Search results for "Reproducibility"

showing 10 items of 1976 documents

The Urticaria Activity Score-Validity, Reliability, and Responsiveness.

2018

Background Chronic spontaneous urticaria is characterized by fluctuating symptoms. Its activity is assessed with the urticaria activity score (UAS). Two versions of the urticaria activity score used for 7 consecutive days (UAS7) are available: (1) The guideline-recommended UAS7, with once-daily documentation, and (2) the UAS7TD, with twice-daily documentation. Objective To better characterize both UAS7 versions with regard to their validity, reliability, sensitivity to change, minimal important difference (MID), and smallest detectable change (SDC). Methods One hundred thirty adult patients with chronic spontaneous urticaria completed both UAS7 versions, the Patients Global Assessment (PatG…

AdultMalemedicine.medical_specialtyUrticariaIntraclass correlationOmalizumabOmalizumabSeverity of Illness IndexDisease activity030207 dermatology & venereal diseases03 medical and health sciences0302 clinical medicineQuality of lifeimmune system diseasesInternal medicineAnti-Allergic AgentsImmunology and AllergyMedicineHumansskin and connective tissue diseasesReceiver operating characteristicbusiness.industryReproducibility of ResultsDermatology Life Quality IndexMiddle AgedStandard error030228 respiratory systemChronic DiseasePhysical therapyPatient-reported outcomeFemalebusinessmedicine.drugThe journal of allergy and clinical immunology. In practice
researchProduct

Liver assessment and biopsy in patients with marked coagulopathy: value of mini-laparoscopy and control of bleeding.

2003

Evaluation of liver disease in patients with a high risk of postbiopsy bleeding presents a diagnostic challenge. Mini-laparoscopy offers the possibility of coagulation of biopsy site and the additional advantage of macroscopic liver assessment. We wished to assess the value and safety of mini-laparoscopy with guided biopsy as a diagnostic approach in patients in whom percutaneous liver biopsy is considered contraindicated because of a marked coagulopathy.We investigated 61 consecutive patients with marked coagulopathy (prolonged international normalized ratio1.5, thrombocytopenia50/nl, or both; von Willebrand's disease/hemophilia). Diagnostic mini-laparoscopy with visually guided liver biop…

AdultMalemedicine.medical_specialtyValidation studyAdolescentBiopsyHemorrhageBiopsymedicineCoagulopathyHumansIn patientLaparoscopyChildBiopsy methodsAgedAged 80 and overHepatologymedicine.diagnostic_testbusiness.industryLiver DiseasesMini laparoscopyGastroenterologyInfantReproducibility of ResultsEquipment DesignBlood Coagulation DisordersMiddle Agedmedicine.diseaseLaparoscopesSurgeryEndoscopyChild PreschoolFeasibility StudiesFemaleLaparoscopyRadiologybusinessThe American journal of gastroenterology
researchProduct

Development, validation, and initial results of the Angioedema Activity Score

2013

Background Recurrent angioedema (RecA) is a frequent clinical problem characterized by suddenly occurring cutaneous and/or mucosal swellings. Depending on their location, RecA may be painful, hindering, disfiguring, or even life-threatening. The assessment of disease activity in affected patients is important to guide treatment decisions. Currently, however, there is no standardized and validated outcome measure available to do so. Objective To develop and validate the first specific patient-reported outcome instrument to assess disease activity in RecA patients, the Angioedema Activity Score (AAS). Methods After a set of potential AAS items was developed, item evaluation and reduction were…

AdultMalemedicine.medical_specialtyValidation studyAdolescentImmunologyValiditySeverity of Illness IndexYoung AdultRisk FactorsInternal consistencyHumansImmunology and AllergyMedicineAngioedemaReliability (statistics)AgedFace validityAged 80 and overAngioedemabusiness.industryReproducibility of ResultsRegression analysisMiddle AgedConvergent validityPhysical therapyFemalemedicine.symptombusinessAllergy
researchProduct

Nitrate-induced coronary vasodilation by stress-magnetic resonance imaging: A novel noninvasive test of coronary vasomotion

2004

Purpose To evaluate the feasibility of assessing coronary vasodilation following exogenous nitrates, using magnetic resonance angiography (MRA). The assessment of coronary response to exogenous nitrovasodilators may have a diagnostic and prognostic impact in patients with coronary artery disease. To date, stress imaging of coronary artery vasomotion has been confined to the catheterization laboratory. MRA is emerging as a noninvasive tool for coronary artery imaging. Materials and Methods Coronary MRA was performed in 20 healthy volunteers (12 males, age = 33 ± 8). We used spiral spoiled gradient echo (SSGE) sequences for imaging of coronary artery lumen. After the baseline short-axis view …

