Search results for "Reproducibility"

showing 10 items of 1976 documents

ProC Global: the first functional screening assay for the complete protein C pathway.

1997

Abstract In clinical practice, venous thromboembolic complications are much more frequent than bleeding disorders. In fact, disturbances within the protein C pathway due to coagulation factor V (FV) Leiden mutation and deficiency of protein C or protein S are the most frequent abnormalities in hereditary thrombophilia. Furthermore, acquired dysfunctions of the protein C system may predispose the single individual to an increased thrombotic risk. A routine-suited screening assay that would allow the monitoring of the proper interplay of factors in the protein C pathway could add an important factor to the basic coagulation profile. This consists of the prothrombin time and of the activated p…

Clinical BiochemistryBlood DonorsSensitivity and SpecificityProtein SProtein SProtein C deficiencyReference ValuesMedicineHumansMass ScreeningProtein S deficiencyProthrombin timemedicine.diagnostic_testbiologybusiness.industryBiochemistry (medical)Factor VFactor VProtein C DeficiencyReproducibility of ResultsThrombosisBlood Coagulation Disordersmedicine.diseaseImmunologyMutationbiology.proteinCancer researchPartial Thromboplastin TimeDisease SusceptibilityReagent Kits DiagnosticActivated protein C resistancebusinessProtein CPartial thromboplastin timemedicine.drugProtein CClinical chemistry
researchProduct

The application of phospholipid removal columns and ultra-high performance liquid chromatography-tandem quadrupole mass spectrometry for quantificati…

2016

In this study a robust and sensitive method based on a proposed sample purification procedure, using zirconia-coated Phree™ columns and analysis by ultra-high performance liquid chromatography with triple quadrupole tandem mass spectrometry are presented for the assessment of multi-class antibiotics in farmed fish species. The sample preparation procedure benefited from combined precipitation of proteins and selective removal of phospholipids by Phree™ columns, resulting in a high sensitivity of the method (LOQ 0.3-9mgkg(-1)). The in-house validation results (precision, repeatability, decision limit CCα, detection capability CCβ, etc.) indicate that the elaborated method is fully suitable f…

Clinical BiochemistryPharmaceutical ScienceAquacultureTandem mass spectrometryMass spectrometry01 natural sciencesTrimethoprimAnalytical ChemistryTandem Mass SpectrometryDrug DiscoveryEnrofloxacinmedicinemedia_common.cataloged_instanceAnimalsSample preparationEuropean unionSpectroscopyChromatography High Pressure LiquidPhospholipidsmedia_commonEnrofloxacinChromatographyTandem010405 organic chemistryChemistry010401 analytical chemistryFishesReproducibility of ResultsRepeatabilityDrug Residues0104 chemical sciencesTriple quadrupole mass spectrometerAnti-Bacterial Agentsmedicine.drugFluoroquinolonesJournal of pharmaceutical and biomedical analysis
researchProduct

In situ generation of Co(II) by use of a solid-phase reactor in an FIA assembly for the spectrophotometric determination of penicillamine

2005

[EN] A flow injection analysis (FIA) manifold for the determination of penicillamine in pharmaceutical preparations is proposed. The manifold includes a solid-phase reactor for the in situ production of the derivatizing reagent, Co(II) ion, which forms a coloured complex with penicillamine in an alkaline medium. The reactor is prepared by natural immobilization of cobalt carbonate on a polymer matrix, which endows it with a high mechanical and microbiological stability. The cobalt released by passage of a 5 x 10(-4) Mol l(-1) sulphuric acid stream at a flow-rate of 2.3 ml min(-1) is merged with a volume of 314 mu l of sample containing penicillamine in ammonium-ammonia buffer at pH 9.5 to m…

Clinical BiochemistryPharmaceutical Sciencechemistry.chemical_elementAnalytical ChemistryMatrix (chemical analysis)AbsorbanceFIAFlow injection analysisSpectrophotometryDrug DiscoveryQUIMICA ANALITICAmedicineSpectroscopyFlow injection analysisDetection limitChromatographymedicine.diagnostic_testChemistrySpectrum AnalysisPenicillaminePenicillamineReproducibility of ResultsCobaltSolid-phase reactorReagentPharmaceuticalsCobaltmedicine.drug
researchProduct

Evaluation of enantioselective binding of fluoxetine to human serum albumin by ultrafiltration and CE - Experimental design and quality considerations

