Search results for "Repair"
showing 10 items of 747 documents
Transvaginal rectocele repair reinforced with biological mesh - a video vignette.
2021
Minimally invasive mitral valve surgery: State-of-the-art and our experience
2015
The minimally invasive approach is becoming the standard-of-care for surgery of the mitral valve. As any less invasive strategy, it entails an increased surgical complexity. Standard-of-care mitral repair using the totally videoscopic approach is indeed reproducible; however, few specific data on patients with complex mitral valve disease are available in the published literature. The purpose of the present paper is to provide an overview of the current state-of-the-art in minimally invasive cardiac surgery, and a summary of recent evidence on the topic, with particular regard to the surgical techniques and comparisons with conventional surgery. The experience of the GVM Care and Research n…
Einfluss von Typ-II-Endoleaks auf die Größenänderung und Hämodynamik experimenteller Aortenaneurysmen nach endovaskulärer Therapie
2003
PURPOSE To evaluate the aneurysm volume and the intra-aneurysmatic pressure and maximal pressure pulse (dp/dtmax) in completely excluded aneurysms and cases with endoleaks. MATERIALS AND METHODS In 36 mongrel dogs, experimental autologous aneurysms were treated with stent-grafts. All aortic side branches were ligated in 18 cases (group I) but were preserved in group II (n = 18). Aneurysm volumes were calculated from CT scans before and after intervention, and from follow-up CT scans at 1 week, 6 weeks and 6 months. Finally, for hemodynamic measurements, manometer-tipped catheters were introduced into the excluded aneurysm sac (group I and II), selectively in endoleaks (group II), and intral…
Aulogous fibrin sealant (Vivostat(®)) in the neurosurgical practice: Part II: Vertebro-spinal procedures.
2015
Background Epidural hematomas, cerebrospinal fluid fistula, and spinal infections are challenging postoperative complications following vertebro-spinal procedures. We report our preliminary results using autologous fibrin sealant as both fibrin glue and a hemostatic during these operations. Methods Prospectively, between January 2013 and March 2015, 68 patients received an autologous fibrin sealant prepared with the Vivostat(®) system applied epidurally to provide hemostasis and to seal the dura. The surgical technique, time to bleeding control, and associated complications were recorded. Results Spinal procedures were performed in 68 patients utilizing autologous fibrin glue/Vivostat(®) to…
Case report of a large cephalic vein aneurysm inducing heart failure in a renal transplant patient with radio-cephalic fistula for haemodialysis
2020
Highlights • The venous aneurysm is one of the most common complications of autologous AVF. • The vein aneurysm should be treat by surgical resection and anastomotic ligature. • AVF shouldn’t be ligated from 1-year kidney transplantation except in some cases. • Surgical ligation to prevent complications could be considered an option.
Transcatheter Mitral Repair for Functional Mitral Regurgitation According to Left Ventricular Function: A Real-Life Propensity-Score Matched Study
2020
Background: Transcatheter mitral valve repair (TMVR) could improve survival in functional mitral regurgitation (FMR), but it is necessary to consider the influence of left ventricular ejection fraction (LVEF). Therefore, we compare the outcomes after TMVR with Mitraclip®
Impact of Proportionality of Secondary Mitral Regurgitation on Outcome After Transcatheter Mitral Valve Repair
2020
The purpose of this paper was to evaluate the impact of proportionality of secondary mitral regurgitation (SMR) in a large real-world registry of transcatheter edge-to-edge mitral valve repair (TMVr) BACKGROUND: Differences in the outcomes of recent randomized trials of TMVr for SMR may be explained by the proportionality of SMR severity to left ventricular (LV) volume.The ratio of pre-procedural effective regurgitant orifice area (EROA) to LV end-diastolic volume (LVEDV) was retrospectively assessed in patients undergoing TMVr for severe SMR between 2008 and 2019 from the EuroSMR registry. A recently proposed SMR proportionality scheme was adapted to stratify patients according to EROA/LVE…
Inguinal hernia repair in German military hospitals.
2005
ABSTRACT The inguinal hernia repair continues to be the most common operation in general surgery. Discussing the latest scientific findings, we have prepared this article to present a state-of-the-art approach to the inguinal hernia repair. This approach is used for discussing the general principles of hernia repair in German military hospitals. Quality assurance requires that all hernias be classified during surgery on the basis of a standardized approach for an objective comparison of treatment and outcomes. Our approach to hernia repair considers the age of the patient, the diameter and location of the hernia and whether or not the herniation is recurrent. The Shouldice technique perform…
Association of transcatheter direct mitral annuloplasty with acute anatomic, haemodynamic, and clinical outcomes in severe mitral valve regurgitation.
2020
Abstract Aims Several approaches for transcatheter mitral valve repair for functional mitral valve regurgitation are established. Interventional direct annuloplasty is a novel trans‐venous, trans‐septal approach. While feasibility was proven recently, knowledge on its influence on cardiac dimensions, pressures, biomarkers, and clinical outcomes is sparse. Methods and results Patients consecutively treated with direct annuloplasty‐only procedures between December 2015 and April 2018 were included in this monocentric analysis. Echocardiographic measurements, biomarker levels, clinical status [New York Heart Association (NYHA) class and 6 min walk test] were assessed at baseline, at discharge,…
TEVAR and periscope graft technique to treatment of huge aneurysm of aortic isthmus: Case report
2021
Introduction Thoracic endovascular aortic repair (TEVAR) has revolutionized the treatment of thoracic aortic aneurysms. Innovative techniques as chimney and periscope grafts can improve the outcomes of procedure. Herein, we report a case in emergency of huge Thoracic aortic aneurism. Presentation of case An 86-year-old male with hypertension, diabetes mellitus, was referred to our hospital for chest pain. CT-angiography showed a huge aneurysm of aortic isthmus with signs of rupture. The patient was considered unfit for open surgery and an endovascular approach was chosen. This patient underwent endovascular repair with TEVAR, using the periscope graft technique to preserve patency in left s…