Search results for "Resins"
showing 10 items of 176 documents
Visual acuity tolerance to residual refractive errors in patients with an apodized diffractive intraocular lens.
2007
To assess visual acuity tolerance to defocus caused by residual refractive errors after clear lens extraction (CLE) with apodized diffractive intraocular lens (IOL) implantation.Fernández-Vega Ophthalmological Institute, Oviedo, Spain.In this prospective study, 150 eyes of 75 consecutive patients who had bilateral CLE with implantation of an AcrySof ReSTOR Natural IOL (Alcon) were evaluated. The eyes were divided into 2 groups: myopia and hyperopia. Residual refractive errors were analyzed using vector analysis. Monocular and binocular uncorrected distance visual acuity, best corrected distance visual acuity, uncorrected distance near visual acuity, and best distance-corrected near visual a…
Foldable toric intraocular lens for astigmatism correction in cataract patients.
2007
PURPOSE: To evaluate the results of AcrySof toric intraocular lens (IOL) (Alcon) implantation to correct preexisting astigmatism in patients having cataract surgery. SETTING: Ophthalmology Service, Donostia Hospital, San Sebastian, Spain. METHODS: This prospective observational study included 30 eyes of 15 consecutive patients with more than 1.00 diopter (D) of preexisting corneal astigmatism having cataract surgery. Bilateral implantation of the AcrySof toric IOL was performed after phacoemulsification. The uncorrected visual acuity (UCVA), best corrected visual acuity (BCVA), residual refractive sphere, residual keratometric and refractive cylinders, and toric IOL axis were measured. RESU…
Investigation of cuticular hydrocarbons from Bagrada hilaris genders by SPME/GC-MS
2007
The cuticular hydrocarbons of male and female Bagrada hilaris Burmeister (Heteroptera: Pentatomidae) were investigated, by headspace solid-phase microextraction followed by gas chromatography-mass spectrometry. Measurements were done with fiber coatings of different polarity after optimization of headspace volumes and extraction temperatures. This resulted in the use of polyacrylate fiber, 22-ml vial as the sample holder, and an extraction temperature of 150 degrees C. The analytical procedures allowed identification of 13 peaks, corresponding to a homologous series of n-alkanes (nC(17)-nC(29)). The hydrocarbon profiles of male and female B. hilaris were qualitatively equal, but marked sex-…
Correlation of pupil size with visual acuity and contrast sensitivity after implantation of an apodized diffractive intraocular lens
2007
To determine whether pupil size is correlated with visual acuity and contrast sensitivity at all distances in eyes with an apodized diffractive intraocular lens (IOL).Private Clinic, Oviedo, Spain.Six months after surgery, the best corrected distance visual acuity, best distance-corrected near visual acuity, intermediate visual acuity, and distance contrast sensitivity under photopic (85 cd/m2) and mesopic (5 cd/m2) conditions were measured in 670 eyes of 335 consecutive patients who had implantation of the AcrySof ReSTOR Natural IOL (SN60D3, Alcon). Pupil diameters in distance vision were measured using a pupillometer.The logMAR best corrected distance acuity was significantly better with …
BPA, an Energy Balance Disruptor
2014
International audience; Bisphenol A (BPA) is used extensively in the world and is present in a diverse range of manufactured articles including dental resins, polycarbonate plastics, and the inner coating of food cans. It is a high volume chemical, with global production at 3.6 × 109 kg per year. BPA was identified as a high priority for assessment of human health risk because it was considered to present greatest potential for human exposure. Most studies of the health effects of BPA have focused on endocrine disruption leading to reproductive toxicity, but it displays additional side effects, including liver damage, disrupted pancreatic β-cell function, thyroid hormone disruption, and obe…
Prospective visual evaluation of apodized diffractive intraocular lenses
2006
To evaluate distance, intermediate, and near visual performance in patients who had multifocal apodized diffractive intraocular lens (IOL) implantation.Fernández-Vega Ophthalmological Institute, Oviedo, Spain.The best corrected distance visual acuity, best distance-corrected near visual acuity, intermediate visual acuity, distance contrast sensitivity under photopic and mesopic conditions, and patient satisfaction were measured in 325 patients and 335 patients who had bilateral implantation of the model SA60D3 IOL (AcrySof ReSTOR, Alcon) and model SN60D3 IOL (AcrySof Natural ReSTOR), respectively.At the 6-month postoperative visit, binocular best corrected distance acuity with the ReSTOR IO…
Prospective study of the Acri.LISA bifocal intraocular lens
2007
To assess the visual results after bilateral implantation of the bifocal Acri.LISA 366D intraocular lens (IOL) (Acri.Tec AG).Fernández-Vega Ophthalmological Institute, Oviedo, Spain.Eighty-one patients had bilateral implantation of the distance-dominant bifocal Acri.LISA 366D IOL in a prospective study. Monocular and binocular best corrected distance visual acuity and best distance-corrected near visual acuity, binocular best distance-corrected intermediate visual acuity, and distance contrast sensitivity under photopic (85 cd/m(2)) and mesopic (5 cd/m(2)) conditions were determined.At the 3-month postoperative visit, the mean binocular best corrected distance acuity was 0.048 +/- 0.111 log…
Clear Lens Extraction with Multifocal Apodized Diffractive Intraocular Lens Implantation
2007
Purpose To assess efficacy, safety, predictability, and stability after clear lens extraction (CLE) with multifocal diffractive intraocular lens (IOL) implantation. Design Prospective, nonrandomized, masked observational case series (self-controlled). Participants Two hundred twenty-four eyes of 112 consecutive patients after CLE with bilateral AcrySof ReSTOR Natural IOL implantation. Eyes were divided into myopic (mean spherical equivalent [SE], −6.01±2.71 diopters [D]) and hyperopic (mean SE, +3.86±2.52 D) groups. Methods Monocular and binocular uncorrected distance visual acuity (VA), best-corrected distance VA, uncorrected distance near VA, and best distance-corrected near VA were recor…
Sulcus implantation of a single-piece foldable acrylic intraocular lens after posterior capsular rupture in cataract surgery.
2012
Purpose. To evaluate the safety of a foldable acrylic single-piece intraocular lens (IOL) in cases of complicated cataract surgery and sulcus implantation. The setting was University and private anterior segment surgery practices. Methods. In this observational case series study, 13 eyes of 13 patients were included after complicated phacoemulsification with extensive posterior capsule rupture with or without vitreous loss. A foldable acrylic single-piece IOL (Rayner Superflex 620H; Rayner Intraocular Lenses Limited, Hove, East Sussex, UK) was implanted in the ciliary sulcus in each eye. Postoperative follow-up included best-corrected visual acuity, anterior segment biomicroscopy, IOL centr…
Lack of effect of intraocular lens asphericity on visual performance with acrylic intraocular lenses.
2011
Purpose. To determine whether implantation of acrylic intraocular lens (IOL) with aspheric design (Tecnis Z9003, AMO) results in improved visual acuity or contrast sensitivity compared with conventional spherical acrylic IOL (AR40e, AMO). Methods. In an intraindividual randomized prospective study of 60 patients with bilateral cataract, the Tecnis Z9003 IOL was compared with the AR40e IOL. Ocular aberrations for a 4.0-mm pupil and 6.0-mm pupil were measured with a Hartmann-Shack aberrometer. Quality of vision was measured using visual acuity and contrast sensitivity under mesopic and photopic conditions. Results. Eyes with the Tecnis Z9003 IOL had significantly less spherical aberration and…