2012

Several pharmacokinetic processes are affected by enantioselectivity (ES). At the level of distribution, protein binding (PB) is one of the most important. The enantioselective binding of fluoxetine (FLX) to HSA has been evaluated in this work by ultrafiltration of FLX–HSA mixtures and chiral analysis of unbound fractions by EKC-CD. PB, affinity constants (K) and ES were obtained for both enantiomers of FLX. In order to improve the consistency of the estimations, the evaluation of affinity constants of each enantiomer was performed using two designs, one keeping constant the total concentration of protein and varying the total concentration of the enantiomers, and the other in the opposite …

Clinical BiochemistrySerum albuminUltrafiltrationUltrafiltrationStereoisomerismBiochemistryAnalytical ChemistryFluoxetinemedicineHumansBinding siteSerum AlbuminChromatographybiologyChemistryEnantioselective synthesisElectrophoresis CapillaryReproducibility of ResultsStereoisomerismHuman serum albuminModel validityNonlinear Dynamicsbiology.proteinEnantiomerAlgorithmsProtein Bindingmedicine.drugELECTROPHORESIS
researchProduct

Evaluation of enantioselective binding of propanocaine to human serum albumin by ultrafiltration and electrokinetic chromatography under intermediate…

2011

Abstract Stereoselectivity in protein binding can have a significant effect on the pharmacokinetic and pharmacodynamic properties of chiral drugs. In this paper, the enantioselective binding of propanocaine (PRO) enantiomers to human serum albumin (HSA), the most relevant plasmatic protein in view of stereoselectivity, has been evaluated by incubation and ultrafiltration of racemic PRO–HSA mixtures and chiral analysis of the bound and unbound fractions by electrokinetic chromatography using HSA as chiral selector. Experimental conditions for the separation of PRO enantiomers using HSA as chiral selector and electrokinetic chromatography have been optimised. Affinity constants and protein bi…

Clinical BiochemistryUltrafiltrationUltrafiltrationPlasma protein bindingBiochemistryBenzoatesAnalytical ChemistryIn vivomedicineHumansSerum AlbuminChromatography Micellar Electrokinetic CapillaryChromatographyPropylaminesElutionChemistryEnantioselective synthesisReproducibility of ResultsStereoisomerismCell BiologyGeneral MedicineHydrogen-Ion ConcentrationHuman serum albuminLinear ModelsStereoselectivityEnantiomermedicine.drugProtein BindingJournal of chromatography. B, Analytical technologies in the biomedical and life sciences
researchProduct

Realization of administration unit for3He with gas recycling

2011

Hyperpolarized (HP) noble gases (3He,129Xe) are used for MR-imaging of the lung. In the majority of case the HP gas is filled in Tedlarbags and directly inhaled by the patients. Starting from an earlier pilot device, an administration unit was built respectively to the Medical Devices Law to administer patients HP noble gas boli in defined quantities and at a predefined time during inspiration with high reproducibility and reliability without reducing MR-quality. The patient's airflows are monitored and recorded. It is possible to use gas admixtures, measure the polarization on-line and collect the exhaled gas for later recycling. The first images with healthy volunteers were taken with thi…

Clinical studyHistoryReproducibilitybusiness.industryHealthy volunteersNoble gasMedicinebusinessComputer Science ApplicationsEducationBiomedical engineeringJournal of Physics: Conference Series
researchProduct

Multicenter stability of diffusion tensor imaging measures: a European clinical and physical phantom study.

2011

Diffusion tensor imaging (DTI) detects white matter damage in neuro-psychiatric disorders, but data on reliability of DTI measures across more than two scanners are still missing. In this study we assessed multicenter reproducibility of DTI acquisitions based on a physical phantom as well as brain scans across 16 scanners. In addition, we performed DTI scans in a group of 26 patients with clinically probable Alzheimer's disease (AD) and 12 healthy elderly controls at one single center. We determined the variability of fractional anisotropy (FA) measures using manually placed regions of interest as well as automated tract based spatial statistics and deformation based analysis. The coefficie…

Coefficient of variationNeuroscience (miscellaneous)Nerve Fibers MyelinatedBrain mappingImaging phantommethods [Diffusion Tensor Imaging]White matterYoung AdultNeuroimagingBiasAlzheimer Diseasepathology [Brain]Fractional anisotropymedicineHumansRadiology Nuclear Medicine and imagingddc:610AgedAged 80 and overReproducibilityBrain Mappingpathology [Nerve Fibers Myelinated]business.industryPhantoms Imagingdiagnosis [Alzheimer Disease]BrainMiddle AgedEuropePsychiatry and Mental healthDiffusion Tensor Imagingmedicine.anatomical_structureAnisotropyFemaleNuclear medicinebusinessPsychologyDiffusion MRI
researchProduct

