0 degrees-60 degrees (at 5 degrees increments) to the surface normal. The results show a…
Actinic Radiation and Photolysis Processes in the Lower Troposphere: Effect of Clouds and Aerosols
2002
Within the German Tropospheric Research Program (TFS) a series of projects were performed focussing on aspects of radiation transfer and the effects of UV-radiation on air chemistry. The individual projects covered laboratory investigations, instrument development for photolysis processes as well as field studies of actinic radiation and comparison to model calculations. One and three-dimensional models were tested against field campaign data. The results confirm the improvement of measurement technology achieved through deployment of new techniques like spectroradiometry that offer a wider range of investigations than was previously attainable using chemical actinometry or fixed wavelength…