Search results for "Receiver"
showing 10 items of 308 documents
Neurocognitive diagnosis and cut-off scores of the Screen for Cognitive Impairment in Psychiatry (SCIP-S)
2009
To demonstrate the ability of the Screen for Cognitive Impairment in Psychiatry (SCIP-S) to discriminate between cognitively-impaired individuals and those with adequate functioning in a sample of schizophrenic and bipolar patients, as well as in a control group.The SCIP-S, together with a full neuropsychological battery, was administered to three groups: patients with schizophrenia, patients diagnosed with bipolar disorder I, and controls. The battery scores were used to perform a standardization with respect to the control group and this served to determine the comparison groups (cognitively impaired versus unimpaired) for each of the subtests of the SCIP-S. A full analysis of decision va…
Duration of active psychosis and functional outcomes in first-episode non-affective psychosis.
2018
AbstractBackground:The duration of untreated psychosis (DUP) has been associated with negative outcomes in psychosis; however, few studies have focused on the duration of active psychotic symptoms after commencing treatment (DAT). In this study, we aimed to evaluate the effect of DUP and DAT on functional long-term outcomes (3 years) in patients with early psychosis.Methods:We evaluated the Scale for the Assessment of Positive Symptoms (SAPS) at frequent intervals for 3 years after presentation to determine the DAT for 307 individuals with first-episode psychosis together with DUP and clinical variables. The functional outcomes were assessed using the Disability Assessment Scale (DAS) at th…
Virtual Unenhanced Images at Dual-Energy CT: Influence on Renal Lesion Characterization
2019
Background Dual-energy (DE) CT allows reconstruction of virtual noncontrast (VNC) images from a single-phase contrast agent-enhanced examination, potentially reducing the need for multiphasic CT to characterize renal lesions. However, data regarding diagnostic performance of VNC images for the characterization of renal lesions are limited. Purpose To determine whether renal mass CT performed by using VNC images allows for reliable identification of renal lesions and differentiation of contrast-enhanced from unenhanced lesions, compared with unenhanced images. Materials and Methods This is a retrospective study of 293 patients (105 women [mean age, 65 years; age range, 18-91 years] and 188 m…
Salivary MMP-9 in the detection of oral squamous cell carcinoma
2017
Background Oral squamous cell carcinoma (OSCC) is the most common malignant tumour of the oral cavity. Detection of OSCC is currently based on clinical oral examination combined with histopathological evaluation of a biopsy sample. Direct contact between saliva and the oral cancer makes measurement of salivary metalloproteinase- 9 (MMP-9) an attractive alternative. Material and Methods In total, 30 OSCC patients and 30 healthy controls were included in this prospective study. Saliva samples from both groups were collected, centrifuged and supernatant fluid was subjected to ELISA for assessment of MMP-9. The median salivary MMP-9 values with interquartile range (IQR) of OSCC patients and the…
Establishing cut-points for physical activity classification using triaxial accelerometer in middle-aged recreational marathoners
2018
The purpose of this study was to establish GENEA (Gravity Estimator of Normal Everyday Activity) cut-points for discriminating between six relative-intensity activity levels in middle-aged recreational marathoners. Nighty-eight (83 males and 15 females) recreational marathoners, aged 30-45 years, completed a cardiopulmonary exercise test running on a treadmill while wearing a GENEA accelerometer on their non-dominant wrist. The breath-by-breath V̇O2 data was also collected for criterion measure of physical activity categories (sedentary, light, moderate, vigorous, very vigorous and extremely vigorous). GENEA cut-points for physical activity classification was performed via Receiver Operatin…
Evidence for a white matter lesion size threshold to support the diagnosis of relapsing remitting multiple sclerosis
2018
Abstract Background The number of white matter lesions (WML) in brain MRI is the most established paraclinical tool to support the diagnosis of multiple sclerosis (MS) and to monitor its course. Diagnostic criteria have stipulated a minimum detectable diameter of 3 mm per WML, although this threshold is not evidence-based. We aimed to provide a rationale for a WML size threshold for three-dimensional MRI sequences at 3 T by comparing patients with relapsing-remitting MS (RRMS) to control subjects (CS). Methods We analyzed MR images from two cohorts, obtained at scanners from two different vendors, each comprising patients with RRMS and CS. Both cohorts were examined with FLAIR and T1w seque…
Characterization of hypoechoic focal hepatic lesions in patients with fatty liver: diagnostic performance and confidence of contrast-enhanced ultraso…
2007
The objective of this study was to assess the diagnostic performance of contrast-enhanced ultrasound (CEUS) to characterize hypoechoic focal hepatic lesions (HFHL) in fatty liver (FL). A study group of 105 patients with FL and 105 HFHLs (52 malignant and 53 benign) underwent CEUS after SonoVue administration. Two blinded readers independently reviewed baseline ultrasound (US) and CEUS scans and classified each lesion as malignant or benign on a five-point scale of confidence, and recorded whether further imaging work-up was needed. Sensitivity, specificity, areas under the receiver operating characteristic (ROC) curve (A (z)), and interobserver agreement were calculated. We observed that th…
Texture analysis in susceptibility-weighted imaging may be useful to differentiate acute from chronic multiple sclerosis lesions.
2020
To evaluate the diagnostic performance of texture analysis (TA) applied on non-contrast-enhanced susceptibility-weighted imaging (SWI) to differentiate acute (enhancing) from chronic (non-enhancing) multiple sclerosis (MS) lesions. We analyzed 175 lesions from 58 patients with relapsing-remitting MS imaged on a 3.0 T MRI scanner and applied TA on T2-w and SWI images to extract texture features. We evaluated the presence or absence of lesion enhancement on T1-w post-contrast images and performed a computational statistical analysis to assess if there was any significant correlation between the texture features and the presence of lesion activity. ROC curves and leave-one-out cross-validation…
Blood pressure for outcome prediction and risk stratification in acute pulmonary embolism.
2015
Abstract Introduction Risk stratification of patients with acute pulmonary embolism (PE) is crucial in deciding appropriate therapy management. Blood pressure (BP) is rapidly available and a reliable parameter. We aimed to investigate BP for short-term outcome in acute PE. Materials and methods Data of 182 patients with acute PE were analyzed retrospectively. Logistic regression models were calculated to investigate associations between BP and in-hospital-death as well as myocardial necrosis. Moreover, receiver operating characteristic (ROC) curves and cutoff values for systolic and diastolic BPs predicting in-hospital death and myocardial necrosis were computed. Results A total of 182 pati…
Solid bone tumors of the spine: Diagnostic performance of apparent diffusion coefficient measured using diffusion-weighted MRI using histology as a r…
2017
Purpose To assess the diagnostic performance of mean apparent diffusion coefficient (mADC) in differentiating benign from malignant bone spine tumors, using histology as a reference standard. Conventional magnetic resonance imaging (MRI) sequences have good reliability in evaluating spinal bone tumors, although some features of benign and malignant cancers may overlap, making the differential diagnosis challenging. Materials and Methods In all, 116 patients (62 males, 54 females; mean age 59.5 ± 14.1) with biopsy-proven spinal bone tumors were studied. Field strength/sequences: 1.5T MR system; T1-weighted turbo spin-echo (repetition time / echo time [TR/TE], 500/13 msec; number of excitatio…