Time-Gated Raman Spectroscopy for Quantitative Determination of Solid-State Forms of Fluorescent Pharmaceuticals

2018

Raman spectroscopy is widely used for quantitative pharmaceutical analysis, but a common obstacle to its use is sample fluorescence masking the Raman signal. Time-gating provides an instrument-based method for rejecting fluorescence through temporal resolution of the spectral signal and allows Raman spectra of fluorescent materials to be obtained. An additional practical advantage is that analysis is possible in ambient lighting. This study assesses the efficacy of time-gated Raman spectroscopy for the quantitative measurement of fluorescent pharmaceuticals. Time-gated Raman spectroscopy with a 128 X (2) X 4 CMOS SPAD detector was applied for quantitative analysis of ternary mixtures of sol…

Time Factorsspektroskopia116 Chemical sciencesAnalytical chemistry02 engineering and technologySpectrum Analysis Raman01 natural sciencesSignalAnalytical Chemistrysymbols.namesakeTime domainLeast-Squares Analysista116DETECTORFluorescent DyesSUPPRESSIONta113ta114Chemistry010401 analytical chemistryDetectorMIXTURESSENSORPIROXICAMRESONANCE021001 nanoscience & nanotechnologyRAY-POWDER DIFFRACTIONFluorescence0104 chemical sciencesSPADPharmaceutical PreparationsPHOTON AVALANCHE-DIODETemporal resolutionRaman spectroscopysymbolsCRYSTALLIZATION0210 nano-technologyRaman spectroscopyTernary operationQuantitative analysis (chemistry)
researchProduct

In-situ high spatial resolution LA-MC-ICPMS 230Th/U dating enables detection of small-scale age inversions in speleothems

2017

Abstract We present an in-situ method for Th and U isotope measurements by laser ablation multi-collector inductively coupled plasma mass spectrometry (LA-MC-ICPMS) to determine possible age inversions of stalagmites, using a 213 nm Nd:YAG laser connected to an MC-ICPMS. Due to the low ion beam intensity of 230 Th (20–120 counts per second, cps), we carefully optimized the operating parameters to get highest possible ion beam intensities, i.e., laser fluence (25 J cm −2 ), spot size (110 μm), pulse repetition rate (20 Hz), scan speed (4 μm s −1 ), integration time (1000 s), and He and Ar gas flow (∼0.9 L min −1 and ∼0.6 L min −1 respectively). A precision (2 relative standard error, 2RSE) o…

Time delay and integrationIon beamAnalytical chemistryMineralogy010502 geochemistry & geophysics01 natural scienceslaw.inventionGeochemistry and PetrologylawImage resolutionInductively coupled plasma mass spectrometry0105 earth and related environmental sciencesEarth-Surface ProcessesReproducibilityLaser ablationChemistry010401 analytical chemistrylcsh:QE1-996.5GeologySecular equilibriumGeotechnical Engineering and Engineering GeologyLaserSpeleothemLaser ablation0104 chemical scienceslcsh:Geology230Th/U datingGeophysicsMC-ICPMS
researchProduct

Determination of Synchronization of Electrical Activity in the Heart by Shannon Entropy Measure

2005

In this paper we propose a new index of synchronization for the study of heart’s electrical activity during atrial fibrillation (AF). The index relies on the measure of the time delays between correspondent activations in two atrial electrograms and on the characterization of their dispersion by a measure of Shannon Entropy. The algorithm was validated on simulated signals mimicking different degree of synchronization. Results showed the index was able to discriminate among different levels of organization, provided that it works on series of at least 50 activations (time resolution of almost 10 sec during AF). Moreover, we applied the algorithm to real bipolar electrograms, obtained from a…

Time delaysSeries (mathematics)business.industryAtrial fibrillationTime resolutionPattern recognitionmedicine.diseaseMeasure (mathematics)SynchronizationEngineering (all)medicine.anatomical_structureControl theorySettore ING-INF/06 - Bioingegneria Elettronica E InformaticamedicineRight atriumStatistical dispersionArtificial intelligencebusinessMathematics
researchProduct

