Search results for "Restenosi"

showing 10 items of 76 documents

Diagnostic accuracy of 64-slice CT in the assessment of coronary stents

2007

PURPOSE: The purpose of this study was to assess the diagnostic accuracy of 64-slice computed tomography (64-CT) coronary angiography in the detection of coronary in-stent restenosis. MATERIALS AND METHODS: Ninety-five patients (72 men and 23 women, mean age 58+/-8 years) with previous percutaneous coronary intervention with stenting and suspected restenosis underwent 64-CT (Sensation 64, Siemens). The mean time between stent deployment and 64-CT was 6.1+/-4.2 months. The scan parameters were: slices 32 x 2, individual detector width 0.6 mm, rotation time 0.33 s, feed 3.84 mm/rotation, 120 kV, 900 mAs. After the intravenous administration of iodinated contrast material (Iomeprol 400 mgI/ml,…

Malemedicine.medical_specialtymedicine.medical_treatmentCoronary AngiographyCoronary RestenosisRestenosisIodinated contrastcoronary stentsHumansMedicineRadiology Nuclear Medicine and imagingSalineNeuroradiologymedicine.diagnostic_testbusiness.industryUltrasoundReproducibility of ResultsPercutaneous coronary interventionInterventional radiologyGeneral MedicineMiddle Agedmedicine.diseaseFemaleStentsRadiologyBolus (digestion)Tomography X-Ray ComputedbusinessRadiologia Medica
researchProduct

Usefulness of multislice computed tomography to assess patency of coronary artery stents versus conventional coronary angiography

2008

BACKGROUND: The aim of the present study was to assess the in-stent restenosis and occlusion of coronary artery stents by multislice computed tomography (MSCT) compared with conventional coronary angiography in patients with atypical chest pain and not practicable/non-conclusive stress test. METHODS: Between December 2004 and March 2006, 81 patients were scheduled and of these 72 (65 men, mean age 61 years) with 90 stents underwent MSCT angiography using a 16-slice scanner, Toshiba Aquilion 16, 8-12 months after stent placement. RESULTS: Of the 90 stents, 71 (79%) could be assessed and 19 (21%) were excluded because the image quality at the stent level was incompatible with diagnostic asses…

Malemedicine.medical_specialtymedicine.medical_treatmentCoronary AngiographySensitivity and SpecificityComputed tomography angiography Coronary stents Multidetector computed tomography Non-invasive imagingCoronary RestenosisRestenosisPredictive Value of TestsPositive predicative valueOcclusionmedicineHumanscardiovascular diseasesmedicine.diagnostic_testbusiness.industryStentGeneral MedicineMultislice computed tomographyMiddle Agedequipment and suppliesmedicine.diseaseCoronary Vesselssurgical procedures operativemedicine.anatomical_structureConcomitantAngiographyFemaleStentsRadiologyTomography X-Ray ComputedCardiology and Cardiovascular MedicinebusinessArteryJournal of Cardiovascular Medicine
researchProduct

Results of intracoronary stents for management of coronary dissection after balloon angioplasty.

1991

Dissections after coronary balloon angioplasty are risk factors for acute or subacute vessel closures. Intracoronary stenting was developed to avoid these complications by pressing the intimal and medial flaps against the vessel wall, thus reducing the risk of acute thrombosis. A total of 22 stents were implanted into the coronary arteries of 15 patients with dissections after balloon angioplasty causing angina pectoris or ischemic electrocardiographic changes. Stent delivery was successful in all cases. In 1 patient acute stent thrombosis was documented and treated successfully by thrombolytic therapy. Another patient underwent coronary artery bypass surgery 24 hours later because of persi…

Malemedicine.medical_specialtymedicine.medical_treatmentCoronary DiseaseBalloonAngina PectorisAnginaCoronary artery bypass surgeryRestenosisInternal medicineAngioplastyMedicineHumanscardiovascular diseasesAngioplasty Balloon CoronaryAgedRupturebusiness.industryStentMiddle Agedequipment and suppliesmedicine.diseaseCoronary VesselsSurgeryCoronary arteriesRadiographyDissectionmedicine.anatomical_structureCardiologyFemaleStentsCardiology and Cardiovascular MedicinebusinessThe American journal of cardiology
researchProduct

Comparison of myocardial perfusion reserve before and after coronary balloon predilatation and after stent implantation in patients with postangiopla…

