Search results for "Reagent"
showing 10 items of 699 documents
A clean method for flow injection spectrophotometric determination of cyclamate in table sweeteners
2005
Abstract A flow system based on the multicommutation is proposed for fast and clean determination of cyclamate. The procedure exploits the reaction of cyclamate with nitrite in acidic medium and the spectrophotometric determination of the excess of nitrite by iodometry. The flow system was designed with a set of solenoid micro-pumps to minimize reagent consumption and waste generation. The detection limit was estimated as 30 μmol L −1 (99.7% confidence level) with linear response ranging up to 3.0 mmol L −1 . The coefficient of variation was estimated as 1.7% for a solution containing 2.0 mmol L −1 cyclamate ( n = 20). About 60 samples can be analyzed per hour, consuming only 3 mg KI and 1…
Extractive-spectrophotometric determination of amphetamine in urine samples with sodium 1,2-naphthoquinone 4-sulphonate
1993
Abstract Sodium 1,2-naphthoquinone 4-sulphonate (NQS) was tested as a reagent for amphetamine in order to develop an extractive-spectrophotometric method for the drug in urine samples. The standard additions method showed the absence of proportional bias error whereas the Youden method and the two standard addition plots method showed the presence of a constant bias error [total Youden blank (TYB)]. Acceptable results were obtained by evaluating the TYB error or by using a placebo (urine sample from a normal subject). The dynamic range of concentrations was 1.4–50 mg 1−1 in urine samples and the detection limit was 0.6 mg 1−1 when 10 ml of urine sample were taken.
Derivatization of tertiary amphetamines with 9-fluorenylmethyl chloroformate for liquid chromatography: determination of N-methylephedrine.
2000
The fluorogenic reagent 9-fluorenylmethyl chloroformate (FMOC) was evaluated for the derivatization of tertiary amphetamines prior to liquid chromatographic analysis. Conditions for the derivatization were investigated, including the reaction time, the derivatization reagent concentration and the pH, using N-methylephedrine as a model compound. On the basis of these studies, a method for the quantification of N-methylephedrine is presented. The method involves derivatization with FMOC at ambient temperature and separation of the derivatives formed on a LiChrospher C18, 5 μm, 125 × 4 mm id column using acetonitrile–water gradient elution. The proposed procedure shows good linearity, accuracy…
Determination of mercury in dry-fish samples by microwave digestion and flow injection analysis system cold vapor atomic absorption spectrometry
1997
Abstract Flow injection analysis system cold vapor atomic absorption spectrometry (FIAS-CV-AAS) preceded by a wet digestion in a microwave oven, as a method for measuring mercury in fish was studied. The digestion process and conditions of the FIAS (carrier concentration: HCl 3% v v ; reducing agent: SnCl2 2% w v : filling and injection times: 8 and 25 min, respectively; and sample volumes) were optimized. The analytical parameters of the proposed method (detection limit = 7.7 ng/g; precision intraassay = 6.7%; interassay = 14.0%) demonstrates its adequacy and are similar to the ones (detection limit = 19.4 ng/g; precision intraassay = 11.2%; interassay = 15.9%) obtained using a conventiona…
A multicommuted flow system with solenoid micro-pumps for paraquat determination in natural waters.
2007
A flow system designed with solenoid micro-pumps is proposed for the determination of paraquat in natural waters. The procedure involves the reaction of paraquat with dehydroascorbic acid followed by spectrophotometric measurements. The proposed procedure minimizes the main drawbacks related to the standard chromatographic procedure and to flow analysis and manual methods with spectrophotometric detection based on the reaction with sodium dithionite, i.e. high solvent consumption and waste generation and low sampling rate for chromatography and high instability of the reagent in the spectrophotometric procedures. A home-made 10-cm optical-path flow cell was employed for improving sensitivit…
o-Dianisidine: a new reagent for selective spectrophotometric, flow injection determination of chlorine
2002
A flow injection analysis (FIA) procedure for the determination of free chlorine in industrial formulations and water samples is proposed. The manifold is provided with a gas-diffusion unit which permits the removal of interfering species and also the preconcentration of chlorine. The determination of chlorine is performed on the basis of the oxidation by o-dianisidine as a chromogenic reagent to a coloured product which can be monitored at 445 nm. The method (for a preconcentration step of 60 s) is linear over the range 0.04-1.00 mg l(-1) of chlorine, the limit of detection is 0.04 mg l(-1), the reproducibility of the procedure (as RSD of the slope) is 3.7% for a series of four independent…
Multicommutation hydride generation atomic fluorescence determination of inorganic tellurium species in milk
2005
Abstract A multicommutated flow system has been developed for hydride generation, atomic fluorescence (HG-AFS) determination of tellurate (Te VI ) and tellurite (Te IV ) in milk samples. After a batch leaching of Te by sonication at room temperature for 10 min with aqua regia, sample slurries in acidic medium were merged with sodium borohydride and HCl to obtain data on Te IV . Another portion of the acidic slurry was mixed with KBr and passed through a reaction coil introduced inside a microwave oven to reduce quantitatively Te VI to Te IV which was analyzed by HG-AFS. The detection limit was 0.57 ng g −1 in the original samples. The linear range obtained was till 4 ng ml −1 and the averag…
Development of a new method for the separation of vanadium species and chloride interference removal using modified silica capillaries-DIN-ICP-MS
2004
Abstract A new on-line method for the separation of vanadium (IV) and vanadium (V) as well as for the removal of ClO+ mass spectral interference on vanadium determination by quadrupole-ICP-MS has been developed. The sample introduction system consists of a modified fused silica capillary coupled to a direct injection nebuliser (DIN), between the solvent delivery system and the ICP. Fused silica capillaries were treated with different anion and cation exchanger reagents and were tested for the retention of Cl− and the separation of vanadium ions at μg l−1 levels. A suitable strong anion exchanger functional group (3-aminopropyltrimethoxy silane) was selected. Chlorine anions were retained in…
Influence of water sample storage protocols in chemiluminescence detection of trace elements.
2002
This paper shows the influence of different sample storage protocols, on the chemiluminescence signal of some metal ions. The storage protocols studied were: acid addition (HCl or HNO(3)) and no reagent addition to filtered and refrigerated (T=4 degrees C) samples. Light emission was produced for the chemiluminescence reaction between luminol and hydrogen peroxide in buffer carbonate conditions (pH 10.8) catalysed by Cr(III), Co(II) and Cu(II). Batch and/or flow modes in different conditions were tested. Fe(II), Fe(III), Ni(II) and Mn(II) did not give chemiluminescence in the studied conditions. A parallel study of sensitivity and selectivity was performed. Then the presence or absence of t…
Non-chromatographic speciation of mercury in mushrooms
2016
A fast, sensitive and cheap procedure has been developed for the determination of inorganic mercury (i-Hg) and organic mercury (o-Hg) in mushroom samples. The procedure is based on the use of cold vapour atomic fluorescence spectrometry (CV-AFS). The method involves the extraction of total mercury (t-Hg) with diluted HCl, followed by measurements of the corresponding Hg vapour under two different conditions: (i) directly to determine i-Hg, and (ii) after oxidation with a mixture KBr/KBrO3 to determine t-Hg. o-Hg was estimated from the difference between t-Hg and i-Hg. Previous studies were focused on the assessment of different reagents for mercury extraction and breakdown of organomercury …