An example of interplay between Physics and Mathematics: Exact resolution of a new class of Riccati Equations

2017

A novel recipe for exactly solving in finite terms a class of special differential Riccati equations is reported. Our procedure is entirely based on a successful resolution strategy quite recently applied to quantum dynamical time-dependent SU(2) problems. The general integral of exemplary differential Riccati equations, not previously considered in the specialized literature, is explicitly determined to illustrate both mathematical usefulness and easiness of applicability of our proposed treatment. The possibility of exploiting the general integral of a given differential Riccati equation to solve an SU(2) quantum dynamical problem, is succinctly pointed out.

Time-dependent HamiltonianClass (set theory)Solvable modelUnitary evolution.010102 general mathematicsGeneral Physics and AstronomyFOS: Physical sciencesMathematical Physics (math-ph)01 natural sciencesSettore FIS/03 - Fisica Della MateriaRiccati equation0103 physical sciencesComputingMethodologies_SYMBOLICANDALGEBRAICMANIPULATIONRiccati equationApplied mathematicsDifferential riccati equations0101 mathematics010306 general physicsQuantumDifferential (mathematics)Mathematical PhysicsMathematicsResolution (algebra)
researchProduct

High Resolution Time Domain Reflectometry for Dielectric State Monitoring in High Voltage Cables

2017

A high resolution Time Domain Reflectometry system has been designed in order to investigate the possibility of measuring with good accuracy the dielectric properties of high voltage cables insulator materials by means of Time-of-Flight measures. The system employs a dedicated Time-To-Digital Converter in order to achieve a time resolution of 90 ps. By exploiting averaging techniques the resolution has been further increased. Experimental results showed the possibility of measuring the dielectric constant with a resolution of 0.03%.

Time-of-Flight measurementMaterials sciencebusiness.industryHigh resolutionHigh voltageTime resolutionInsulator (electricity)DielectricDielectric state monitoringSettore ING-INF/01 - ElettronicaTime domain reflectometryTime-to-digital converterOptoelectronicsTime domainTime-to-Digital ConverterbusinessReflectometry
researchProduct

X-ray microtomography and laser ablation in the analysis of ink distribution in coated paper

2015

A novel method was developed for studying the ink-paper interface and the structural variations of a deposited layer of ink. Combining high-resolution x-ray tomography with laser ablation, the depth profile of ink (toner), i.e., its varying thickness, could be determined in a paper substrate. X-ray tomography was used to produce the 3D structure of paper with about 1 μm spatial resolution. Laser ablation combined with optical imaging was used to produce the 3D structure of the printed layer of ink on top of that paper with about 70 nm depth resolution. Ablation depth was calibrated with an optical profilometer. It can be concluded that a toner layer on a light-weight-coated paper substrate …

TopographyCoated paperLaser ablationX-ray microtomographyMaterials scienceta114Inkwellbusiness.industrymedicine.medical_treatmentGeneral Physics and AstronomySurface structureLaserAblationLaser ablationImage analysislaw.inventionOpticslawmedicineProfilometerta216businessTomographyImage resolutionJournal of Applied Physics
researchProduct

Resolution of the photon scanning tunneling microscope: influence of physical parameters

1992

Abstract The photon scanning tunneling microscope (PSTM) is the photon analogue of the electron scanning tunneling microscope (ESTM). It uses the evanescent field due to total internal reflection (TIR) of a light beam in a prism modulated by a sample placed on the base of the prism. Our experimental results shown details which present a lateral size as small as 200 A. The PSTM axial resolution is more difficult to evaluate. It is a function of the roughness of the sample. For very smooth samples, images shown an axial resolution of about 10 A. At last we discuss how both lateral and axial resolution can be affected by several parameters such as the tip surface distance and the roughness of …

