Search results for "Resins"
showing 10 items of 176 documents
Long-term sealing ability of GuttaFlow versus Ah Plus using different obturation techniques.
2010
Objective. To compare the long-term sealing ability of GuttaFlow® using different obturation techniques. Study Design. Three hundred teeth, prepared with a crown-down technique, were divided into thirty experimental groups (n=10) to evaluate the apical and coronal leakage, at 3, 30 and 120 days, of lateral compaction gutta-percha + AH Plus?, lateral compaction gutta-percha + GuttaFlow®, single cone + AH Plus?, single cone + GuttaFlow®, and GuttaFlow® only. Results. Both coronal and apical leakage, at the three times of measurement, no significant differences were found among GuttaFlow® + lateral compaction gutta-percha and GuttaFlow® + single cone groups, whereas the only GuttaFlow® reached…
Scandium-44: Benefits of a Long-Lived PET Radionuclide Available from the 44Ti/44Sc Generator System
2011
(44)Ti/(44)Sc radionuclide generators are of interest for molecular imaging. The 3.97 hours half-life of (44)Sc and its high positron branching of 94.27% may stimulate the application of (44)Sc-labeled PET radiopharmaceuticals. This review describes the current status of (44)Ti production, (44)Ti/(44)Sc radionuclide generator development, post-processing of generator eluates towards medical application, identification of ligands adequate to Sc(III) co-ordination chemistry, proof-of-principle labeling of (44)Sc-DOTA-octreotides, investigation of in vitro and in vivo parameters, and initial applications for molecular imaging - both in small animals and humans.
Citotoxicity of four types of resins used for removable denture bases: in vitro comparative analysis
2009
Objective: To compare the cytotoxicity of four types of resins used for manufacturing denture bases. Method and Materials: 9 disk-shaped samples of four resin (two heat-polymerized, one auto-polymerized, and one light-polymerized), 9 samples of glass (negative control) and 9 samples of lead (positive control) were made according to the manufacturer instructions. The materials were tested by contact with BALB/C 3T3 fibroblast cells. Each sample was tested after 24, 48 and 72 hours. The cellular vitality was verified through spectrophotometric analysis of the solution where the colour is directly related to the amount of metabolically active and living cells. The results were analyzed through…
Remineralization effects of conventional and experimental ion-releasing materials in chemically or bacterially-induced dentin caries lesions
2019
Abstract Objectives The aim of this study was to evaluate the remineralization effects of conventional and experimental ion-releasing materials on different artificial dentin carious lesions. Methods Forty human dentin discs were submitted to different demineralization protocols for simulated caries lesion: (D1) Shallow chemically-induced caries, (D2) deep chemically-induced caries, (D3) deep bacterially-induced caries. Each disc was divided in five parts; one of those served as baseline control. The remaining parts of each disc (n = 12–16/group) were treated using the following materials: EXP, an experimental resin-based bioactive material consisting of a self-etch primer and an adhesive c…
A laboratory comparison of Individual Targis/Vectris posts with standard fiberglass posts
2007
This article presents an in vitro analysis of a specific occlusal loading test on endodontically treated teeth restored with 2 different composite post materials. Individual, customized posts (IFPs) were compared to standard fiberglass posts (SFPs). The selected IFPs (standard cylindric Targis/Vectris posts) were compared to SFPs (Conic 6% Post, Ghimas). The posts were first subjected to a 3-point bending test to compare their flexural elastic properties. They were then used to restore 22 endodontically treated artificial maxillary central incisors and subjected to a specific occlusal loading simulation test. The loading test showed that IFP restorations performed better than SFP restoratio…
Reduction of Polymerization Shrinkage Stress and Marginal Microleakage Using Soft-Start Polymerization
2003
Purpose: This study evaluated the influence of a soft-start light-curing exposure on polymerization shrinkage stress and marginal integrity of adhesive restorations. Materials and Methods: Six resin-based composites (Pertac II, Tetric Ceram, Definite, Surefil, Solitaire, and Visio-Molar) were adhesively bonded to a cylindrical cavity (n = 9 per material/light) in a photoelastic material. Visible light-curing was applied using either the standard polymerization mode (800 mW/cm2 exposure duration 40 s) of the curing light (Elipar TriLight, 3M ESPE) or the exponential mode from the same device (ramp-curing: 150 mW/cm2 to 800 mW/cm2 within the first 15 s of a total curing time of 40 s). Polymer…
Xenotransplantation of parathyroids in rats using barium-alginate and polyacrylic acid multilayer microcapsules
2001
The integrity and function of encapsulated parathyroid tissue following xenotransplantation is limited by oxygen and nutrition supply and capsule fibrosis. Since some of these factors depend on stability and biocompatibility of the coating material, multilayer microcapsules have been developed. Parathyroid tissue pieces and digested single cells from pigs were encapsulated in barium-alginate and in polyacrylic acid (PAA) multilayer capsules. After 7 days of culture the function of the encapsulated cells were assessed. Subsequently, in a part of the cultured microcapsules the viability was directly assessed whereas the other part was transplanted in dark animal [DA] rats for 30 days. After e…
Supravital Uptake of Cationic Dyes by Mast Cell Granules: A Light and Electron Microscope Study
1994
Methylene blue and neutral red were selected for staining mast cell granules by supravital injections. A new technique was applied for embedding in paraffin and Araldite without dislocation or loss of dye. Stabilization and electron microscopic identification of the dyes were achieved by transforming them into electron-dense precipitates using phosphomolybdic acid dissolved in a paraformaldehyde-glutaraldehyde mixture to preserve the ultrastructure of the tissues. It was found that in general the intensity of the light microscopic staining correlated directly with the electron density. Closer study revealed that not all cytoplasmic granules exhibited the same strong affinity for the cationi…
Solidification of ion exchange resins saturated with Na+ ions: Comparison of matrices based on Portland and blast furnace slag cement
2017
International audience; Ion exchange resins (IERs) are widely used by the nuclear industry to decontaminate radioactive effluents. After use, they are usually stabilized and solidified by encapsulation in cementitious materials. However, for certain combinations of cement and resins, the solidified waste forms can exhibit strong expansion, possibly leading to cracking of the matrix. In this work, the behaviour of cationic resins in the Na$^+$ form is investigated in Portland cement (CEM I) or blast furnace slag cement (CEM III/C) pastes at early age in order to have a better understanding of the swelling process. The results show that during the hydration of the CEM I paste, the resins exhi…
Cytotoxic effect of silorane and methacrylate based composites on the human dental pulp stem cells and fibroblasts
2014
Objectives: The aim of this study was to compare the cytotoxic effect of a methacrylate-based and a silorane- based composite on the human dental pulp stem cells (DPSCs) versus human dental pulp fibroblasts (DPFs). Study Design: Samples of the Filtek Z250 and P90 were polymerized and immersed in the culture medium to obtain extracts after incubation for one, seven and 14 days. Magnetic cell sorting based on the CD146 expression was performed to purify DPSCs and DPFs. After incubation of both cells with the extracts, cytotoxicity was de - termined using the MTT test. Results: For the extracts of first and seventh day, both composites showed significantly lower cytotoxicity on DPSCs than DPFs…