Search results for "Rao"
showing 10 items of 1049 documents
Laparoscopic treatment for esophageal achalasia: experience at a single center
2013
Background. Achalasia is a not frequent esophageal disorder cha- racterized by the absence of esophageal peristalsis and incomplete re- laxation of the lower esophageal sphincter (LES). Its cause is unknown. The aim of treatment is to improve the symptoms. We report the results of the treatment of this condition achieved in one center. Patients and methods. We conducted a retrospective study of pa- tients with esophageal achalasia. In the period 2010-2012 we observed 64 patients, of whom 19 were referred for medical treatment. Three of Introduction Achalasia is a not frequent esophageal motor disor- der that affects both the body of the esophagus and the lower esophageal sphincter (LES). It…
Curvature of iris profile in spectral domain optical coherence tomography and dependency to refraction, age and pupil size - the MIPH Eye&Health …
2016
Purpose Optical coherence tomography (OCT) of the anterior segment allows quantitative analysis of the geometry of the iris. We performed spectral domain OCT examinations in healthy emmetropic, hyperopic and myopic subjects to investigate iris curvature and its associations. Methods In a cross-sectional study, out of 4617 eyes (2309 subjects) those with refractive errors of +3 dioptres were identified by objective refraction. The iris was examined using the anterior segment mode of a spectral domain 3D OCT-2000 (Topcon Inc., Japan) in the temporal meridian, and OCT scans were investigated with respect to presence and amount of convex and concave iris configuration. Ninety-three eyes of 50 s…
Contrast sensitivity and glare disability by halogen light after monofocal and multifocal lens implantation
2000
BACKGROUND—Standard examination of contrast sensitivity under conditions of glare disability is performed with incandescent light. A new halogen glare test that simulates glare as seen with oncoming vehicle headlights was used to measure glare disability in patients implanted with multifocal and monofocal intraocular lenses (IOLs). METHODS—28 patients with an average age of 69 years (SD 12 years) were implanted with a monofocal IOL (SI-40NB, Allergan) and 28 patients with an average of 66 years (12 years) were implanted with a refractive multifocal IOL (Array-SA-40N, Allergan). All patients were followed for 5 months postoperatively. Contrast sensitivity at four spatial frequencies (3, 6, 1…
Goldmann Applanation Tonometry Using Sterile Disposable Silicone Tonometer Shields
1996
Abstract Purpose: Placement of a sterile single-use cover over the tonometer tip may be a convenient and safe alternative method to repeated chemical disinfection. This study was undertaken to evaluate the accuracy and performance of Goldmann applanation tonometry using a sterile disposable silicone tonometer shield over the biprism tip. Methods: The same investigator measured intraocular pressure in 120 eyes with and without the shield. The eyes were tested randomly first with either the uncovered or the covered tonometer to control for the possible effects of repeated tonometry influencing measurement differences. Readings were recorded independently in a masked fashion. Results: The intr…
Comparison of Dynamic Contour Tonometry and Goldmann Applanation Tonometry in Glaucoma Patients and Healthy Subjects
2006
To investigate the agreement in the measurement of intraocular pressure (IOP) obtained by dynamic contour tonometry PASCAL (DCT-PASCAL) and Goldmann applanation tonometry (GAT) in glaucoma eyes and healthy eyes with different central corneal thickness (CCT).Prospective cross-sectional study.In a randomized order, three consecutive IOP measurements were performed on 197 eyes of 107 subjects by one examiner using both DCT-PASCAL and GAT on all eyes. Furthermore, ultrasonic pachymetry was performed. The Spearman correlation coefficient (r) was determined to compare IOP readings between DCT-PASCAL and GAT. Regression-based Bland and Altman analysis was used to evaluate agreement between the ins…
The relationship between central corneal thickness and Goldmann applanation tonometry
2003
The aim of this study was to investigate the relationship between Goldmann applanation tonometry and central corneal thickness in a large sample of healthy eyes.Five hundred eyes of 500 subjects (253 women, 50.6 per cent and 247 men, 49.4 per cent) were analysed in a prospective healthy population study. Mean age of the sample was 31 +/- 8 years. Goldmann applanation tonometry was carried out by one physician. Tonometric values were the mean of three consecutive readings. Subsequently, another physician carried out ultrasonic pachymetry with the DGH 2000 AP ultrasonic pachymeter (DGH Technology Inc, San Diego, USA). Ten measurements were made at the centre of the cornea of each eye. The low…
Human cerebral microcirculation and oxygen saturation during propofol-induced reduction of bispectral index †
2011
† This study investigates the effects of propofol-induced changes in bispectral index (BIS) on cerebral microcirculation and oxygenation during craniotomies. † In 2 mm cerebral depth, an increase in propofol dosage resulted in increased oxygen saturation (srvO2 )w ithout reduction of capillary venous blood flow (rvCBF). † Difference in oxygen content (avDO2) and approximated cerebralmetabolicrateofoxygen (aCMRO2) decreased with an increase in propofol dosage in 2 mm cerebral depth. † Alterations in BIS showed no effect on rvCBF, srvO2 ,a nd haemoglobin amount (rvHb) or on avDO2 or aCMRO2 in 8 mm cerebral depth. † These findings suggest that the CBF/CMRO2 ratio is altered by propofol in a re…
Automatic algorithm for monitoring systolic pressure variation and difference in pulse pressure.
2009
BACKGROUND: Difference in pulse pressure (dPP) reliably predicts fluid responsiveness in patients. We have developed a respiratory variation (RV) monitoring device (RV monitor), which continuously records both airway pressure and arterial blood pressure (ABP). We compared the RV monitor measurements with manual dPP measurements. METHODS: ABP and airway pressure (PAW) from 24 patients were recorded. Data were fed to the RV monitor to calculate dPP and systolic pressure variation in two different ways: (a) considering both ABP and PAW (RV algorithm) and (b) ABP only (RV(slim) algorithm). Additionally, ABP and PAW were recorded intraoperatively in 10-min intervals for later calculation of dPP …
Perioperative nonspecific histamine release : a new classification by aetiological mechanisms and evaluation of their clinical relevance
1993
As a consequence of the performance of a randomized controlled clinical trial on perioperative histamine release and cardiovascular and respiratory disturbances, several types of increases in plasma histamine had to be distinguished instead of only two which existed at the beginning of the study: drug-induced allergic and pseudoallergic reactions. First of all, the new classification by aetiology (clinical epidemiology) was derived from a meta-analysis (secondary analysis) of the most recent literature. According to that histamine release in the perioperative period has several, different causes and is involved in several, different disease manifestations. A clear distinction (classificatio…
Characterization of blink reflex interneurons by activation of diffuse noxious inhibitory controls in man.
1998
The blink reflex consists of an early, pontine R1-component and a late, medullary R2-component. R1 and R2 can be evoked by innocuous stimuli, but only the R2 also by painful heat, suggesting that the R2 is mediated by wide dynamic range neurons (WDR) of the spinal trigeminal nucleus. Remote noxious stimuli suppress the activity in WDR neurons via activation of diffuse noxious inhibitory controls (DNIC), whereas low-threshold mechanoreceptive neurons (LTM) are unaffected. In order to characterize the trigeminal interneurons of R1 and R2 we investigated the modulation of the blink reflex by remote painful heat. The blink reflex was elicited in 11 healthy subjects by innocuous electrical pulse…