AdultMalemedicine.medical_specialtyVasodilator AgentsLumen (anatomy)VasodilationVasomotionStatistics NonparametricMagnetic resonance angiographyCoronary artery diseaseNitroglycerinInternal medicinemedicine.arterymedicineHumansRadiology Nuclear Medicine and imagingmedicine.diagnostic_testbusiness.industryReproducibility of ResultsMagnetic resonance imagingmedicine.diseaseCoronary Vesselsmedicine.anatomical_structureRight coronary arteryCardiologyFeasibility StudiesFemalebusinessMagnetic Resonance AngiographyArteryJournal of Magnetic Resonance Imaging
researchProduct

Comparison of two different labial salivary gland biopsy incision techniques: A randomized clinical trial

2013

Objectives: To compare the reliability of two different labial salivary gland biopsy (LSGB) incision techniques (vertical versus horizontal incision techniques) and to report the related complications and discomfort. Study Design: 163 patients who underwent LSGB were included in this study. Patients were randomly divided as vertical incision group (n=81) and horizontal incision group (n=82). Demographic and clinical information of each patient were recorded. A questionnaire was prepared and applied together with Visual Analog Scale (VAS) on the subjects verbally at the 7th day, postoperatively. Intraoperative, short- term and delayed complications were evaluated. Results: The mean age of pa…

AdultMalemedicine.medical_specialtyVisual analogue scaleBiopsyOdontologíaSalivary Glands Minorlaw.inventionYoung AdultHematomaPostoperative ComplicationsRandomized controlled triallawSurveys and QuestionnairesBiopsymedicineHumansProspective StudiesProspective cohort studyGeneral DentistryAgedBiopsy incisionmedicine.diagnostic_testbusiness.industryReproducibility of ResultsMiddle Aged:CIENCIAS MÉDICAS [UNESCO]medicine.diseaseCiencias de la saludLipSurgeryLabial salivary glandOtorhinolaryngologyUNESCO::CIENCIAS MÉDICASSurgeryResearch-ArticleFemaleOral SurgerybusinessComplicationMedicina Oral, Patología Oral y Cirugía Bucal
researchProduct

Computerized acoustic voice analysis and subjective scaled evaluation of the voice can avoid the need for laryngoscopy after thyroid surgery.

2008

Because of frequent postoperative alterations in voice, many surgeons include laryngoscopy as a routine examination before/after thyroid surgery. The aim of this work was to determine whether more comfortable and easier subjective or objective postoperative voice assessments could complement or replace laryngoscopy.Sixty-four consecutive patients scheduled to undergo thyroid surgery underwent preoperative objective computerized acoustic voice analysis (CAVA), subjective scaled evaluation of the voice (SSEV) with the GIRBAS scale, and fiberoptic laryngoscopy. All patients had 7- and 30-day postoperative follow-up assessments using the same tests.CAVA measurements of jitter and noise-to-harmo…

AdultMalemedicine.medical_specialtyVoice QualityLaryngoscopyAcoustic voice analysisSpeech Production MeasurementmedicineHumansDiagnosis Computer-AssistedProspective StudiesVocal Cord PalsyAgedAged 80 and overVoice Disordersmedicine.diagnostic_testLaryngoscopybusiness.industryThyroidReproducibility of ResultsAcousticsMiddle AgedEndoscopySurgerymedicine.anatomical_structureAnesthesiaThyroidectomySurgeryFemalebusinessFiberoptic laryngoscopyVocal Cord ParalysisSurgery
researchProduct

Body Composition and Fitness during Strength and/or Endurance Training in Older Men

2008

PURPOSE: This study examined adaptations in body composition and physical fitness during a 21-wk strength and/or endurance training period in 40- to 65-yr-old men. We also compared the usefulness of different methods for the analysis of body composition to detect training-induced adaptations. METHODS: Fifty-three men were randomized into the endurance training (E: N = 14), strength training (S: N = 13), combined strength and endurance training (SE: N = 15), or control (C: N = 11) groups. S and E trained 2 and SE 2 x 2 times a week for strength and endurance. RESULTS: Percentage of fat (fat%) decreased (5-8%) similarly in all training groups. Fat% measured by DXA at baseline and its change c…

AdultMalemedicine.medical_specialtyWaistStrength trainingPhysical fitnessPhysical Therapy Sports Therapy and RehabilitationAbsorptiometry PhotonOxygen ConsumptionAnimal scienceEndurance trainingElectric ImpedanceHumansMedicineOrthopedics and Sports MedicineAgedAnalysis of VariancePhysical Education and Trainingbusiness.industryReproducibility of ResultsVO2 maxMiddle AgedAdaptation PhysiologicalWaistlinePhysical FitnessBody CompositionExercise TestPhysical EndurancePhysical therapyLean body massAnalysis of variancebusinessMedicine & Science in Sports & Exercise
researchProduct

