Search results for "Refractive"
showing 10 items of 559 documents
Pressure dependence of the refractive index in wurtzite and rocksalt indium nitride
2014
We have performed high-pressure Fourier transform infrared reflectance measurements on a freestanding InN thin film to determine the refractive index of wurtzite InN and its high-pressure rocksalt phase as a function of hydrostatic pressure. From a fit to the experimental refractive-index curves including the effect of the high-energy optical gaps, phonons, free carriers, and the direct (fundamental) band-gap in the case of wurtzite InN, we obtain pressure coefficients for the lowfrequency (electronic) dielectric constant e1 . Negative pressure coefficients of -8.8 × 10-2 GPa-1 and -14.8 × 10-2 GPa-1 are obtained for the wurtzite and rocksalt phases, respectively. The results are discussed …
Two-wave mixing at 854 nm in BaTiO3:Rh planar waveguide implanted with He+
2001
Abstract Guided waves at 854 nm are observed in a BaTiO 3 :Rh waveguide fabricated by the technique of ion-beam implantation. The photorefractive interaction between two guided modes is demonstrated and characterized. The experiments reveal that the gain direction is reversed in the guiding layer in comparison with that in the bulk. A maximum gain of 24 cm −1 is achieved.
Dispersion-optimized multicladding silicon nitride waveguides for nonlinear frequency generation from ultraviolet to mid-infrared
2016
Nonlinear frequency conversion spanning from the ultraviolet to the mid-infrared (beyond 2.4 μm) is experimentally demonstrated in multicladding silicon nitride (𝑆𝑖𝑋𝑁𝑌) waveguides. By adjusting the waveguide cross-section the chromatic dispersion is flattened, which enhances both the efficiency and the bandwidth of the nonlinear conversion. How accurately the dispersion is tailored is assessed through chromatic dispersion measurements and an experiment/simulation comparison of the dispersive waves' wavelength locations. Undesirable fluctuations of both the refractive index and the dimensions of the waveguide during the fabrication process result in a dispersion unpredictability of at l…
Mach-Zehnder interferometer implementation for thermo-optical and Kerr effect study
2018
Scientific Research Project for Students and Young Researchers Nr. SJZ/2016/10; National Research Program “Multifunctional Materials and Composites, Photonics and Nanotechnology” (IMIS2) project “Photonics and materials for photonics”.
Origin of Kerr effect: investigation of solutions by polarization dependent Z-scan
2020
This material is based upon work supported by the ERDF 1.1.1.1 activity project No. 1.1.1.1/16/A/046 “Application assessment of novel organic materials by prototyping of photonic devices”.
Nonlinear optical properties of silver nanoparticles: separating thermo-optical and Kerr effects
2021
In this paper, we present a study on thermo-optical effect in core-shell silver/thiol-termination ligand nanoparticles. Nanoparticles were dissolved in Dichloromethane. Experimental measurements were carried out using a Z-scan setup. As laser sources we used two 1064 nm lasers: i) 28 ps pulse width laser with 1000 Hz pulse repetition rate; ii) 8 ns pulse width laser with changeable pulse repetition rate 200 – 40 000 Hz. To study what processes lead to refractive index changes we used the polarization-resolved Z-scan method. Comparing ps and ns results showed that response time of single pulse thermal effects for organic solvents depends on beam size while for nanoparticles it corresponds to…
Volume integrated phase modulator based on funnel waveguides for reconfigurable miniaturized optical circuits.
2015
We demonstrate the integration of a miniaturized 30(x) μm × 30(y) μm × 2.7(z) mm electro-optic phase modulator operating in the near-IR (λ = 980 nm) based on the electro-activation of a funnel waveguide inside a paraelectric sample of photorefractive potassium lithium tantalate niobate. The modulator forms a basic tassel in the realization of miniaturized reconfigurable optical circuits embedded in a single solid-state three-dimensional chip.
Kinetics of Photorefractive Light Scattering in LiNbO3:Cu and LiNbO3:Zn Single Crystals
2011
Results of studies of the kinetics of photorefractive light scattering (PRLS) in optically nonlinear congruent single crystals of lithium niobate (LiNbO3, Li/Nb = 0.946) containing multivalent cation admixtures of Cu [0.015 mass %] (“photorefractive”) and Zn [0.5 mass %] (“non-photorefractive”) are reported. The shape of the PRLS indicatrix is found to be different in case of Cu and Zn admixtures. However, the angular widening of the indicatrix in both cases reaches its stationary value faster at higher laser radiation intensities. The PRLS is found to depend on the site of the ingot from which the samples are cut – an evidence of non-uniform distribution of defects with localised electrons…
Near-field scanning optical microscopy to study nanometric structural details of LiNbO3 Zn-diffused channel waveguides
2008
A near-field scanning optical microscope (NSOM) is used to perform structural and optical characterization of the surface layer after Zn diffusion in a channel waveguide fabricated on lithium niobate. A theoretical approach has been developed in order to extract refractive index contrast from NSOM optical transmission measurements (illumination configuration). As a result, different solid phases present on the sample surface can be identified, such as ZnO and ZnNb2O6. They appear like submicrometric crystallites aligned along the domain wall direction, whose origin can be ascribed to some strain relaxation mechanism during the annealing process after Zn diffusion. Jose.Canet-Ferrer@uv.es
Partially Coherent Optical Diffraction Tomography Toward Practical Cell Study
2021
Optical diffraction tomography (ODT) is a computational imaging technique based on refractive index (RI) contrast. Its application for microscopic imaging of weakly absorbing and scattering samples has been demonstrated by using a specially designed holographic microscope with angular scanning of the coherent sample illumination direction. Recently, an alternative low cost technique based on partially coherent sample illumination (PC-ODT), which is compatible with the conventional wide-field transmission microscope, has been established. In this case, the 3D refractive index distribution of the sample is obtained by deconvolution from a single stack of through-focus intensity images. The pe…