Search results for "Reference Standards"
showing 10 items of 156 documents
An interlaboratory study as useful tool for proficiency testing of chemical oxygen demand measurements using solid substrates and liquid samples with…
2009
In 2008, the first Proficiency Testing Scheme of Chemical Oxygen Demand (1stCOD-PTADG) was conducted to assess the results obtained for different research groups whose field work is mainly anaerobic digestion. This study was performed using four samples, two solid samples as raw materials and two solid samples to prepare high concentration suspended solid solutions. Invitations were sent to a large number of laboratories, mainly to anaerobic digestion research groups. Finally, thirty labs from sixteen countries agreed to participate, but for different reasons four participants could not send any data. In total, twenty-six results were reported to the COD-PT coordinator. This study showed th…
Predicting school students’ physical activity intentions in leisure-time and school recess contexts: Testing an integrated model based on self-determ…
2021
BackgroundIdentifying psychological correlates of children's physical activity intentions may signpost potentially modifiable targets for interventions aimed at promoting physical activity participation. School recess and leisure-time outside of school are appropriate contexts in which such interventions may be delivered. However, few studies have identified correlates of physical activity intentions in these environments. Examining correlates in these contexts may provide formative evidence on which to base interventions to promote physical activity.PurposeThe current study adopted an integrated theoretical model to test relations between motivational constructs from self-determination the…
Application of solid-phase microextraction for determining phenylurea herbicides and their homologous anilines from vegetables.
2004
Abstract Residues of metobromuron, monolinuron and linuron herbicides and their aniline homologous were analyzed in carrots, onions and potatoes by solid-phase microextraction (SPME) performed with a polyacrylate fiber. A juice was obtained from food samples that were further diluted, and an aliquot was extracted after sodium chloride (14%) addition and pH control. At pH 4 only the phenylureas were extracted. A new extraction at pH 11 allowed the extraction of phenylureas plus homologous aniline metabolites. Determination was carried out by gas chromatography with nitrogen–phosporus detection (NPD) the identity of the determined compounds was studied by gas chromatography–mass spectrometry.…
Application of matrix solid-phase dispersion to the determination of a new generation of fungicides in fruits and vegetables.
2002
A method based on matrix solid-phase dispersion (MSPD) and gas chromatography to determine eight fungicides in fruits and vegetables is described. Fungicide residues were identified and quantified using nitrogen-phosphorus detection and electron-capture detection connected in parallel and confirmed by mass spectrometric detection. The method required 0.5 g of sample, C18 bonded silica as dispersant sorbent, silica as clean-up sorbent and ethyl acetate as eluting solvent. Recoveries from spiked orange, apple, tomato, artichoke, carrot and courgette samples ranged from 62 to 102% and relative standard deviations were less than 15% in the concentration range 0.05-10 mg kg(-1). Detection and qu…
Determination of dithiocarbamates and metabolites in plants by liquid chromatography–mass spectrometry
2004
Abstract A quantitative matrix solid-phase dispersion and liquid chromatography–atmospheric pressure chemical ionization mass spectrometry (LC–APCI–MS) method is outlined for the simultaneous analysis of dithiocarbamates (DTCs) and their degradation products in plants. Compounds analyzed are dazomet, disulfiram, thiram and the metabolites ethylenthiourea and propylenthiourea. The performance of two different sample preparation protocols, the proposed one and other based on solid-phase extraction, as well as, of both atmospheric pressure ionization sources, APCI and electrospray, were compared. The effect of several parameters on the extraction, separation and detection was studied. Dithioca…
Determination of anti GAD65 autoantibodies with an ELISA before and after standardization with the new international reference serum
2009
The serum of a stiff-man syndrome patient was declared international GAD reference standard at the "1st GAD Antibody Workshop" held at the "12th International Immunology and Diabetes Workshop" in Orlando, Florida, USA 1993. A comparative study was performed with 123 diabetic and non-diabetic patients to evaluate whether standardization of this reference serum had changed the properties of a commercially available ELISA assay. All samples classified positive with the old test were confirmed with the new assay. Four additional samples with high "normal" values became positive with the new test. One of them was a control person having a family history of diabetes and genetic loci DR4/DR11. The…
Multi-residue analysis of 30 currently used pesticides in fine airborne particulate matter (PM 2.5) by microwave-assisted extraction and liquid chrom…
2009
A confirmatory and rapid procedure has been developed for the determination of 30 currently used pesticides (CUP) in fine airborne particulate matter (PM 2.5) at trace level. The proposed method includes extraction of PM 2.5-bound pesticides by microwave-assisted extraction (MAE) followed by a direct injection into LC-MS/MS. The main parameters affecting the MAE extraction (time, temperature and volume of solvent) were optimised using statistical design of experiments (DoE). The matrix effect was also evaluated. Recoveries ranged from 72 to 109% and the limit of quantification (LoQ) was 32.5 pg m(-3) for chlorpyrifos, 13.5 pg m(-3) for fenhexamid, imazalil and prochloraz, and 6.5 pg m(-3) f…
Source and Nature of Inhaled Atmospheric Dust from Trace Element Analyses of Human Bronchial Fluids
2011
International audience; Rapid volcanic eruptions quickly ejecting large amounts of dust provoke the accumulation of heavy metals in people living in surrounding areas. Analyses of bronchoalveolar lavage samples (BAL) collected from people exposed to the paroxysmal 2001 Etna eruption revealed a strong enrichment of many toxic heavy metals. Comparing the BAL to the dust composition of southeastern Sicily, we found that only V, Cr, Mn, Fe, Co, and U enrichment could be related to the volcanic event, whereas Ni, Cu, Cd, and Pb contents come from the dissolution of particles of anthropogenic origin. Furthermore, the nature of these inhaled anthropogenic particles was revealed by anomalous La and…
Global retention models and their application to the prediction of chromatographic fingerprints
2020
Abstract The resolution of samples containing unknown compounds of different nature, or without standards available, as is the case of chromatographic fingerprints, is still a challenge. Possibly, the most problematic aspect that prevents systematic method development is finding models that describe without bias the retention behaviour of the compounds in the samples. In this work, the use of global models (able to describe the whole sample) is proposed as an alternative to the use of individual models for each solute. Global models contain parameters that are specific for each solute, while other parameters ‒related to the column and solvent‒ are common for all solutes. A special regressio…
Respiratory mechanics measured by forced oscillations during mechanical ventilation through a tracheal tube
2011
The forced oscillation technique (FOT) allows the measurement of respiratory mechanics in the intensive care setting. The aim of this study was to compare the FOT with a reference method during mechanical ventilation through a tracheal tube. The respiratory impedance spectra were measured by FOT in nine anaesthetized pigs, and resistance and compliance were estimated on the basis of a linear resistance-compliance inertance model. In comparison, resistance and compliance were quantified by the multiple linear regression analysis (LSF) of conventional ventilator waveforms to the equation of motion. The resistance of the sample was found to range from 6 to 21 cmH(2)O s l(-1) and the compliance…