Search results for "Rhythm"
showing 10 items of 822 documents
Reproducibility of electrocardiographic findings in patients with suspected reflex neurally-mediated syncope
2008
The reproducibility of electrocardiographic (ECG) recordings in syncopal recurrences and the diagnostic role of nonsyncopal arrhythmias are not well known. The objective of this study was to analyse the reproducibility of the ECG findings recorded with implantable loop recorders in 41 patients with suspected neurally-mediated syncope who were included in the International Study on Syncope of Uncertain Origin-2 study and that had > or =2 events recorded by implantable loop recorders. In these patients, the electrocardiogram obtained with the first documented syncope (index syncope) was compared with other recorded events. Twenty-two patients had > or =2 syncopes, and their electrocardiograms…
A Hospital-Based and a Population-Based Stroke Registry Yield Different Results: The Experience in Dijon, France
1996
The aim of this study was to demonstrate the different results obtained from a population-based and a hospital-based stroke study in the same city.Between January 1 and December 31, 1993, we collected information on all of the first strokes in the population of the city of Dijon, in conjunction with the Dijon Stroke Registry, collecting the first-ever strokes from patients living in Dijon as well as on all the first strokes in residents and nonresidents of Dijon who were treated at Dijon University Hospital. Demographic details, medical history, vascular risk factors, stroke subtype, as diagnosed by CT scan, and mortality rates were compared between the strokes observed in the population of…
Electrophysiological characterization of the pineal gland of golden hamsters.
1987
In one of the most-widely used species in pineal gland research, the strongly photoperiodic golden hamster, Mesocricetus auratus, no electrophysiological data on pinealocytes are currently available. To fill this gap, in the present study 185 spontaneously active pinealocytes from male golden hamsters were recorded extracellularly, both during day- and night-time (light: dark cycle 12 ∶ 12, lights on at 07.00 h). As in other species, pinealocytes exhibited action potentials of 1–2 ms duration. An irregular firing pattern was observed in 95% of the pinealocytes, the remainder fired more regularly or showed a phasic discharge pattern. The firing frequencies ranged from 0.2 to 25 Hz and showed…
Effects of alterations in sympathetic nervous activity on the severity of reperfusion-induced arrhythmias in anaesthetised rats.
1987
The effects of a number of interventions influencing sympathetic nervous activity on the severity of coronary artery reperfusion-induced arrhythmias in anaesthetised rats have been examined. Noradrenaline (0.1 microgram kg-1 min-1) reduced the mortality that usually occurred as a consequence of ventricular fibrillation. Isoprenaline (5 micrograms kg-1) did not significantly affect the severity of reperfusion-induced arrhythmias, although arrhythmias occurring during the 5-min period of ischaemia were exacerbated. The alpha-adrenoceptor antagonist nicergoline (0.25 and 0.5 mg kg-1 min-1) markedly suppressed both the ventricular tachycardia and fibrillation occurring upon release of the occlu…
Cardiac sympathetic activation and parasympathetic withdrawal during psychosocial stress exposure in 6‐month‐old infants
2020
Infant autonomic reactivity to stress is a potential predictor of later life health complications, but research has not sufficiently examined sympathetic activity, controlled for effects of physical activity and respiration, or studied associations among autonomic adjustments, cardiac activity, and affect in infants. We studied 278 infants during the repeated Still-Face Paradigm, a standardized stressor, while monitoring cardiac activity (ECG) and respiratory pattern (respiratory inductance plethysmography). Video ratings of physical activity and affect were also performed. Respiratory sinus arrhythmia (RSA) and T-wave amplitude (TWA) served as noninvasive indicators of cardiac parasympathe…
Cardiac involvement in rheumatoid arthritis: Evidence of silent heart disease
1995
Background : Rlieumatoid arthritis (RA) is a systemic disease involving many organ systems and is frequently accompanied by cardiac alterations. However, there is considerable disagreement concerning the cardiac abnormalities found in patients with RA. The purpose of our investigation was to determine, by a non-invasive method such as echocardiography, the nature and extent of cardiac involvement in RA patients with no symptoms of cardiac disease, in comparison with a control sample. Methods : We selected 35 patients affected by rheumatoid arthritis (five men, 30 women), aged 51 ± 11 years. No patient had either symptoms of cardiac disease or extra cardiac complaint. As a control group we s…
Biphasic 24-Hour Variations in Cyclic GMP Accumulation in the Rat Pineal Gland Are Due to Corresponding Changes in the Activity of Cytosolic and Part…
2006
Various parameters of the rat pineal gland display a 24-h rhythm. However, nothing is known about possible 24-h variations in cyclic GMP (cGMP) metabolism. In the present study, 24-h variations in pineal gland cGMP accumulation were investigated by determining the increase in cGMP level with and without inhibitors of phosphodiesterase at different time points over a light/dark cycle (12/12 h). Furthermore, the activity of guanylate cyclase (GC) was determined under substrate-saturated conditions regarding the cytosolic and particulate forms of the enzyme. It has been found that cGMP accumulation and GC activity display biphasic 24-h variations with two peaks--one approximately 7 h after lig…
Sudden cardiac death while wearing a Holter monitor
1991
The Holter tapes of 61 patients (46 men, mean age +/- standard deviation 65 +/- 11 years) with sudden cardiac death while being monitored were analyzed. Thirty-eight patients were known to have coronary artery disease, 5 had cardiomyopathy, and 7 had aortic valve disease. Etiology remained unknown in 11 patients. Mean New York Heart Association functional class was 2.5 +/- 0.7. Thirty patients had received antiarrhythmic drugs and 32 had received digitalis. Sudden death occurred at rest in 73%. In the hours before death, repetitive ventricular arrhythmias were found in 50 patients (82%), with atrial fibrillation in 34%. Patients with bradyarrhythmic death (18%) had less complex ventricular …
Finding atrial fibrillation in stroke patients: Randomized evaluation of enhanced and prolonged Holter monitoring—Find-AFRANDOMISED —rationale and de…
2014
Background Detecting paroxysmal atrial fibrillation (AF) in patients with ischemic strokes presenting in sinus rhythm is challenging because episodes are often short, occur randomly, and are frequently asymptomatic. If AF is detected, recurrent thromboembolism can be prevented efficiently by oral anticoagulation. Numerous uncontrolled studies using various electrocardiogram (ECG) devices have established that prolonged ECG monitoring increases the yield of AF detection, but most established procedures are time-consuming and costly. The few randomized trials are mostly limited to cryptogenic strokes. The optimal method, duration, and patient selection remain unclear. Repeated prolonged conti…
Relationship between HRV measurements and demographic and clinical variables in a population of patients with atrial fibrillation.
2015
Little is known about the role of HRV in atrial fibrillation (AF) patients. Aim of our study was to assess the relationship between HRV measurements and demographic and clinical variables in a population of 274 AF patients. We selected all consecutive patients with persistent/permanent AF among whom had performed a Holter ECG in our Department from April 2010 to April 2015. Time-domain analysis of HRV was evaluated. Demographic and clinical variables were collected for each patient. At multivariable logistic regression, a higher pNN50 was associated with ACE inhibitors/ARBs (p = 0.016) and a lower pNN50 with obesity (p = 0.037) and higher heart rate (HR) (p < 0.0005). A higher RMSSD w…