Search results for "Reflection"
showing 10 items of 645 documents
Ionic-liquid doped polymeric composite as passive colorimetric sensor for meat freshness as a use case.
2020
Abstract A composite membrane containing 1,2-naphthoquinone-4-sulfonic acid sodium salt (NQS) embedded in an ionic liquid (IL)- polydimethylsiloxane (PDMS)- tetraethyl orthosilicate (TEOS)- SiO2 nanoparticles (NPs) polymeric matrix is proposed. The selected IL was 1-methyl-3-octylimidazolium hexafluorophosphate (OMIM PF6). It is demonstrated that ILs chemical additives of PDMS influenced the sol-gel porosity. The sensor analytical performance for ammonia atmospheres has been tested as a function of sampling time (between 0.5 and 312 h), temperature (25 °C and 4 °C) and sampling volume (between 2L and 22 mL) by means of diffuse reflectance measurements and sensor photos, which can be registe…
Simulation en santé et médecine interne : quel avenir ?
2018
Simulation-based learning (SBL) is developing rapidly in France and the question of its use in the teaching of internal medicine (IM) is essential. While HAS encourages its integration into medical education, French Young Internists (AJI) set up a working group to reflect on the added-value of this tool in our specialty. Different sorts of SBL exist: human, synthetic and electronic. It enables student to acquire and evaluate technical skills (strengths, invasive procedures, etc.) and non-technical skills (relational, reasoning…). The debriefing that follows the simulation session is an essential time in pedagogical terms. It enables the acquisition of knowledge by encouraging the students' …
Dipotassium 4,4'-(hexane-3,4-di-yl)bis-(benzene-sulfonate) dihydrate.
2008
The anion of the title compound, also called sygethin dihydrate, 2K(+)·C(18)H(20)O(6)S(2) (2-)·2H(2)O, has crystallographic inversion symmetry. The K(+) cation is surrounded by eight O atoms in a distorted cubic coordination geometry, forming extended K-O-S networks. There are also O-H⋯O hydrogen bonds.
La construcció del coneixement gramatical en aprenents d'educació primària i secundària: algunes aproximacions a l'aprenentatge del verb
2017
El verb és una de les categories que una gramàtica escolar ha d’abordar necessàriament, tant pel que fa al coneixement de la noció i de la seva relació amb altres categories, com per la funció fonamental que pren en l’escriptura. En aquest article presentem tres recerques que descriuen el procés d’aprenentatge que els alumnes de primària i de secundària segueixen a l’hora d’aprendre continguts vinculats amb el verb: el temps del present, el mode verbal i la complementació verbal. Aquests treballs mostren quines estratègies desenvolupen els aprenents i quins obstacles han d’afrontar per desenvolupar un raonament gramatical. Dels estudis es desprèn que determinades intervencions didàctiques (…
Active Lighting Applied to Shape from Polarization
2006
We present a new way of solving the ambiguity that appears in the shape from polarization method. This ambiguity, concerning the normals orientation of the surface, was previously solved thanks to a propagation algorithm. In this paper, the ambiguity is solved thanks to a special active lighting. This method is less time computing and is more robust to noise acquisition. We first demonstrate how to compute the right normals on the whole surface. Then, we show an application on the 3D reconstruction of a specular metallic object made by stamping and polishing.
Application of total internal reflexion fluorescence microscopy for studying pH changes in an occluded electrochemical cell: Development of a wavegui…
2006
A device for pH mapping derived from optical sensors similar to total internal reflection fluorescence microscopy (TIRFM) has been developed for future possible applications in the field of localized corrosion. The sensing principle is the increase of the fluorescent yield of the fluorescein with the pH of the medium. The basic principle of this sensor is based on the excitation of a fluorescent silica polymer film of nanometre dimensions, deposited by sol–gel method on a waveguiding layer. The total internal reflexion conditions creates an evanescent wave which interacts with the molecules trapped in the silica layer. A conventional microscope located above the sample collects the fluoresc…
Intraosseous monitoring of drilling in lumbar vertebrae by ultrasound: An experimental feasibility study.
2016
The rationale for this project is to evaluate the efficiency of a novel sonographic method for measurements of interosseous distances. The method utilizes a propagating ultrasonic beam through aqueous milieu which is directed as a jet into a drilled tract. We used a plastic model of human L5 vertebra and ex vivo specimen of L5 porcine vertebra and generated 2 mm in diameter tracts in vertebral pedicles. The tracts were created in the "desired" central direction and in the "wrong" medial and lateral directions. The drilled tracts and the residual, up to opposite cortex, distances were measured sonographically and mechanically and compared statistically. We show that "true" mechanical measure…
Preparation of organic monolithic columns in polytetrafluoroethylene tubes for reversed-phase liquid chromatography
2017
[EN] In this work, a method for the preparation and anchoring of polymeric monoliths in a polytetrafluoroethylene (PTFE) tubing as a column housing for microbore HPLC is described. In order to assure a covalent attachment of the monolith to the inner wall of the PTFE tube, a two-step procedure was developed. Two surface etching reagents, a commercial sodium naphthalene solution (Fluoroetch®), or mixtures of H2O2 and H2SO4, were tried and compared. Then, the obtained hydroxyl groups on the PTFE surface were modified by methacryloylation. Attenuated total reflectance Fourier-transform infrared (ATR-FTIR) spectroscopy and scanning electron microscopy (SEM) confirmed the successful modification…
Determination of vinegar acidity by attenuated total reflectance infrared measurements through the use of second-order absorbance-pH matrices and par…
2007
Univariate (zero-order), multivariate (first-order) and multiway (second-order) calibrations were assayed for the determination of vinegar acidity using a mechanized procedure based upon vibrational spectroscopy and the emerging multicommutation methodology. The second-order methodology relies on the use of a flow system based on multicommutation and binary sampling. The flow network comprises a set of three-way solenoid valves, computer-controlled to provide facilities to handle the sample and to generate a time-dependent pH gradient using two carrier solutions. The procedure is based on the volumetric fraction variation approach that maintains the same volume of sample solution and dynami…
Combination of mid- and near-infrared spectroscopy for the determination of the quality properties of beers
2006
Abstract The combination of infrared (MIR) and near-infrared (NIR) spectroscopy has been employed for the determination of important quality parameters of beers, such as original and real extract and alcohol content. A population of 43 samples obtained from the Spanish market and including different types of beer, was evaluated. For each technique, spectra were obtained in triplicate. In the case of NIR a 1 mm pathlength quartz flow cell was used, whereas attenuated total reflectance measurements were used in MIR. Cluster hierarchical analysis was employed to select calibration and validation data sets. The calibration set was composed of 15 samples, thus leaving 28 for validation. A critic…