Search results for "SAGE"

showing 10 items of 1373 documents

Estimation of external gamma radiation dose in the area of Bory Stobrawskie forests (PL).

2011

The study assessed the radiological risks associated with the presence of natural and artificial radionuclides in the Bory Stobrawskie forests (PL). Using the conversion factors given by UNSCEAR and the measurements results of (232)Th series, (238)U series, (40)K, and (137)Cs specific activities in the 10-cm soil layer the values of absorbed dose (D) and the annual effective dose equivalent derived from terrestrial gamma radiation (E) were calculated. The calculated dose was compared with doses directly measured on the area studied.

RadiationManagement Monitoring Policy and LawRadiation DosageArticleTreesEnvironmental Science(all)Radiation MonitoringHumansSoil Pollutants RadioactiveGeneral Environmental ScienceRadionuclidesRadionuclideRadiation doseRadiochemistryRadiation doseGamma rayGeneral MedicineEnvironmental exposureEnvironmental ExposurePollutionRadiological hazardGamma RaysAbsorbed doseRadiation monitoringEnvironmental sciencePolandEnvironmental monitoring and assessment
researchProduct

A practical and transferable methodology for dose estimation in irradiated spices, based on thermoluminescence dosimetry

2008

Abstract The thermoluminescence technique is recommended by the European Committee for Standardization for the detection of irradiated food containing silicates as contaminants. In this work, the applicability of the thermoluminescence technique as a quantitative method to assess the original dose in irradiated oregano was studied; the additive-dose method was used, with reirradiation doses up to 600 Gy. The proposed new procedure allows to clearly discriminate irradiated from unirradiated samples, even after one year storage, and it gives an acceptable estimation of the original dose; the overall modified procedure requires only one day to be completed.

RadiationMaterials scienceThermoluminescence irradiated fooddosimetryfood irradiationRadiochemistryReproducibility of ResultsRadiation DosageSensitivity and SpecificityThermoluminescenceSettore FIS/07 - Fisica Applicata(Beni Culturali Ambientali Biol.e Medicin)Dose estimationThermoluminescent Dosimetrythermoluminescence irradied spicesDosimetryThermoluminescent DosimetryRadurizationFood irradiationThermoluminescence dosimetryIrradiationSpicesFood Contamination RadioactiveFood Analysisthermoluminescence
researchProduct

Monte Carlo dosimetric study of the medium dose rate CSM40 source

2013

Abstract The 137Cs medium dose rate (MDR) CSM40 source model (Eckert & Ziegler BEBIG, Germany) is in clinical use but no dosimetric dataset has been published. This study aims to obtain dosimetric data for the CSM40 source for its use in clinical practice as required by the American Association of Physicists in Medicine (AAPM) and the European Society for Radiotherapy and Oncology (ESTRO). Penelope2008 and Geant4 Monte Carlo codes were used to characterize this source dosimetrically. It was located in an unbounded water phantom with composition and mass density as recommended by AAPM and ESTRO. Due to the low photon energies of 137Cs, absorbed dose was approximated by collisional kerma. Add…

RadiationPhotonPhantoms Imagingbusiness.industryChemistryRadiotherapy Planning Computer-Assistedmedicine.medical_treatmentMonte Carlo methodBrachytherapyWaterRadiotherapy DosageImaging phantomComputational physicsKermaCesium RadioisotopesAbsorbed dosemedicineAnisotropyHumansRadiometryNuclear medicinebusinessRadiation treatment planningMonte Carlo MethodUncertainty analysisApplied Radiation and Isotopes
researchProduct

Dosimetric feasibility study for an extracorporeal BNCT application on liver metastases at the TRIGA Mainz

2010

This study investigates the dosimetric feasibility of Boron Neutron Capture Therapy (BNCT) of explanted livers in the thermal column of the research reactor in Mainz. The Monte Carlo code MCNP5 is used to calculate the biologically weighted dose for different ratios of the (10)B-concentration in tumour to normal liver tissue. The simulation results show that dosimetric goals are only partially met. To guarantee effective BNCT treatment the organ has to be better shielded from all gamma radiation.

Radiationbusiness.industryLiver NeoplasmsBoron Neutron Capture TherapyRadiotherapy DosageModels BiologicalExtracorporealTRIGANeutron captureMonte carlo codeLiver tissueHumansMedicineComputer SimulationRadiometryNuclear medicinebusinessApplied Radiation and Isotopes
researchProduct

Monte Carlo dosimetric study of the BEBIG Co-60 HDR source

2005

Although not as widespread as Ir-192, Co-60 is also available on afterloading equipment devoted to high dose rate brachytherapy, mainly addressed to the treatment of gynaecological lesions. The purpose of this study is to obtain the dosimetric parameters of the Co-60 source used by the BEBIG MultiSource remote afterloader (BEBIG GmbH, Germany) for which there are no dosimetric data available in the literature. The Monte Carlo code GEANT4 has been used to obtain the TG43 parameters and the 2D dose rate table in Cartesian coordinates of the BEBIG Co-60 HDR source. The dose rate constant, radial dose function and anisotropy function have been calculated and are presented in a tabular form as w…

