OCT for Assessing Artificial Tears Effectiveness in Contact Lens Wearers

2011

PURPOSE: To apply a commercially available high-resolution spectral domain optical coherence tomographer (SOCT) to assess the change in tear volume after application of a new artificial tears formulation specifically developed for contact lens (CL) users. METHODS: Twenty OD from young healthy CL wearers (mean age, 24.7 ± 3.5 years) with refractive errors ranging from -0.75 to -2.50 D (mean, -1.56 ± 0.69 D) were examined. All subjects were fitted with Focus Dailies CL (Ciba Vision), and two drops of Blink Contacts (AMO), lubricating formulation specifically developed for CL wearers, were instilled after baseline measures. Tear meniscus volume (TMV) was measured immediately after and 1 min, 1…

Adultmedicine.medical_specialtyContact Lensesmedicine.medical_treatmentMeniscus (anatomy)Tear volumeYoung AdultRegular distributionOphthalmologyImage Processing Computer-AssistedHumansMedicinebusiness.industryRepeated measures designContact Lenses HydrophilicRefractive ErrorsContact lensOphthalmologyArtificial tearsmedicine.anatomical_structureTear meniscusOftalmologíaDry Eye SyndromesEyelidOphthalmic SolutionsbusinessTomography Optical CoherenceFollow-Up StudiesOptometryOptometry and Vision Science
researchProduct

Prevalence of general binocular dysfunctions in a population of university students.

1997

Although some authors report that the prevalence of general binocular dysfunctions (nonstrabismic) for nonpresbyopes in the clinical population is greater than any condition except refractive error, limited research is available to support this statement. This clinical study determined the presence and clinical implications of these conditions in a population of university students with heavy near visual demands.From a group of second year students who were given a thorough eye examination, 65 students were selected. The criteria for selection were the absence of significant uncorrected refractive error, healthy eyes, and no strabismus or amblyopia.32.3% of the subjects showed general binoc…

Adultmedicine.medical_specialtyRefractive errorConvergence insufficiencyUniversitiesAccommodative insufficiencyPopulationVision DisordersClinical studyEpidemiologymedicinePrevalenceHumanseducationStudentseducation.field_of_studyVision Binocularbusiness.industryAccommodation OcularConvergence Ocularmedicine.diseaseOphthalmologySpainOptometrybusinessPsychologyAccommodationBinocular visionOptometryClinical psychologyOptometry and vision science : official publication of the American Academy of Optometry
researchProduct

Femtosecond laser versus mechanical keratome LASIK for myopia.

2005

To assess efficacy, safety, predictability, stability, and changes in corneal higher-order aberrations (CHOAs) and contrast sensitivity (CS) after a femtosecond laser for LASIK and standard LASIK for myopia.Prospective, randomized, comparative clinical study.Two hundred eyes of 100 consecutive patients who underwent LASIK treatment using the VISX S2 laser system. A femtosecond laser for flap creation was used in 100 eyes (50 patients; spherical equivalent [SE], -2.85+/-1.79 diopters [D]), and a mechanical microkeratome was used in 100 eyes (50 patients; SE, -2.90+/-1.63 D).Uncorrected visual acuity (UCVA), best spectacle-corrected visual acuity (BSCVA), manifest refraction, CS by means of t…

Adultmedicine.medical_specialtyRefractive errorVisual acuitygenetic structuresmedicine.medical_treatmentKeratomileusis Laser In SituVisual AcuityKeratomileusisSurgical FlapsContrast SensitivityCorneaTonometry OcularMicrokeratomemedicineMyopiaHumansProspective StudiesDioptremedicine.diagnostic_testbusiness.industryLasersLASIKCorneal Topographymedicine.diseaseCorneal topographyeye diseasesPhotorefractive keratectomySurgeryOphthalmologyTreatment Outcomesense organsmedicine.symptombusinessOphthalmology
researchProduct

The effect of simulated normal and amblyopic higher-order aberrations on visual performance.

