Search results for "Radiometry"
showing 10 items of 170 documents
The flex end-to-end simulator: From concept phase (A/B1) to ground segment and operations (C/D)
2018
ESA's FLEX/Sentinel-3 tandem mission aims at mapping Sun-induced fluorescence (SIF) as a proxy to quantify photosynthetic activity of terrestrial vegetation. Due to the complexity of the mission concept and stringent requirements for the data processing algorithms, ESA developed a Phase A/B1 End-to-End Mission Performance Simulator (E2ES) tool to reproduce the expected mission performance and check the mission and instrument concepts. In the current Phase C/D, the E2ES concept must evolve to consolidate the whole data processing chain, providing an accurate figures of the whole mission error budget and serving as a roadmap for the future development of FLEX Ground Segment. This paper gives …
Comparison between SMOS Vegetation Optical Depth products and MODIS vegetation indices over crop zones of the USA
2014
The Soil Moisture and Ocean Salinity (SMOS) mission provides multi-angular, dual-polarised brightness temperatures at 1.4 GHz, from which global soil moisture and vegetation optical depth (tau) products are retrieved. This paper presents a study of SMOS' tau product in 2010 and 2011 for crop zones of the USA. Retrieved tau values for 504 crop nodes were compared to optical/IR vegetation indices from the MODES (Moderate Resolution Imaging Spectroradiometer) satellite sensor, including the Normalised Difference Vegetation Index (NDVI), Enhanced Vegetation Index (EVE), Leaf Area Index (LAI), and a Normalised Difference Water Index (NOW!) product. tau values were observed to increase during the…
A radiometric and petrographic approach to risk assessment at Alte Madonie Mounts region (Sicily, Italy)
2013
The main goal of this work was to assess the radiological hazard at Alte Madonie Mounts region (north-central Sicily, Italy) in response to rumours of an increase in the incidence of cancer in this area. A correlation between the natural radionuclide contents and the petrographic features of the soil and rock samples was also evaluated. A total of 41 samples of selected soils and rocks were collected, powdered, dried and sealed in 'Marinelli' beakers for 20 d prior to measurement to ensure that a radioactive equilibrium between (226)Ra and (214)Bi had been reached. A gamma-ray spectrometer was used to quantify the radioactivity concentrations. To determine (238)U and (232)Th activities, the…
Biodosimetry Based on γ-H2AX Quantification and Cytogenetics after Partial- and Total-Body Irradiation during Fractionated Radiotherapy
2015
The aim of this current study was to quantitatively describe radiation-induced DNA damage and its distribution in leukocytes of cancer patients after fractionated partial- or total-body radiotherapy. Specifically, the impact of exposed anatomic region and administered dose was investigated in breast and prostate cancer patients receiving partial-body radiotherapy. DNA double-strand breaks (DSBs) were quantified by γ-H2AX immunostaining. The frequency of unstable chromosomal aberrations in stimulated lymphocytes was also determined and compared with the frequency of DNA DSBs in the same samples. The frequency of radiation-induced DNA damage was converted into dose, using ex vivo generated ca…
Fetal dose measurements and shielding efficiency assessment in a custom setup of (192)Ir brachytherapy for a pregnant woman with breast cancer.
2015
To assess the radiation dose to the fetus of a pregnant patient undergoing high-dose-rate (HDR) (192)Ir interstitial breast brachytherapy, and to design a new patient setup and lead shielding technique that minimizes the fetal dose.Radiochromic films were placed between the slices of an anthropomorphic phantom modeling the patient. The pregnant woman was seated in a chair with the breast over a table and inside a leaded box. Dose variation as a function of distance from the implant volume as well as dose homogeneity within a representative slice of the fetal position was evaluated without and with shielding.With shielding, the peripheral dose after a complete treatment ranged from 50 cGy at…
A Single-Channel Algorithm for Land-Surface Temperature Retrieval From ASTER Data
2010
This letter presents an adaptation to Advanced Spaceborne Thermal Emission and Reflection Radiometer (ASTER) data of the generalized single-channel (SC) algorithm developed by JimE?nez-MuN?oz and Sobrino, also adapted to the Landsat thermal-infrared (TIR) channel (band 6) later by JimE?nez-MuN?oz The SC algorithm relies on the concept of atmospheric functions (AFs), which are dependent on atmospheric transmissivity, upwelling, and downwelling atmospheric radiances. These AFs are fitted versus the atmospheric water-vapor content for operational purposes, despite the fact that other computation options are also possible. The SC algorithm has been adapted to ASTER TIR bands 13 (10.659 ?m) and …
Atmospheric water vapor content over land surfaces derived from the AVHRR data: application to the Iberian Peninsula
1999
A study has been carried out using simulated NOAA/advanced very high resolution radiometer (AVHRR) data at 11 and 12 /spl mu/m (with LOWTRAN-7, MODTRAN 2.0, and the TIGR database), AVHRR images of the Iberian Peninsula and the Palma de Mallorca Island, radiosonde observations at seven meteorological stations, and the AVISO database provided by Meteo France to describe, compare, and analyze two different approaches for estimating the total atmospheric water vapor content (W) over land surfaces from AVHRR data. These two techniques are: 1) the split-window covariance-variance ratio (SWCVR), based on a quadratic relationship between W and the ratio of the spatial covariance and variance of bri…
Emissivity measurements of several soils and vegetation types in the 8–14, μm Wave band: Analysis of two field methods
1997
Abstract The two variants of the box method (with one and two lids) has been rigorously analyzed. As a result of this analysis, a correction factor that takes into account the nonideality of the materials used for the box, as well as its geometry, has been derived A simple method for determining the effective downward atmospheric temperature that uses only the temperature measurement at the zenith also has been proposed. Finally, by using one of the two variants of the box method, 72 in situ emissivity measurements in the 8–14 pin wave-band region of typical vegetation, soils, and rocks of Europe and South America, has been obtained. The use of these data for the ernissivity correction of s…
ESR response to gamma-rays of alanine pellets containing B(OH)3 or Gd2O3.
2007
ESR response to gamma-irradiation (1-50 Gy) of blends containing alanine and either B(OH)(3) or Gd(2)O(3) is reported. The sensitivity of the alanine--B(OH)(3) blend is comparable to the sensitivity of pure alanine, although its lowest detectable dose, LDD, is smaller ( approximately 1.3 Gy) than that of pure alanine ( approximately 2.9 Gy). Alanine with Gd(2)O(3) is about two times more sensitive than pure alanine, and its LDD is 0.8 Gy. The better sensitivity and LDD are probably due to the high atomic number (Z=64) of gadolinium, which enhances the interaction probability with photons and, consequently, the radical yield. This study suggests that other high-Z atoms may be useful for incr…
A tailor-made nucleoside-based colourimetric probe of formic acid
2014
A ratiometric, specific probe of formic acid has been developed. It is based on intermolecular nucleobase-pairing of inosine-capped plasmonic nanoparticles to form nucleoside channels, which are destabilised by the analyte.