SU-E-T-218: Octavius 4D: Commissioning and Clinical Implementation of a New Device for VMAT Verifications
2013
Purpose: To commission a new device for pre‐treatment patient specific verification of VMAT plans, which is capable of reconstructing 3D dose with high resolution. Methods: Octavius 4D system (PTW) consists of an ion chamber array embedded in a cylindrical phantom which, assisted by an inclinometer, rotates synchronously with the gantry. For VMAT plans, it measures planar dose distributions as a function of gantry angle in order to compute the resulting 3D dose distribution. There are two options for the ion chamber array: Octavius 729 (general purpose) and Octavius 1000 SRS (small field size, high resolution). We have used three linacs: two Varian Clinac iX and one TrueBeam with MLC HD 120…
X-ray spectroscopy and dosimetry with a portable CdTe device.
2007
Abstract X-ray spectra and dosimetry information are very important for quality assurance (QA) and quality control (QC) in medical diagnostic X-ray systems. An accurate knowledge of the diagnostic X-ray spectra would improve the patient dose optimization, without compromising image information. In this work, we performed direct diagnostic X-ray spectra measurements with a portable device, based on a CdTe solid-state detector. The portable device is able to directly measure X-ray spectra at high photon fluence rates, as typical of clinical radiography. We investigated on the spectral performances of the system in the mammographic energy range (up to ∼40 keV). Good system response to monoener…
Repeatability of whole-cornea measurements using a new swept-source optical coherence tomographer
2020
Purpose: The aim of this study was to evaluate the repeatability of several corneal parameters provided by a high-resolution swept-source optical coherence tomographer (SS-OCT). Methods: One eye from each of 74 patients was measured five times consequently using the ANTERION SS-OCT. The following corneal parameters were analyzed: average, steep and flat keratometry (K), astigmatism for anterior, posterior and total at 3-mm, average K and astigmatism at 6-mm, anterior and posterior eccentricity, higher-order aberrations (HOA) and spherical aberration ([Formula: see text]), and anterior and posterior best-fit sphere at 8-mm. The intrasubject standard deviation (Sw), coefficient of variation (…
In vivo methods for drug absorption - comparative physiologies, model selection, correlations with in vitro methods (IVIVC), and applications for for…
2013
This review summarizes the current knowledge on anatomy and physiology of the human gastrointestinal tract in comparison with that of common laboratory animals (dog, pig, rat and mouse) with emphasis on in vivo methods for testing and prediction of oral dosage form performance. A wide range of factors and methods are considered in addition, such as imaging methods, perfusion models, models for predicting segmental/regional absorption, in vitro in vivo correlations as well as models to investigate the effects of excipients and the role of food on drug absorption. One goal of the authors was to clearly identify the gaps in today's knowledge in order to stimulate further work on refining the e…
On the zopiclone enantioselective binding to human albumin and plasma proteins. An electrokinetic chromatography approach
2011
In this work, a methodology for the chiral separation of zopiclone (ZPC) by electrokinetic chromatography (EKC) using carboxymethylated-β-cyclodextrin as chiral selector has been developed and applied to the evaluation of the enantioselective binding of ZPC enantiomers to HSA and total plasma proteins. Two mathematical approaches were used to estimate protein binding (PB), affinity constants (K(1)) and enantioselectivity (ES) for both enantiomers of ZPC. Contradictory results in the literature, mainly related to plasma protein binding reported data, suggest that this is an unresolved matter and that more information is needed. Discrepancies and coincidences with previous data are highlighte…
TRIC: an automated alignment strategy for reproducible protein quantification in targeted proteomics
2016
Nature Methods, 13 (9)
Superresolved imaging of remote moving targets.
2006
We present a superresolving approach that allows one to exceed the diffraction limit and recover highly resolved contours of moving targets from a sequence of low-resolution images. The presented approach is suitable for remote sensing applications. The resolution decoding algorithm that is used to recover the high-resolution features of the target can be run partially via optical means and that way can be used to reduce the required computational complexity.
Optical Characterization Method for Tilted or Decentered Intraocular Lenses
2016
Purpose To test and validate a method for measuring the optical quality and optical power of monofocal intraocular lenses (IOLs) in the presence of a tilt or a decentration as well as its optical power. Methods The experimental system consists of an artificial eye (wet-cell) and a commercial aberrometer with a Shack-Hartmann sensor. Optical image quality parameters such as point spread function (PSF), modulation transfer function (MTF), and the simulations of the retinal image of an extended object are computed from the in vitro wavefront data of an IOL. Repeatability and reproducibility of the system are tested. Mathematical and ray-tracing simulations are used to ascertain the precision a…
Contribution of Taq polymerase-induced errors to the estimation of RNA virus diversity.
1998
The genetic diversity of a vesicular stomatitis virus population was analysed by RT-PCR, cloning and sequencing of two approximately 500 nucleotide regions of the virus genome. PCR amplifications were performed in parallel experiments with both Taq and Pfu DNA polymerases, and important differences were observed. Between 10 and 22 mutations were detected when virus populations were analysed by Taq amplification (20 clones from each region), whereas amplification of the same samples with Pfu revealed between 0 and 5 mutations. PCR fidelity assays, performed under the same PCR conditions as those used in the population analysis, showed that the Taq error-rate estimate of 0.27 x 10(-4) misinco…
Quality of information about oral cancer in Brazilian Portuguese available on Google, Youtube, and Instagram
2020
Background To evaluate the quality of oral cancer information in Brazilian Portuguese on Google, YouTube, and Instagram. Material and Methods The first 100 links of each platform characterized the initial sample. The websites and Instagram were evaluated using the JAMA benchmarks, the Discern instrument, and the Flesch readability index (Flesch Reading Ease). The existence of Health on the Net (HON) code was also registered on websites. The usefulness of each video on YouTube was classified as not useful, slightly useful, moderately useful, or very useful. Results Thirty-four websites, 39 Instagram posts, and 57 videos were evaluated, of which 18 (33.3%) websites and 19 (48.7%) Instagram po…