2012

Purpose To study the effect of simulated amblyopic and normal higher-order aberrations on visual performance of normal eyes. Methods To assess visual function, an adaptive optics visual simulator was used to compensate volunteers' ocular aberrations and simulate the wavefront aberration patterns found in healthy and amblyopic eyes in 7 healthy individuals. Visual acuity for high (100%), medium (50%), and low (10%) contrast and contrast sensitivity at 10, 20, and 25 cycles per degree (cpd) were measured after simulation of both pattern aberrations. The modulation transfer function and the point spread function were computed based on the aberration data. All measures were taken for 3 and 5.5 …

Adultmedicine.medical_specialtyVisual acuityCorneal Wavefront Aberrationgenetic structuresmedia_common.quotation_subjectVisual AcuityAmblyopiaPupilContrast SensitivityYoung AdultOphthalmologyOptical transfer functionmedicineContrast (vision)Humansmedia_commonContrast levelbusiness.industryAberrometryPupil sizeAstigmatismPupilModels TheoreticalRefractive Errorseye diseasesOphthalmologyAberrations of the eyePediatrics Perinatology and Child HealthOptometrysense organsSpatial frequencymedicine.symptombusinessJournal of AAPOS : the official publication of the American Association for Pediatric Ophthalmology and Strabismus
researchProduct

Contrast sensitivity after LASIK flap creation with a femtosecond laser and a mechanical microkeratome

2007

ABSTRACT PURPOSE: To compare the effects on contrast sensitivity of the IntraLase femtosecond laser for flap creation (IntraLASIK) and standard LASIK for myopia. METHODS: Two hundred eyes of 100 consecutive patients underwent LASIK treatment using the VISX S2 laser system. The femtosecond laser (15 kHz IntraLase) was used for flap creation in 100 eyes (50 patients) and a mechanical microkeratome (Carriazo-Barraquer) was used in 100 eyes (50 patients). Best spectacle-corrected contrast sensitivity was measured before and 6 months postoperatively in the IntraLASIK and mechanical LASIK groups. The IntraLASIK and mechanical LASIKinduced changes in contrast sensitivity were compared under photop…

Adultmedicine.medical_specialtygenetic structuresMesopic visionmedicine.medical_treatmentmedia_common.quotation_subjectKeratomileusis Laser In SituSurgical Flapslaw.inventionContrast SensitivitylawMicrokeratomeOphthalmologymedicineHumansContrast (vision)media_commonbusiness.industryLASIKEquipment DesignRefractive ErrorsLasereye diseasesRefractive Surgical ProceduresSurgeryOphthalmologyTreatment OutcomeFemtosecondSurgerysense organsbusinessSensitivity (electronics)Follow-Up StudiesPhotopic vision
researchProduct

Effective broadband refractive index retrieval by a white light optical particle counter.

2009

A new approach to retrieve the effective broadband refractive indices (nbroad,eff) of aerosol particles by a white light aerosol spectrometer (WELAS) optical particle counter (OPC) is presented. Using a tandem differential mobility analyzer (DMA)-OPC system, the nbroad,eff are obtained for both laboratory and field applications. This method was tested in the laboratory using substances with a wide range of optical properties. With the obtained nbroad,eff, WELAS aerosol size distributions can be corrected. Therefore, this method can be used for instrument calibration in both laboratory and field measurements. The retrieved effective broadband refractive indices for the scattering aerosols we…

AerosolsSpectrometerLightScatteringChemistryAtmosphereSpectrum AnalysisAnalytical chemistryGeneral Physics and AstronomyAerosolPhotometryWavelengthRefractometryDifferential mobility analyzerCalibrationParticulate MatterGasesPhysical and Theoretical ChemistryParticle SizeParticle counterRefractive indexEnvironmental MonitoringPhysical chemistry chemical physics : PCCP
researchProduct

A Refractive Index Sensor Based on the Resonant Coupling to Cladding Modes in a Fiber Loop

2013

We report an easy-to-build, compact, and low-cost optical fiber refractive index sensor. It consists of a single fiber loop whose transmission spectra exhibit a series of notches produced by the resonant coupling between the fundamental mode and the cladding modes in a uniformly bent fiber. The wavelength of the notches, distributed in a wavelength span from 1,400 to 1,700 nm, can be tuned by adjusting the diameter of the fiber loop and are sensitive to refractive index changes of the external medium. Sensitivities of 170 and 800 nm per refractive index unit for water solutions and for the refractive index interval 1.40-1.442, respectively, are demonstrated. We estimate a long range resolut…

