Search results for "Radius"

showing 10 items of 708 documents

Finger ridge-count asymmetry and diversity in Andean Indians and interpopulation comparisons

1998

A separate analysis of ulnar and radial finger ridge-counts, obtained from 115 Aymara Indians (55 males and 60 females) of northern Chile, was performed. From these variables, directional asymmetry, fluctuating asymmetry, indices of bilateral asymmetry (square root of A2), and intraindividual diversity (s/square root of 5) were calculated for each sex. The results show that most bimanual differences for the ridge-counts are not statistically significant in the Aymara, except for radial counts in female first and second fingers (right hand means are larger), while most ulnar-radial differences are highly significant in both sexes (radial values exceed ulnar ones). Most sex differences do not…

AdultMaleAdolescentmedia_common.quotation_subjectUlnaBiologyAsymmetryFluctuating asymmetryFingersSex FactorsStatistical significanceEthnicityHumansChileChildSouthern Hemispheremedia_commonBilateral asymmetryIndians South AmericanRidge countRadiusAnthropologyFemaleAnatomyDermatoglyphicsDiversity (business)DemographyAmerican Journal of Physical Anthropology
researchProduct

The anatomy of the proximal radius: implications on fracture implant design.

2012

Background The proximal radius features a complex anatomy. Several studies have been published on the anatomy using different technical approaches; however, most of these studies were conducted with a special focus on parameters relevant to radial prosthetic design. The purpose of our study was to explore the complex geometry of the proximal radius with regard to fracture implant design. Methods Our computed tomography-based measurements of 78 multiplanar reformatted radii allow for exact assessment of its geometry and offer a scientific rationale towards the design of fracture implants. We conducted measurements on the radial head, the radial neck, the radial tuberosity, the radial head-to…

AdultMaleElbow ProsthesisProsthesis DesignFractures BoneYoung AdultmedicineHumansOrthopedics and Sports MedicineAgedAged 80 and overRadial neckNormal anatomybusiness.industryImplant designRadial headGeneral MedicineRadial tuberosityAnatomyRadiusMiddle AgedRadiusmedicine.anatomical_structureProximal radiusFracture (geology)SurgeryFemalebusinessElbow InjuriesJournal of shoulder and elbow surgery
researchProduct

Light distortion of soft multifocal contact lenses with different pupil size and shape

2020

Purpose: To study the light distortion effects of soft multifocal contact lenses and the influence of different pupil size and shape.Methods: A total of 14 eyes of 7 healthy contact lens users (mean age 28.6 +/- 8.5 years) were recruited. The "Light Disturbance Analyser" device was employed for light characterization. The selected lenses were the monthly disposable "Biofinity multifocal" (CooperVision, CA, USA), both centre-distance and centre-near designs (addition power + 2.50 D). Two circular pupils of 3 mm and 5 mm of diameter, and an elliptical shape (3 horizontal and 5 vertical mm) were used. Metrics such as the light distortion index (LDI), best-fit circle radius and its irregularity…

AdultMaleLight distortionbusiness.product_categorygenetic structuresCiências Naturais::Ciências Físicas:Ciências Físicas [Ciências Naturais]Visual AcuityRefraction OcularPupillaw.invention03 medical and health sciences0302 clinical medicineOpticslawDistortionNon-circular pupilsHumansMultifocal lensesMathematicsScience & Technologybusiness.industryPupil sizePupilMean ageEquipment DesignGeneral MedicineRadiusMiddle AgedContact Lenses HydrophilicRefractive ErrorsHealthy Volunteerseye diseasesContact lensLens (optics)Ophthalmology030221 ophthalmology & optometryMultifocal contact lensesFemalesense organsbusiness030217 neurology & neurosurgeryOptometryContact Lens and Anterior Eye
researchProduct

New syndrome: Autosomal dominant microcephaly and radio-ulnar synostosis

1994

To date, the combination of microcephaly and radio-ulnar synostosis has not been recognized as a distinct clinical and genetic entity. We report on 4 familial cases with this previously undescribed combination of defects, showing autosomal dominant inheritance (Fig. 1). © 1994 Wiley-Liss, Inc.