Total internal reflectionScanning Hall probe microscopeChemistrybusiness.industryResolution (electron density)Scanning tunneling spectroscopySpin polarized scanning tunneling microscopyAtomic and Molecular Physics and OpticsElectronic Optical and Magnetic Materialslaw.inventionScanning probe microscopyOpticslawPrismScanning tunneling microscopebusinessInstrumentationUltramicroscopy
researchProduct

In-situ reflectance spectroscopy - analysing techniques for high-resolution pigment logging in sediment cores

2003

The temporal resolution of marine proxy data is limited by analytically required sample size. We present in-situ reflectance spectroscopy techniques (usually applied in remote sensing) to analyse the organic fraction of marine and terrestrial sediment. From absorption band depths, photosynthesis pigment variations are derived for sediments from the upwelling region off Peru, where productivity is related to the annual variability of El Nino strength. Quantitative estimations of diagenetic photosynthesis pigments derived from absorption band analysis in reflectance spectra are highly correlated to organic carbon content. The ratio of pigment fractions is related to chlorine concentration and…

Total organic carbonchemistry.chemical_classificationchemistryTerrigenous sedimentAbsorption bandTemporal resolutionGeneral Earth and Planetary SciencesSedimentMineralogyUpwellingOrganic matterGeologyDiagenesisInternational Journal of Earth Sciences
researchProduct

Rapid determination of sterols in vegetable oils by CEC using methacrylate ester-based monolithic columns

2008

A method for the determination of sterols in vegetable oils by CEC with UV-Vis detection, using methacrylate ester-based monolithic columns, has been developed. To prepare the columns, polymerization mixtures containing monomers of different hydrophobicities were tried. The influence of composition of polymerization mixture was optimized in terms of porogenic solvent, monomers/porogens and monomer/crosslinker ratios. The composition of the mobile phase was also studied. The optimum monolith was obtained with lauryl methacrylate monomer at 60:40% (wt:wt) lauryl methacrylate/ethylene dimethacrylate ratio and 60 wt% porogens with 20 wt% of 1,4-butanediol (12 wt% 1,4-butanediol in the polymeriz…

TrisDetection limitgeographygeography.geographical_feature_categoryChromatographyResolution (mass spectrometry)ChemistryClinical BiochemistryPhytosterolsReproducibility of ResultsMethacrylateSensitivity and SpecificityBiochemistryAnalytical ChemistrySolventchemistry.chemical_compoundMonomerPolymethacrylic AcidsPolymerizationCapillary ElectrochromatographyMethacrylatesPlant OilsMonolithHydrophobic and Hydrophilic InteractionsFood AnalysisELECTROPHORESIS
researchProduct

Enantioseparation of nuarimol by affinity electrokinetic chromatography-partial filling technique using human serum albumin as chiral selector

2008

The present paper deals with the enantiomeric separation of nuarimol enantiomers by affinity EKC-partial filling technique using HSA as chiral selector. Firstly, a study of nuarimol interactions with HSA by CE-frontal analysis was performed. The binding parameters obtained for the first site of interaction were n(1) = 0.84; K(1) = 9.7 +/- 0.3x10(3 )M(-1) and the protein binding percentage of nuarimol at physiological concentration of HSA was 75.2 +/- 0.2%. Due to the moderate affinity of nuarimol towards HSA the possibility of using this protein as chiral selector for the separation of nuarimol using the partial filling technique was evaluated. A multivariate optimization approach of the mo…

TrisResolution (mass spectrometry)Analytical chemistryFiltration and SeparationChromatography AffinityAnalytical ChemistryChemometricschemistry.chemical_compoundCapillary electrophoresismedicineAnimalsHumansSerum AlbuminChromatographyMolecular StructureReproducibility of ResultsStereoisomerismHuman serum albuminbody regionsElectrophoresisPyrimidineschemistryFemaleEnantiomerQuantitative analysis (chemistry)Softwaremedicine.drugJournal of Separation Science