All-silica fiberMaterials scienceTransducersPhysics::Opticslcsh:Chemical technologyBiochemistryGraded-index fiberRessonància magnètica nuclearArticleAnalytical ChemistryDouble-clad fiberOpticsFiber Optic Technologylcsh:TP1-1185Electrical and Electronic EngineeringInstrumentationbusiness.industryoptical fiber devicesrefractive index sensormode couplingEquipment DesignLong-period fiber gratingCladding (fiber optics)Atomic and Molecular Physics and OpticsÒptica Aparells i instrumentsEquipment Failure AnalysisSolutionsRefractometryNormalized frequency (fiber optics)businessStep-index profilePhotonic-crystal fiberSensors (Basel, Switzerland)
researchProduct

Real-time polarimetric biosensing using macroporous alumina membranes

2013

We report the first demonstration of real-time biosensing in free standing macroporous alumina membranes. The membranes with their 200 nm diameter pores are ideal candidates for biosensing applications where fast response times for small sample volumes are needed as they allow analytes to flow through the pores close to the bioreceptors immobilized on the pores walls. A bulk refractive index sensitivity of 5.2x10 -6 refractive index units was obtained from signal responses to different concentrations of NaCl solutions flowing through the pores. Finally, after functionalizing the alumina pore surfaces with an epoxysilane and then spotting it with β-Lactoglobulin protein, the interactions bet…

AnalyteMaterials scienceNacl solutionsAlumina membranesAnalytical chemistryfood and beveragesSmall sampleRabbit (nuclear engineering)02 engineering and technology021001 nanoscience & nanotechnology01 natural sciences010309 opticsMembrane0103 physical sciences0210 nano-technologyBiosensorRefractive indexSPIE Proceedings
researchProduct

Highly Sensitive Detection of Naphthalene in Solvent Vapor Using a Functionalized PBG Refractive Index Sensor

2012

We report an optical refractive index sensor system based on a planar Bragg grating which is functionalized by substituted γ-cyclodextrin to determine low concentrations of naphthalene in solvent vapor. The sensor system exhibits a quasi-instantaneous shift of the Bragg wavelength and is therefore capable for online detection. The overall shift of the Bragg wavelength reveals a linear relationship to the analyte concentration with a gradient of 12.5 ± 1.5 pm/ppm. Due to the spectral resolution and repeatability of the interrogation system, this corresponds to acquisition steps of 80 ppb. Taking into account the experimentally detected signal noise a minimum detection limit of 0.48 ± 0.05 pp…

AnalyteMaterials sciencegas detection; optical sensor; Bragg grating; cyclodextrin; aromatic hydrocarbonsTransducersaromatic hydrocarbonsAnalytical chemistryPhysics::OpticsNaphthaleneslcsh:Chemical technologyBiochemistryNoise (electronics)gas detectionArticleAnalytical ChemistryFiber Bragg gratinglcsh:TP1-1185Electrical and Electronic Engineeringoptical sensorInstrumentationDetection limitCyclodextrinsEquipment DesignAtomic and Molecular Physics and OpticsEquipment Failure AnalysisRefractometryWavelengthTransducercyclodextrinSolventsBragg gratingGasesRefractometryRefractive indexSensors
researchProduct

Central corneal thickness in mucopolysaccharidosis II and VI.

2010

Objective To describe the ultrasonographically detected central corneal thickness (CCT) in patients with Type II and VI mucopolysaccharidosis (MPS) and its impact on applanation tonometry and glaucoma detection. Methods Twenty-eight patients with MPS (19 MPS II, nine MPS VI) underwent pachymetric investigation of CCT. Additionally, ultrasound measurements of axial length of the globe, slit-lamp evaluation with semiquantitative grading of corneal clouding, applanation tonometry, and assessment of refractive error were performed. Results Median average corneal thickness was 534.5 microm (range, 491.5-579.0 microm) in the MPS II and 547.0 microm (range, 492.5-693.05 microm) in the MPS VI group…

Applanation tonometryAdultMalecongenital hereditary and neonatal diseases and abnormalitiesRefractive errorIntraocular pressuremedicine.medical_specialtygenetic structuresAdolescentMucopolysaccharidosis IIMucopolysaccharidosisGlaucomaCorneal DiseasesCorneaTonometry OcularOphthalmologymedicineHumansIn patientProspective StudiesChildIntraocular PressureMucopolysaccharidosis IIUltrasonographyMucopolysaccharidosis VIAnthropometrybusiness.industryUltrasoundnutritional and metabolic diseasesGlaucomaMiddle Agedmedicine.diseaseeye diseasesOphthalmologyFemalesense organsbusinessCornea
researchProduct