AdultMaleMicrocephalyAdolescentUlnaSupinationMedicineHumansAbnormalities MultiplemicrocephalyChildGenetics (clinical)Genes Dominantradioulnar synostosisbusiness.industryfungiInfantAnatomySyndromeSynostosisMiddle Agedmedicine.diseasePedigreeautosomal dominant inheritanceRadiusSynostosisRadioulnar synostosisFemaleCongenital diseasebusinessHand Deformities Congenital
researchProduct

Autosomal dominant and sporadic radio-ulnar synostosis.

1997

We report on seven cases of congenital radio-ulnar synostosis (RUS). Five were found in the same family and two were sporadic. In six the synostosis was bilateral and consistently involved the proximal end of the radius and ulna. In the familial cases the anomaly was inherited as an autosomal dominant trait and was associated with a Dubois sign and relative shortness of metacarpals number 4 and 5 in two patients, and of number 2 in another patient, and of all phalanges of the 5th fingers. These observations suggest involvement of an ulnar developmental field. RUS does not seem to be rare in the Sicilian population.

AdultMalePopulationUlnaFingersElbow JointmedicineHumanseducationSicilyGenetics (clinical)Agededucation.field_of_studybusiness.industryUlnaInfant NewbornAutosomal dominant traitInfantAnatomySyndromeSynostosisPhalanxmedicine.diseasePedigreeRadiographyRadiusmedicine.anatomical_structureSynostosisFemalebusinessAmerican journal of medical genetics
researchProduct

Complex radial head and neck fractures treated with modern locking plate fixation

2019

Background Internal fixation of complex radial head and neck (CRHN) fractures is difficult, and postoperative complications are common. This study evaluated elbow function and patient clinical status after internal fixation of CRHN fractures with modern locking plates. Methods We included 40 patients with 41 fractures (1 bilateral lesion). In 25 patients (61%), a concomitant injury was found. Patients were an average age of 46 years (range, 22-70 years). The mean follow-up time was 36 months (range, 2-70 months). Postoperative assessments included evaluation of range of motion, functional scores, and radiologic findings. We assessed fracture healing, surgical complications, revision surgery…

AdultMaleReoperationmedicine.medical_specialtyJoint replacementmedicine.medical_treatmentElbowBone healingSupinationFracture Fixation InternalYoung Adult03 medical and health sciencesFixation (surgical)0302 clinical medicineElbow JointHumansMedicineInternal fixationPronationOrthopedics and Sports MedicineRange of Motion ArticularDevice RemovalAgedFracture Healing030222 orthopedicsbusiness.industry030229 sport sciencesGeneral MedicineMiddle AgedSurgeryTreatment Outcomemedicine.anatomical_structureConcomitantFemaleSurgeryRadial head fractureRadius FracturesbusinessRange of motionBone PlatesEpiphysesFollow-Up StudiesJournal of Shoulder and Elbow Surgery
researchProduct

Modeling the impact of soft tissue on axial transmission measurements of ultrasonic guided waves in human radius

2008

Recent in vitro and simulation studies have shown that guided waves measured at low ultrasound frequencies (f=200 kHz) can characterize both material properties and geometry of the cortical bone wall. In particular, a method for an accurate cortical thickness estimation from ultrasound velocity data has been presented. The clinical application remains, however, a challenge as the impact of a layer of soft tissue on top of the bone is not yet well established, and this layer is expected to affect the dispersion and relative intensities of guided modes. The present study is focused on the theoretical modeling of the impact of an overlying soft tissue. A semianalytical method and finite-differ…

AdultMaleTime FactorsMaterials scienceAcoustics and UltrasonicsAcousticsModels BiologicalMotionYoung AdultOpticsArts and Humanities (miscellaneous)Image Interpretation Computer-AssistedmedicineHumansComputer SimulationTime domainDispersion (water waves)AgedUltrasonographyAged 80 and overGuided wave testingbusiness.industryUltrasoundBiomechanicsReproducibility of ResultsNumerical Analysis Computer-AssistedRadiusMiddle AgedRadiusmedicine.anatomical_structureConnective TissueFemaleUltrasonic sensorCortical bonebusinessThe Journal of the Acoustical Society of America
researchProduct

