Search results for "Refraction"
showing 10 items of 200 documents
Proposal of a new diffractive corneal inlay to improve near vision in a presbyopic eye
2020
[EN] A new class of diffraction-based corneal inlays for treatment of presbyopia is described. The inlay is intended to achieve an improvement of the near focus quality over previous designs. Our proposal is a two-zone hybrid device with separated amplitude and phase areas having a central aperture and no refractive power. An array of micro-holes is distributed on the surface of the inlay conforming a binary photon sieve. In this way, the central hole of the disk contributes to the zero order of diffraction, and the light diffracted by the micro-holes in the peripheral photon sieve produces a real focus for near vision. We employed ray-tracing software to study the performance of the new in…
Diffraction-managed superlensing using metallodielectric heterostructures
2012
We show that subwavelength diffracted wave fields may be managed inside multilayered plasmonic devices to achieve ultra-resolving lensing. For that purpose we first transform both homogeneous waves and a broad band of evanescent waves into propagating Bloch modes by means of a metal/dielectric (MD) superlattice. Beam spreading is subsequently compensated by means of negative refraction in a plasmon-induced anisotropic effective-medium that is cemented behind. A precise design of the superlens doublet may lead to nearly aberration-free images with subwavelength resolution in spite of using optical paths longer than a wavelength. This research was funded by the Spanish Ministry of Economy and…
Treatment of grazing-incidence small-angle X-ray scattering data taken above the critical angle
2001
The equations taking into account refraction at the sample surface in grazing-incidence small-angle X-ray scattering (GISAXS) when the angle between the incoming beam and the sample surface is slightly larger than the critical angle are derived and discussed. It is demonstrated that the refraction of both the incoming and the scattered beam at the sample surface affects the GISAXS pattern and that, when a planar bidimensional detector perpendicular to the incoming beam is used, the effect depends on the azimuthal detector angle. The smearing of the pattern depending on the size of the illuminated sample area in grazing incidence is estimated by simulations with Cauchy functions of different…
New method for real-time dynamic focusing through interfaces
2013
[EN] In nondestructive evaluation (NDE) a coupling medium (wedge) is frequently inserted between the array probe and the object being evaluated. In this situation, focal law computing is complicated by the refraction effects at the interface. Furthermore, there are not known techniques to perform dynamic focusing by hardware in these conditions. This work addresses these problems by following a two-step procedure. First, a virtual array that operates in a single medium with nearly equivalent time-of-flight to the foci is obtained. Then, simple hardware is proposed to perform dynamic focusing in real-time. It operates with arrays of any geometry as required by the virtual array in presence o…
Coseismic Damage at an Archaeological Site in Sicily, Italy: Evidence of Roman Age Earthquake Surface Faulting
2018
Archaeoseismology can provide a useful chronological tool for constraining earthquakes and documenting significant evidence that would otherwise be lost. In this paper, we report a case of surface faulting on ancient man-made structures belonging to the archaeological site of Santa Venera al Pozzo situated along the eastern flank of Mt. Etna volcano in eastern Sicily (southern Italy), which is affected by well-developed tectonic faults. Geological surveys highlight a set of fractures affecting the archaeological ruins, suggesting the occurrence of a capable fault zone across the area. An integrated geophysical survey was carried out in order to identify the main subsurface tectonic disconti…
Geophysical and geotechnical investigations to support the restoration project of the Roman ‘Villa del Casale’, Piazza Armerina, Sicily, Italy
2011
A multidisciplinary geophysical and geotechnical study, including some non-invasive geophysical applications, was carried out during the restoration of the ‘Villa del Casale’, a Roman villa discovered near Piazza Armerina (Sicily, Italy) in 1929, famous for its Roman floor mosaics. The project aims were to characterize the geology of the subsoil and provide information for solving the main building structural problems including the subsidence of some parts of the floor and the detachment of the tesserae (i.e., the tiles) of the mosaics. Another goal was the detailed study of the underground structures of the Corridor of the Great Hunt, a part of the villa strongly affected by subsidence and…
Application of non-invasive seismic techniques for the characterisation of a gravity concrete dam
2020
The use of non-invasive investigation methods is becoming frequent as a support for the monitoring of water reservoirs and for the management of dam safety. In this context, geophysical techniques are much less invasive than geotechnical tests and allow to obtain two-dimensional or three-dimensional representations of the mechanical parameters of an engineering structure. A case of application of constrained inversion and joint interpretations of non-invasive seismic techniques is discussed, in order to monitor the Dirillo gravity concrete dam, in Sicily. To investigate the foundation soil, a stratigraphic borehole and a vertical seismic profile, carried out in the same hole, were used to c…
Refraktion, Vorderkammertiefe, Dezentrierung und Tilt nach Implantation monofokaler und multifokaler Silikonlinsen
2001
Hintergrund. Ziel der prospektiven Studie war die Analyse von Refraktion, Vorderkammertiefe, Dezentrierung und Verkippung (Tilt) nach Implantation monofokaler (MONO) und multifokaler (MIOL) Intraokularlinsen (IOL). Patienten und Methode. Bei 103 Augen von 103 Patienten wurde entweder eine dreistuckige monofokale oder multifokale Silikon-IOL implantiert. Vorderkammertiefe (ACD), IOL-Dezentrierung und -Tilt wurden mittels Retroilluminationsfotografie und Scheimpflug-Aufnahmen objektiv quantifiziert. Die Untersuchungen einschlieslich Ermittlung der sujektiven Refraktion wurden praoperativ sowie postoperativ nach 1 Woche und nach 6 Monaten vorgenommen. Ergebnisse. Im Bereich von ±1 dpt um die Z…
Removal of Viscoelastic Substances
2000
All viscoelastics should be completely removed from the eye to reduce the likelihood of increased intraocular pressure. Should OVD retention behind the IOL occur, an unstable refraction could result. Residual high molecular viscous substance is transported away through the trabecular meshwork, with delay, possibly resulting in a protracted postoperative IOP increase. To aspirate viscoelastics various techniques as well as instruments with different aspiration/irrigation adjustments have been proposed, a few of which will be described here. Viscoelastic removal involving the simultaneous irrigation and aspiration through a single cannula (Nevyas, 1987) or two separate cannulas (Brauweiler, 1…
Femtosecond laser for residual refractive error correction after refractive lens exchange with multifocal intraocular lens implantation.
2008
Purpose To assess visual and refractive outcomes of femtosecond laser for residual refractive error correction after refractive lens exchange (RLE) with multifocal intraocular lens (IOL) implantation. Design Prospective, nonrandomized, masked observational case series (self-controlled). Methods Fifty-three eyes of 31 consecutive patients were submitted to femtosecond laser surgery after RLE with multifocal IOL implantation. Patients showed an average manifest refractive error (D) of M , 0.200 ± 0.490; J 0 , −0.051 ± 0.532; and J 45 , −0.007 ± 0.371. Visual acuity (VA) was measured at distance and near vision before and six months after the surgery. Results At six months after surgery, mean …