1996

Background Stents provide a scaffold for coronary arteries after angioplasty and inhibit elastic recoil. Methods and Results In 25 patients with postangioplasty restenosis of the left anterior descending artery, ECG-gated digital subtraction coronary angiograms were recorded at baseline and during hyperemia (12 mg papaverine IC) before and after balloon predilatation (PTCA), after implantation of a Palmaz-Schatz stent, and after 6 months. Densitometric evaluation revealed different time and density parameters to calculate two definitions of myocardial perfusion reserve (MPR1 and MPR2) and maximum flow ratio (MaxFR). Poststenotic MPR1 increased from 1.57±0.14 to 2.59±0.86 after PTCA and to …

Malemedicine.medical_specialtymedicine.medical_treatmentCoronary DiseaseBalloonCoronary AngiographyCatheterizationElastic recoilCoronary circulationAbsorptiometry PhotonPostoperative ComplicationsRestenosisRecurrencePhysiology (medical)Internal medicineAngioplastyCoronary CirculationMedicineHumansAngioplasty Balloon CoronaryAgedmedicine.diagnostic_testbusiness.industryStentReproducibility of ResultsMiddle Agedmedicine.diseaseCoronary VesselsCoronary arteriesmedicine.anatomical_structureAngiographyCardiologyFemaleStentsCardiology and Cardiovascular MedicinebusinessCirculation
researchProduct

Impact of endovascular treatment on clinical status and health-related quality of life.

2008

Background and Aims: Investigating the impact of percutaneous transluminal angioplasty (PTA) on clinical status and health related quality of life in patients with claudication and critical limb ischaemia (CLI). Material and Methods: 61 patients and 64 limbs underwent a primary PTA (30 claudication and 34 CLI cases). Clinical status was graded according to Ahn and Rutherford and ankle/brachial index (ABI). Quality of life was assessed using the Nottingham Health Profile (NHP) preoperatively, one month and one year after the procedure. Triplex scan evaluation of the treated arterial segment was carried out postoperatively and one year after the procedure. Results: Claudication: 24/27 patient…

Malemedicine.medical_specialtymedicine.medical_treatmentRevascularizationStatistics NonparametricRestenosisIschemiamedicineHumansProspective StudiesAgedLegbusiness.industryCritical limb ischemiaIntermittent Claudicationmedicine.diseaseIntermittent claudicationSurgeryNottingham Health ProfileTreatment OutcomeBypass surgeryAmputationQuality of LifeSurgeryFemalemedicine.symptombusinessClaudicationAngioplasty BalloonScandinavian journal of surgery : SJS : official organ for the Finnish Surgical Society and the Scandinavian Surgical Society
researchProduct

Physical characterization of alginate-Pluronic F127 gel for endoluminal NABDs delivery

2014

Here we focus the attention on the physical characteristics of a highly biocompatible hydrogel made up of crosslinked alginate and Pluronic F127 (PF127). This is a composite polymeric blend we propose for artery endoluminal delivery of an emerging class of molecules named nucleic acid based drugs (NABDs). The physical characterization of our composite gel, i.e. mesh size distribution and PF127-alginate mutual organization after crosslinking, can significantly determine the NABDs release kinetics. Thus, to explore these aspects, different technical approaches, i.e. rheology, low/high field NMR and TEM, were used. While rheology provided information at the macroscopic and nano-level, the othe…

Materials sciencegel pavingAlginatesKineticsComposite numberNanotechnologyPoloxamerMicellerestenosisRheologyalginateArterial wallMicellesDrug Carriersgel paving; rheology; NMR; alginate; Pluronic; restenosisGeneral ChemistryPluronicPoloxamerCondensed Matter PhysicsNMRCharacterization (materials science)Chemical engineeringSettore CHIM/09 - Farmaceutico Tecnologico ApplicativoSolute diffusionrheologyNABDs release kinetics PF127 alginate gel paved stent artery endoluminal deliveryGels
researchProduct

Dexamethasone dipropionate loaded nanoparticles of α-elastin-g-PLGA for potential treatment of restenosis.

2013

A graft copolymer of α-elastin with poly(lactic-co-glycolic) acid (PLGA) has been synthesized and successfully employed to produce nanoparticles. Exploiting the known biological activity of α-elastin to promote the maintenance of smooth muscle cells (SMCs) contractile phenotype and the antiproliferative effect of glucocorticoids, the aim of this research was to produce drug-loaded nanoparticles suitable for potential treatment of restenosis. In particular, nanoparticles of α-elastin-g-PLGA with a mean size of 200 nm have been produced and loaded with dexamethasone dipropionate (10% w/w), chosen as a model drug that inhibits proliferation of vascular SMCs. These nanoparticles are able to pro…

Myocytes Smooth MusclePharmaceutical ScienceDexamethasoneMuscle Smooth VascularCoronary Restenosischemistry.chemical_compoundPolylactic Acid-Polyglycolic Acid CopolymerDrug DiscoveryMyocyteAnimalsHumansLactic AcidParticle SizeCells CulturedCell ProliferationDrug CarriersbiologyCell growthElastaseBiological activityCell DifferentiationElastinBlotPLGAchemistryBiochemistryBiophysicsbiology.proteinMolecular MedicineNanoparticlesCattleDrug carrierElastinPolyglycolic AcidMolecular pharmaceutics
researchProduct

Short-term atorvastatin treatment does not modify neointimal morphology but reduces MMP-2 expression in normocholesterolemic rabbit stented arteries.

