Search results for "Rating"

showing 10 items of 2021 documents

Nanovised Control Flow Attestation

2022

This paper presents an improvement of control flow attestation (C-FLAT) for Linux. C-FLAT is a control attestation system for embedded devices. It was implemented as a software executing in ARM’s TrustZone on bare-metal devices. We extend the design and implementation of C-FLAT through the use of a type 2 Nanovisor in the Linux operating system. We call our improved system “C-FLAT Linux”. Compared to the original C-FLAT, C-FLAT Linux reduces processing overheads and is able to detect the SlowLoris attack. We describe the architecture of C-FLAT Linux and provide extensive measurements of its performance in benchmarks and real-world scenarios. In addition, we demonstrate the…

Fluid Flow and Transfer ProcessespääsynvalvontaSoftware_OPERATINGSYSTEMSvirtualisointiProcess Chemistry and TechnologyLinuxhypervisor; ARM; Linux; control flow; SlowLoris; TrustZoneSlowLorisGeneral EngineeringTrustZonecontrol flowComputer Science ApplicationsARMGeneral Materials SciencehypervisortietoturvaInstrumentationApplied Sciences; Volume 12; Issue 5; Pages: 2669
researchProduct

Changes to legal forensic inspections in Sicily during Covid-19

2020

Our institute, in collaboration with the Public Prosecutor’s Office, arranges for cadaveric inspections during a judicial inspection, jointly with the police. With the advent of the Covid-19 pandemic, operating methods have changed. Specifically, we now discuss the cases individually before attending to guarantee the health of operators and citizens

Forensic pathology2019-20 coronavirus outbreakCoronavirus disease 2019 (COVID-19)Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2)Pneumonia ViralSpecimen HandlingSettore MED/43 - Medicina LegalePandemicmedicineHumansForensic PathologyPandemicsSicilybusiness.industryCOVID-19General MedicineForensic Medicinemedicine.diseasecadaveric ispection covid 19 operating methodForensic scienceAutopsyClinical CompetenceMedical emergencyClinical competenceCoronavirus InfectionsbusinessCoronavirus InfectionsMedico-Legal Journal
researchProduct

A topology for multiple generation system with doubly fed induction machines and indirect matrix converter.

2008

In this paper, a new topology for a grid connected generation system based on two double fed induction generators is presented The scheme uses an indirect matrix converter consisting on an input rectifier, a three-to-two matrix converter which provides a DC voltage, and two voltage fed output converters. The input converter is connected to the grid and each of the output converters is connected to the rotor of the corresponding machine. The rotor currents of each generator are vector controlled and unity power factor operation at the indirect matrix converter input is considered. The duty cycles for the input converter are chosen in order to obtain maximum DC link voltage. The duty cycles f…

Forward converterEngineeringControl theoryFlyback converterBuck converterbusiness.industryBoost converterBuck–boost converterĆuk converterIntegrating ADCTopologybusinessSINADR2008 IEEE International Symposium on Industrial Electronics
researchProduct

Difference temperature-to-time electronic interface based on a thermistor-to-generalized impedance converter

2010

Abstract In this work a difference temperature-to-time converter is shown using two thermistors working in a DC generalized impedance converter. Voltage drop in one of the thermistors depends on the temperature difference between them. This voltage is compared with a time varying exponential reference voltage obtaining a time interval at the output circuit with good linear dependence with respect to the input temperature difference. Experimental results are obtained showing a new generalized impedance converter application. The implemented circuit was characterized by a repeatability of 1.0%, a reproducibility of 4.5% and a relative accuracy of 1.3%.

Forward converterMaterials scienceApplied MathematicsThermistorCondensed Matter PhysicsIntegrating ADCSINADRControl theoryElectrical and Electronic EngineeringInstrumentationVoltage dropVoltage referenceNegative impedance converterVoltageMeasurement
researchProduct

Dynamic modelling of a quadratic DC/DC single-switch boost converter

2017

This manuscript proposes the analysis of a Quadratic Boost Converter (QBC) transformer-less single switch typology. The state space average dynamic model and a constrained state space average model taking into account the mono-directional components of the converter (diodes, switches) have been analyzed. The static gain expression taking into consideration the parasitic elements of the converter and the small-signal transfer function of the QBC typology under study has been obtained. A sensitivity analysis has shown a high variation of the gain versus duty-cycle and of the derivative gain versus parasitic parameters of the converter in the range of the duty-cycle from 0.6 to 0.8 which is ra…

Forward converterQuadratic Boost ConverterBuck converterFlyback converter020209 energy020208 electrical & electronic engineeringBuck–boost converterĆuk converterEnergy Engineering and Power Technology02 engineering and technologyIntegrating ADCSINADRModellingControl theoryDC/DC converterBoost converter0202 electrical engineering electronic engineering information engineeringElectrical and Electronic EngineeringMathematics
researchProduct

Analysis of Fresnel Zone Plates Focusing Dependence on Operating Frequency

2017

[EN] The focusing properties of Fresnel Zone Plates (FZPs) against frequency are analyzed in this work. It is shown that the FZP focal length depends almost linearly on the operating frequency. Focal depth and focal distortion are also considered, establishing a limit on the frequency span at which the operating frequency can be shifted. An underwater FZP ultrasound focusing system is demonstrated, and experimental results agree with the theoretical analysis and simulations.

Fresnel lensFresnel zoneOperating frequency02 engineering and technologySpan (engineering)lcsh:Chemical technology01 natural sciencesBiochemistryArticleAnalytical Chemistrylaw.inventionOpticsoperating frequencylawDistortion0103 physical sciencesLimit (music)TEORIA DE LA SEÑAL Y COMUNICACIONESFocal lengthlcsh:TP1-1185Electrical and Electronic EngineeringUnderwaterInstrumentationultrasonic lens010302 applied physicsPhysicsbusiness.industryFresnel lensultrasonic lens; Fresnel lens; focal depth; focal distortion; operating frequency021001 nanoscience & nanotechnologyfocal distortionAtomic and Molecular Physics and OpticsFISICA APLICADA0210 nano-technologybusinessfocal depthMATEMATICA APLICADASensors; Volume 17; Issue 12; Pages: 2809
researchProduct

Late gadolinium enhancement-cardiovascular magnetic resonance identifies coronary artery disease as the aetiology of left ventricular dysfunction in …

2009

Aims We evaluated the ability of late gadolinium enhancement (LGE) using cardiovascular magnetic resonance (CMR) to identify acute new-onset heart failure (HF) with left ventricular systolic dysfunction (LVSD), whether or not in relation to underlying coronary artery disease (CAD), in patients with no clinical evidence of associated ischaemic cardiomyopathy. Methods and results Hundred consecutive patients admitted with acute new-onset decompensated HF and EF ,40%, with no clinical or electrocardiographic data suggestive of CAD. The patients were classified according to the presence or absence of significant CAD (stenosis � 70% in at least one major vessel). Twenty-one patients (21%) had si…

Gadolinium DTPAMalemedicine.medical_specialtyContrast MediaCoronary Artery DiseaseCoronary AngiographySensitivity and SpecificityStatistics NonparametricCoronary artery diseaseElectrocardiographyVentricular Dysfunction LeftPredictive Value of TestsInternal medicinemedicineHumansRadiology Nuclear Medicine and imagingcardiovascular diseasesHeart FailureChi-Square DistributionReceiver operating characteristicmedicine.diagnostic_testbusiness.industryMagnetic resonance imagingGeneral MedicineMiddle Agedmedicine.diseaseMagnetic Resonance ImagingStenosisArea Under CurvePredictive value of testsHeart failureAngiographyCardiologyFemaleCardiology and Cardiovascular MedicinebusinessElectrocardiographyEuropean Journal of Echocardiography
researchProduct

Complete gangrene of penis in patient with arterial vascular disease.

2004

We present a clinical case of distal penile gangrene in a patient with peripheral vaso-occlusive disease that did not correlate with the extension of the intraoperative finding and required total penectomy. Surgical intervention at the onset of wet gangrene avoids the complication of sepsis.

GangreneMalePeripheral Vascular Diseasesmedicine.medical_specialtyArterial vascular diseasePenectomybusiness.industryUrologyBlood Coagulation DisordersMiddle Agedmedicine.diseaseWounds NonpenetratingSurgerySepsisGangrenemedicine.anatomical_structureMedicineHumansIn patientClinical casebusinessComplicationPenisPenisUrology
researchProduct

Computer-aided calculation of the molecular size of nondenatured proteins in pore-gradient gel electrophoresis

1991

A computer program written in Turbo C is described, which uses the two-step mathematical procedure published recently (Rothe, G. M., Electrophoresis 1988, 9, 307-316) to evaluate the molecular mass, Stokes' radius, spherical radius, and frictional coefficient of nondenatured proteins. The program runs on any IBM-PC or 100% compatible IBM-PC, provided the disk operating system MS-DOS or PC-DOS 3.0 or later has been installed. Functions that are permanently in use are accessible by menu. Storage and loading of data from disk and help instructions can be called by use of function keys. The program provides several tables into which inserted and calculated data is automatically integrated. Each…

Gel electrophoresisComputer programChemistryClinical BiochemistryAnalytical chemistryProteinsCharacter encodingRadiusFunction (mathematics)Table (information)BiochemistryDisk operating systemAnalytical ChemistryComputational scienceMolecular WeightModels ChemicalComputer-aidedElectrophoresis Polyacrylamide GelMathematicsSoftwareElectrophoresis
researchProduct

Transesterification of rapeseed oil over acid resins promoted by supercritical carbon dioxide

2011

The methanolysis of rapeseed oil catalyzed by commercial styrene-divinylbenzene macroporous acid resins was performed in a batch reactor at 100-140 °C and 10-46 MPa to study the effect of supercritical carbon dioxide (scCO2) on the performances of the process. Reaction temperatures of 120-140 °C were necessary to obtain high enough yields of fatty acid methyl esters. Upon addition of scCO2 faster transesterification kinetics was obtained also at the lowest investigated operating pressure (10-11 MPa), working in two fluid phase systems. Experiments performed changing the reaction time indicated that most of the esters were formed during the first 3 h. When the pressure was increased at 38-46…

General Chemical EngineeringMethanolysiKineticsBatch reactorOperating pressurePolymeric acidHeterogeneous catalysisCatalysiCatalysisHeterogeneous catalysiIon exchange resinSupercritical carbon dioxideOrganic chemistryFatty acid methyl esterRapeseed oilEsterPhysical and Theoretical ChemistryVegetable oils Supercritical fluid extractionIon-exchange resinStyreneReaction systemReaction timeBiodieselFluid phasiTwo-fluid Batch reactorSupercritical carbon dioxideEsterificationChemistryReaction kineticTransesterificationSettore ING-IND/27 - Chimica Industriale E TecnologicaFatty acidCondensed Matter PhysicsPhase behaviourTransesterificationCarbon dioxideReaction temperatureMacroporouStyrene-divinylbenzeneBiodieselEnhancement effectIon exchangeThe Journal of Supercritical Fluids
researchProduct