Intraoperative C-arm CT imaging in angular stable plate osteosynthesis of distal radius fractures

2013

The purpose of this study was to analyze the practicability and benefit of intraoperative C-arm computed tomography (CT) imaging in volar plate osteosynthesis of unstable distal radius fractures. During a 1 year period, intraoperative three dimensional (3D) imaging with the ARCADIS Orbic 3D was performed in addition to standard fluoroscopy in 51 cases. The volar angular stable plate oesteosyntheses were analyzed intraoperatively and, if necessary, improved immediately. The duration of the scan and radiation exposure dose were measured. On average, performance of the scan and analysis of the CT dataset took 6.7 minutes. In 31.3% of the surgeries a misplacement of screws was detected and cor…

AdultMalemedicine.medical_specialtyBone ScrewsComputed tomographyRadiation DosageFracture Fixation InternalIntraoperative PeriodImaging Three-DimensionalmedicineHumansFluoroscopyProspective StudiesAgedDigital radiographyAged 80 and overOsteosynthesismedicine.diagnostic_testbusiness.industryRadiusMiddle AgedRadiation exposureTreatment OutcomePlate osteosynthesisFluoroscopyFemaleSurgeryRadiologyCt imagingRadius FracturesTomography X-Ray ComputedbusinessBone PlatesJournal of Hand Surgery (European Volume)
researchProduct

The treatment of wrist fractures with Epibloc System

2011

BACKGROUND Fractures of the distal extremity of the radius are the most common bone lesions of the superior extremity of the body, representing 17% of the fractures treated in First Aid facilities. The restoration of anatomical relationships in the radiocarpal joint is considered to be a prerequisite for good functional recovery. There are numerous methods of treatment of these fractures. The Epibloc system is a percutaneous endomedullary synthesis alternative to the plaster cast in wrist fracture treatment. MATERIALS AND METHODS The authors describe their experience with 81 fractures (63 type A2-3 fractures and 18 type C1) of the wrist treated with the Epibloc System (ES). The results were…

AdultMalemedicine.medical_specialtyPercutaneousmedicine.medical_treatmentWristBone NailsFracture Fixation InternalFractures BoneMedicineHumansOrthopedics and Sports MedicineOsteodystrophyMalunionReduction (orthopedic surgery)Agedbusiness.industryRehabilitationMiddle Agedmedicine.diseaseFunctional recoveryWrist InjuriesSurgeryPercutaneous pinningmedicine.anatomical_structureTreatment Outcomedistal radius fracture wrist fracture Epibloc system percutaneous synthesis percutaneous pinningFemaleWRIST FRACTUREbusiness
researchProduct

Reliability of upper-limb diaphyseal mineral and soft-tissue measurements using peripheral quantitative computed tomography (pQCT)

2018

Objectives: To quantify between-day reliability of upper-body diaphyseal measurements (radius, ulna, humerus) using peripheral Quantitative Computed Tomography (pQCT). - Methods: Fourteen males (age: 25.8±2.3 years,) underwent repeat pQCT scans (one to two days apart) at mid-shaft ulna (60%), mid-shaft radius (60%) and mid-shaft humerus (50%) cross-sections of the non-dominant limb. Intraclass correlation coefficients (ICC) and coefficients of variation (CV) were determined for musculoskeletal morphology variables. - Results: Reliability was excellent (ICC: 0.76–0.99; CV: 1.3– 7.3) at all sites for bone mass, stress-strain index, endocortical and pericortical radius, endocortical volumetric…

AdultMalereliabilityluuluuntiheysUlnaHumerusReliabilityCohort StudiesUpper ExtremityRadiusYoung AdulthumerustomografiaHumanstietokonetomografiaOriginal ArticleulnaTomography X-Ray ComputedBoneradiusreliabiliteetti
researchProduct