Radiological and Ultrasound TechnologyPhantoms ImagingComputer scienceRadiotherapy Planning Computer-AssistedBrachytherapyMonte Carlo methodWaterRadiotherapy DosageHigh-Dose Rate BrachytherapyMonte carlo codeAnisotropyHumansRadiology Nuclear Medicine and imagingCobalt RadioisotopesRadiometryRadiation treatment planningDose rateMonte Carlo MethodAlgorithmSoftwareSimulationPhysics in Medicine and Biology
researchProduct

End-to-end tests using alanine dosimetry in scanned proton beams

2018

This paper describes end-to-end test procedures as the last fundamental step of medical commissioning before starting clinical operation of the MedAustron synchrotron-based pencil beam scanning (PBS) therapy facility with protons. One in-house homogeneous phantom and two anthropomorphic heterogeneous (head and pelvis) phantoms were used for end-to-end tests at MedAustron. The phantoms were equipped with alanine detectors, radiochromic films and ionization chambers. The correction for the 'quenching' effect of alanine pellets was implemented in the Monte Carlo platform of the evaluation version of RayStation TPS. During the end-to-end tests, the phantoms were transferred through the workflow…

Radiology Nuclear Medicine and ImagingMaterials sciencePelviMonte Carlo methodanthropomorphic phantomauditRadiation DosageImaging phantom030218 nuclear medicine & medical imaginglaw.inventionPelvisSynchrotron03 medical and health sciences0302 clinical medicinelawIonizationend to end testDosimetryHumansPencil-beam scanningRadiometryAlaninedosimetryRadiological and Ultrasound TechnologyPhantoms ImagingRadiotherapy Planning Computer-Assistedequipment and suppliesSynchrotron030220 oncology & carcinogenesisIonization chamberProtonProtonsHeadMonte Carlo MethodBeam (structure)SynchrotronsBiomedical engineeringHuman
researchProduct

Analysis of random walks on a hexagonal lattice

2019

We consider a discrete-time random walk on the nodes of an unbounded hexagonal lattice. We determine the probability generating functions, the transition probabilities and the relevant moments. The convergence of the stochastic process to a 2-dimensional Brownian motion is also discussed. Furthermore, we obtain some results on its asymptotic behavior making use of large deviation theory. Finally, we investigate the first-passage-time problem of the random walk through a vertical straight-line. Under suitable symmetry assumptions we are able to determine the first-passage-time probabilities in a closed form, which deserve interest in applied fields.

Random walk01 natural sciences010104 statistics & probabilityModerate deviations0103 physical sciencesFOS: MathematicsHexagonal latticeHexagonal latticeProbability-generating functionStatistical physics0101 mathematics010306 general physicsBrownian motionMathematicsStochastic processApplied MathematicsProbability (math.PR)Random walkSymmetry (physics)Random walk; Hexagonal lattice; Probability generating function; Large deviations; Moderate deviations; First-passage timeSettore MAT/06 - Probabilita' e Statistica MatematicaLarge deviationsProbability generating functionLarge deviations theoryFirst-hitting-time modelMathematics - Probability60J15 60F10 82C41First-passage time
researchProduct

Spectral interest points and texture extraction and fusion for identification, control and security

2018

Biometrics is an emerging technology that proposes new methods of control, identification and security. Biometric systems are often subject to risks. Face recognition is popular and several existing approaches use images in the visible spectrum. These traditional systems operating in the visible spectrum suffer from several limitations due to changes in lighting, poses and facial expressions. The methodology presented in this thesis is based on multispectral facial recognition using infrared and visible imaging, to improve the performance of facial recognition and to overcome the deficiencies of the visible spectrum. The multispectral images used in this study are obtained by fusion of visi…

Reconnaissance de visage[INFO.INFO-CV] Computer Science [cs]/Computer Vision and Pattern Recognition [cs.CV]Visible infrarougeAnalyse multi-ComposanteDescripteurDetectorTextureDescriptorFace recognitionDetecteurVisible infraredMultimodal analysis
researchProduct

Selection of optimal narrowband multispectral images for face recognition

2015

Face recognition systems based on ’conventional’ images have reached a significant level of maturity with some practical successes. However, their performance may degrade under poor and/or changing illumination. Multispectral imagery represents a viable alternative to conventional imaging in the search for a robust and practical identification system. Multi- spectral imaging (MI) can be defined as a ’collection of several monochrome images of the same scene, each of them taken with additional receptors sensitive to other frequencies of the visible light or to frequencies beyond the visible light like the infrared region of electro- magnetic continuum. Each image is referred to as a band or …

Reconnaissance de visage[INFO.INFO-TI] