Search results for "Resin Cements"
showing 3 items of 23 documents
The effect of dentine pre-treatment using bioglass and/or polyacrylic acid on the interfacial characteristics of resin-modified glass ionomer cements.
2018
Objective To evaluate the effect of load-cycle aging and/or 6 months artificial saliva (AS) storage on bond durability and interfacial ultramorphology of resin-modified glass ionomer cement (RMGIC) applied to dentine air-abraded using Bioglass 45S5 (BAG) with/without polyacrylic acid (PAA) conditioning.Methods RMGIC (Ionolux, VOCO) was applied onto human dentine specimens prepared with silicon-carbide abrasive paper or air-abraded with BAG with or without the use of PAA conditioning. Half of bonded-teeth were submitted to load cycling (150,000 cycles) and half immersed in deionised water for 24 h. They were cut into matchsticks and submitted immediately to microtensile bond strength (μTBS) …
Effect of postbleaching application of an antioxidant on enamel bond strength of three different adhesives
2010
Objectives: The aim of this study was to compare the shear bond strength (sbs) of three different adhesives on bleached enamel immmmediately after bleaching, bleached/delayed for 1 week, and bleached/applied antioxidizing agent. Study Design: The enamel surfaces of 144 freshly extracted incisors without any caries and restorations were flattened and divided into 12 groups. The following adhesives were investigated: Optibond FL (OFL) (three-step etch&rinse), Optibond Solo Plus (OSP) (two-step etch&rinse), Optibond All-in-One (OA) (one-step self-etch), (Kerr, Orange, USASA). Unbleached enamel groups were prepared as negative controls. The remainder surfaces were bleached with 20% Opalescent P…
Effect of thermocycling with or without 1 year of water storage on retentive strengths of luting cements for zirconia crowns
2015
Abstract Statement of problem Bond stability between zirconia crowns and luting cement and between cement and dentin is a main concern; however, only limited evidence is available as to its longevity. Purpose The purpose of this in vitro study was to measure the retentive strengths of 7 self-adhesive cements (RelyX Unicem Aplicap, RelyX Unicem Clicker, RelyX Unicem 2 Automix, iCEM, Maxcem Elite, Bifix SE, SpeedCem), 2 adhesive cements with self-etch primers (Panavia 21, SEcure), 1 glass ionomer cement (Ketac Cem), 1 resin-modified glass ionomer cement (Meron Plus), and 1 zinc phosphate cement for luting zirconia crowns (LAVA) to extracted teeth after thermocycling with or without 1 year of …