Smart Phone, Smart Science: How the Use of Smartphones Can Revolutionize Research in Cognitive Science

2011

WOS:000295936900019; International audience; Investigating human cognitive faculties such as language, attention, and memory most often relies on testing small and homogeneous groups of volunteers coming to research facilities where they are asked to participate in behavioral experiments. We show that this limitation and sampling bias can be overcome by using smartphone technology to collect data in cognitive science experiments from thousands of subjects from all over the world. This mass coordinated use of smartphones creates a novel and powerful scientific "instrument" that yields the data necessary to test universal theories of cognition. This increase in power represents a potential re…

Cognitive scienceSocial and Behavioral SciencesPsycholinguistics[SCCO]Cognitive scienceCognitionEngineering0302 clinical medicineSoftwareSoftware DesignPsychologyMedicineAttentionComputingMilieux_MISCELLANEOUSLanguageCognitive scienceFaculty of Science\PsychologyLEXICAL DECISION TASKMultidisciplinaryPsycholinguisticsQ05 social sciencesRExperimental psychologySoftware EngineeringCognitionDIFFUSION-MODEL ACCOUNTExperimental economicsTest (assessment)SemanticsResearch facilitiesMental HealthComputers Handheld[SCCO.PSYC]Cognitive science/PsychologyMedicineInformation TechnologyResearch ArticleExperimental psychologyScienceCognitive NeuroscienceCell phonesSemantics050105 experimental psychologyDatabases03 medical and health sciencesMemoryHumans0501 psychology and cognitive sciencesChemistry (relationship)BiologyBehaviorbusiness.industryResearchCognitive PsychologyBiology and Life SciencesReproducibility of ResultsComputer ScienceAttention (Behavior)businessCell PhoneSoftware030217 neurology & neurosurgeryNeuroscience
researchProduct

Effect of inter-crystal scatter on estimation methods for random coincidences and subsequent correction.

2008

Random coincidences can contribute substantially to the background in positron emission tomography (PET). Several estimation methods are being used for correcting them. The goal of this study was to investigate the validity of techniques for random coincidence estimation, with various low-energy thresholds (LETs). Simulated singles list-mode data of the MADPET-II small animal PET scanner were used as input. The simulations have been performed using the GATE simulation toolkit. Several sources with different geometries have been employed. We evaluated the number of random events using three methods: delayed window (DW), singles rate (SR) and time histogram fitting (TH). Since the GATE simula…

CoincidenceCrystalRandom AllocationImaging Three-DimensionalHOT RegionHistogramSmall animalStatisticsImage Processing Computer-AssistedAnimalsScattering RadiationRadiology Nuclear Medicine and imagingMathematicsTomography Emission-Computed Single-PhotonModels StatisticalRadiological and Ultrasound TechnologyComputersCompton scatteringReproducibility of ResultsReconstruction algorithmEquipment DesignModels TheoreticalComputational physicsPositron-Emission TomographyEstimation methodsCrystallizationMonte Carlo MethodSoftwarePhysics in medicine and biology
researchProduct

Isometric endurance test of the cervical flexor muscles - Reliability and normative reference values.

2017

Abstract Objective To obtain reference values for the isometric endurance test (IET) of the cervical flexor muscles, investigate its reproducibility, and compare the results with the maximal isometric strength test (MIST) of the cervical flexor muscles. Design Cross-sectional non-comparative study with single group repeated measurements. Methods Altogether 219 healthy females aged 20–59 years volunteered to participate in the study. The IET was performed in the supine position and MIST seated. The reproducibility was evaluated by the intraclass correlation coefficient (ICC) and an analysis described by Bland and Altman. The relationship between the two measuring methods was evaluated by Pea…

Complementary and Manual TherapyAdultmedicine.medical_specialtySupine positionCorrelation coefficientIntraclass correlationendurance strengthPhysical Therapy Sports Therapy and RehabilitationIsometric exercisenon-specific neck painisometric contraction03 medical and health sciencesDisability EvaluationYoung Adult0302 clinical medicineintrarater reliabilityNeck MusclesReference ValuesIsometric ContractionmedicineHumansMuscle Skeletal030222 orthopedicsReproducibilitybusiness.industryRehabilitationniskakipuReproducibility of Resultsta3141Intra-rater reliabilityRepeatabilityMiddle AgedTrunkCross-Sectional StudiesComplementary and alternative medicinemaximal strengthPhysical therapyFemalebusiness030217 neurology & neurosurgeryJournal of bodywork and movement therapies
researchProduct