Performance of a FieldSpec spectroradiometer for aerosol optical depth retrieval: method and preliminary results
2009
The performance of a FieldSpec spectroradiometer for retrieving aerosol optical depth (AOD) has been assessed after modifying its basic configuration in order to measure direct solar irradiance at ground level. The FieldSpec measurements were obtained during four summertime days in the years 2004 and 2005, over a Spanish agricultural site in Barrax, Albacete (30 degrees 3(') N, 2 degrees 6(') W, 700 m a.s.l.), in the framework of two European Space Agency mission remote sensing field campaigns. From the whole FieldSpec spectral domain (350-2500 nm) the AOD was extracted for channels within atmospheric windows. The instrument was calibrated by means of the standard Langley plot method, perfo…
About the Problem of Scaling from Ground Measurements to Low Resolution Satellite Data
2005
Only satellite data can really produce "global" datasets, and the role of satellite data in the study of global processes is really essential, but ground measurements are also needed to calibrate satellite data and to validate models routinely working with satellite data inputs. The problem of comparing ground measurements with the measurements made by a satellite, particularly in the case of low resolution data (as NOAA AVHRR) imply the consideration of the problem of scaling, both in the case of particular measurements and in the case of mathematical models relating such measurements. Within the context of the EFEDA field experiment, the problem of scaling from ground measurements to low …
Comparison of two portable solid state detectors with an improved collimation and alignment device for mammographic x-ray spectroscopy.
2006
We describe a portable system for mammographic x-ray spectroscopy, based on a 2 X 2 X 1 mm3 cadmium telluride (CdTe) solid state detector, that is greatly improved over a similar system based on a 3 X 3 X 2 mm3 cadmium zinc telluride (CZT) solid state detector evaluated in an earlier work. The CdTe system utilized new pinhole collimators and an alignment device that facilitated measurement of mammographic x-ray spectra. Mammographic x-ray spectra acquired by each system were comparable. Half value layer measurements obtained using an ion chamber agreed closely with those derived from the x-ray spectra measured by either detector. The faster electronics and other features of the CdTe detecto…
Characterization of phenolic pellets for ESR dosimetry in photon beam radiotherapy
2017
This work deals with the dosimetric features of a particular phenolic compound (IRGANOX 1076 ® ) for dosimetry of clinical photon beams by using electron spin resonance (ESR) spectroscopy. After the optimization of the ESR readout parameters (namely modulation amplitude and microwave power) to maximise the signal without excessive spectrum distortions, basic dosimetric properties of laboratory-made phenolic dosimeters in pellet form, such as reproducibility, dose–response, sensitivity, linearity and dose rate dependence were investigated. The dosimeters were tested by measuring the depth dose profile of a 6 MV photon beam. A satisfactory intra-batch reproducibility of the ESR signal of the …
Air-kerma evaluation at the maze entrance of HDR brachytherapy facilities.
2014
In the absence of procedures for evaluating the design of brachytherapy (BT) facilities for radiation protection purposes, the methodology used for external beam radiotherapy facilities is often adapted. The purpose of this study is to adapt the NCRP 151 methodology for estimating the air-kerma rate at the door in BT facilities. Such methodology was checked against Monte Carlo (MC) techniques using the code Geant4. Five different facility designs were studied for (192)Ir and (60)Co HDR applications to account for several different bunker layouts.For the estimation of the lead thickness needed at the door, the use of transmission data for the real spectra at the door instead of the ones emit…
Dose determination using alanine detectors in a mixed neutron and gamma field for boron neutron capture therapy of liver malignancies
2011
IntroductionBoron Neutron Capture Therapy for liver malignancies is being investigated at the University of Mainz. One important aim is the set-up of a reliable dosimetry system. Alanine dosimeters have previously been applied for dosimetry of mixed radiation fields in antiproton therapy, and may be suitable for measurements in mixed neutron and gamma fields.Materials and MethodsTwo experiments have been carried out in the thermal column of the TRIGA Mark II reactor at the University of Mainz. Alanine dosimeters have been irradiated in a phantom and in liver tissue.ResultsFor the interpretation and prediction of the dose for each pellet, beside the results of the measurements, calculations …
Improvement of ESR dosimetry for thermal neutron beams through the addition of gadolinium.
2007
In this paper, the addition of gadolinium is proposed as a useful tool to enhance the electron spin resonance (ESR) sensitivity of organic compounds to thermal neutrons. The target of this work is the detection, through the ESR technique, of the thermal neutron fluence in a mixed field of photons and neutrons. Gadolinium was chosen because it has a very high capture cross section to thermal neutrons; its nuclear reaction with thermal neutrons induces complex inner shell transitions that generate, besides other particles, Auger electrons, which in turn release their energy in the neighborhood (only several nanometers) of the place of reaction. Gadolinium was added to two organic molecules: a…
Clinical Translation and First In-Human Use of [44Sc]Sc-PSMA-617 for PET Imaging of Metastasized Castrate-Resistant Prostate Cancer
2017
Background: Various trivalent radiometals are well suited for labeling of DOTA-conjugated variants of Glu-ureido-based prostate-specific membrane antigen (PSMA) inhibitors. The DOTA-conjugate PSMA-617 has proven high potential in PSMA radioligand therapy (PSMA-RLT) of prostate cancer as well as PET imaging when labeled with lutetium-177 and gallium-68 respectively. Considering the relatively short physical half-life of gallium-68 this positron emitter precludes prolonged acquisition periods, as required for pre-therapeutic dosimetry or intraoperative applications. In this context, the positron emitter scandium-44 is an attractive alternative for PET imaging. We report the synthesis of [44Sc…
Rapid quantitative method for measuring phagocytosis of Leishmania promastigotes using a double radiolabelling method.
1990
A double radiolabelling method is described for the measurement of phagocytosis of Leishmania major promastigotes in cultures of murine resident peritoneal macrophages. L. major promastigotes were radiolabelled during exponential growth in RPMI supplemented with [125I]5-iodo-2-deoxyuridine. They were used to infect sodium [51Cr]chromate-labelled macrophages. Phagocytosis was evaluated by measuring the radioactivity of the 125IUdR-labelled parasites detectable inside 51Cr-labelled macrophages by a Beckmann gamma 5500 counting system. This was able to count simultaneously, in two different windows the radioactivity of (a) the parasites and (b) the cells. The technique compares favorably with …
Mobile phone use and exposures in children.
2005
The main difference concerning the use of mobile phones (MPs) between today's children and adults is the longer lifetime exposure of children when they grow older, due to starting to use MPs at an early age. Additionally, recent trends lead to a higher frequency of use among children, including higher popularity of MPs and features specifically designed to attract children. The prevalence of MP users is already very high and reaches >90% among adolescents in some countries. In a German study, 6% of 9-10 years old children used a MP for making calls daily; 35% owned their own MP. For children, MPs are dominant sources of radio wave exposures and relevant sources of extremely low frequency ma…