2006

The aim of our study was to explore some potential pleiotropic effects of atorvastatin, after stenting in the iliac arteries of normocholesterolemic rabbits. On day 0, 27 rabbits underwent stent implantation and were randomized into either the control group (standard chow, CTRL, n = 15) or the atorvastatin group (10 mg/kg/d per os, Ator, n = 12). On day 30, the stented arteries were harvested for histomorphometry and neointimal analysis [macrophages, matrix metalloproteinases (MMP-2), tissue inhibitor of metalloproteinase-2, vascular smooth muscle cells, and collagen]. Atorvastatin did not induce significant histomorphometric and inflammatory modifications but reduced neointimal expression …

NeointimaMalemedicine.medical_specialtyStatinVascular smooth musclemedicine.drug_classAtorvastatinHypercholesterolemiaUrologyMatrix metalloproteinaseIliac ArteryMuscle Smooth VascularRestenosisInternal medicinemedicineAtorvastatinAnimalsPyrrolesPharmacologyTissue Inhibitor of Metalloproteinase-2Cellular densityChemistrymedicine.diseaseImmunohistochemistryHeptanoic AcidsCardiologyMatrix Metalloproteinase 2StentsStatin therapyRabbitsHydroxymethylglutaryl-CoA Reductase InhibitorsCardiology and Cardiovascular MedicineTunica Intimamedicine.drugJournal of cardiovascular pharmacology
researchProduct

Rapamycin vermindert die Neointimaausbildung nach vaskulärer Schädigung

2003

Background: Proliferation and migration of vascular smooth muscle cells (SMCs) mark the key processes in the development of bypass graft disease and during neointima formation in restenosis after angioplasty. Growth factors are potent SMC mitogens as they are involved in SMC proliferation and in extracellular matrix (ECM) synthesis. Based on these premises, we examined the effect of the proliferation inhibitor rapamycin in human SMC culture and in a rabbit vascular injury model. Materials and methods: Injection of rapamycin or its vehicle was performed with an infusion-balloon catheter directly into the vessel wall during vascular injury. The intima/media ratio was determined histologicall…

NeointimaPathologymedicine.medical_specialtyVascular smooth musclebiologybusiness.industryVascular diseaseCell growthVimentinPharmacologymedicine.diseaseExtracellular matrixRestenosisSirolimuscardiovascular systembiology.proteinMedicineCardiology and Cardiovascular Medicinebusinessmedicine.drugVasa
researchProduct

Adenoviral RB2/p130 gene transfer inhibits smooth muscle cell proliferation and prevents restenosis after angioplasty.

1999

Abstract —Smooth muscle cell (SMC) proliferation that results in neointima formation is implicated in the pathogenesis of atherosclerotic plaques and accounts for the high rates of restenosis that occur after percutaneous transluminal coronary angioplasty, a widespread treatment for coronary artery disease. Endothelial lesions trigger intense proliferative signals to the SMCs of the subintima, stimulating their reentry into the cell cycle from a resting G 0 state, resulting in neointima formation and vascular occlusion. Cellular proliferation is negatively controlled by growth-regulatory or tumor-suppressor genes, or both, such as the retinoblastoma gene family members ( RB/p105, p107, RB2…

NeointimaTranscriptional Activationmedicine.medical_specialtyPhysiologyadenovirus; cell cycle; gene therapy; p130; prb2; restenosisCellGenetic VectorsCell Cycle ProteinsPulmonary ArteryMuscle Smooth VascularAdenoviridaeCatheterizationPathogenesisRestenosisRecurrencemedicineAnimalsCarotid StenosisAngioplasty Balloon CoronaryGenes RetinoblastomaCells CulturedNeointimal hyperplasiaWound HealingRetinoblastoma-Like Protein p130business.industryCell growthGenetic transferCell CycleProteinsGenetic TherapyCell cyclemedicine.diseasePhosphoproteinsSurgeryE2F Transcription FactorsRatsDNA-Binding Proteinsmedicine.anatomical_structureCancer researchCardiology and Cardiovascular MedicinebusinessCarotid Artery InjuriesCarrier ProteinsTunica IntimaTranscription Factor DP1Cell DivisionRetinoblastoma-Binding Protein 1Transcription FactorsCirculation research
researchProduct