Design and validation of a patient-reported outcome measure scale in acute pancreatitis: the PAN-PROMISE study

2021

ObjectiveThis study aimed to develop and validate a patient-reported outcome measure (PROM) in acute pancreatitis (AP) as an endpoint centred on the patient.DesignA PROM instrument (PAtieNt-rePoRted OutcoMe scale in acute pancreatItis, an international proSpEctive cohort study, PAN-PROMISE scale) was designed based on the opinion of patients, professionals and an expert panel. The scale was validated in an international multicentre prospective cohort study, describing the severity of AP and quality of life at 15 days after discharge as the main variables for validation. The COSMIN (COnsensus-based Standards for the selection of health status Measurement INstruments) methodology was applied.…

AdultMalemedicine.medical_specialtyacute pancreatitisOrdinal ScalePromCohort Studies03 medical and health sciences0302 clinical medicinePredictive Value of TestsCriterion validitymedicineHumansPatient Reported Outcome Measures030212 general & internal medicineProspective cohort studyReliability (statistics)AgedFace validityHospital Prof. Dr. Fernando Fonseca E.P.E.business.industryGastroenterologyReproducibility of ResultsPAN-PROMISE study.Middle AgedHospitalizationClinical trialClinical trialPancreatitisQuality of LifePhysical therapyFemale030211 gastroenterology & hepatologyPatient-reported outcomeSymptom AssessmentbusinessGut
researchProduct

Clinical evaluation of a wireless ECG sensor system for arrhythmia diagnostic purposes

2013

Accepted version of an article in the journal: Medical Engineering and Physics. Also available from the publisher at: http://dx.doi.org/10.1016/j.medengphy.2013.03.002 In a clinical study, a novel wireless electrocardiogram (ECG) recorder has been evaluated with regard to its ability to perform arrhythmia diagnostics. As the ECG recorder will detect a "non-standard" ECG signal, it has been necessary to compare those signals to "standard" ECG recording signals in order to evaluate the arrhythmia detection ability of the new system. Simultaneous recording of ECG signals from both the new wireless ECG recorder and a conventional Holter recorder was compared by two independent cardiology specia…

AdultMalemedicine.medical_specialtyambulatory electrocardiographyBiomedical EngineeringBiophysicsElectrocardiographyYoung Adultevaluation studiesmedicineHumansWirelessMedical physicscardiovascular diseasesChildReference standardsAgedAmbulatory electrocardiographySensor systemclinical trialsbusiness.industryReproducibility of ResultsArrhythmias CardiacSignal Processing Computer-AssistedVDP::Technology: 500::Information and communication technology: 550Middle AgedReference StandardsHolter monitoringClinical trialVDP::Medical disciplines: 700wireless ECG sensorFemalebusinessTelecommunicationsWireless TechnologyClinical evaluationHolter monitoring
researchProduct

Two-dimensional echocardiographic evaluation of left ventricular ejection fraction by the ellipsoid single-plane algorithm: a reliable method for ass…

1995

The reliability of two-dimensional (2D) echocardiographic estimation of left ventricular ejection fraction (EF) is commonly recognized, but no satisfactory data are available about the accuracy of low or very low EF values determined by 2D echocardiography (ECHO-EF). The purpose of our study was to assess the reliability of low ECHO-EF values obtained using a simple time-economical algorithm such as the ellipsoid single-plane area-length method. Radionuclide angiography (RAD-EF) was taken as the standard of comparison. We studied 59 consecutive patients (31 women and 28 men) referred to our echocardiographic laboratory. Both 2D echocardiography and radionuclide angiography were blindly perf…

AdultMalemedicine.medical_specialtyanimal structuresSettore MED/09 - Medicina InternaCardiac Output LowVentricular Function LeftVentricular Dysfunction LeftRadionuclide angiographyVentricule gaucheReference ValuesInternal medicinemedicineHumansPharmacology (medical)AgedEjection fractionmedicine.diagnostic_testPlane (geometry)business.industryTwo dimensional echocardiographyReproducibility of ResultsGated Blood-Pool ImagingSignal Processing Computer-AssistedStroke VolumeMiddle AgedEllipsoidSettore MED/11 - Malattie Dell'Apparato CardiovascolareArea length methodTwo dimensional echocardiography Area-lenght method Radionuclide angiography Ejection fraction Regression analysisEchocardiographyCardiologyFemaleCardiology and Cardiovascular MedicinebusinessNuclear medicineAlgorithms
researchProduct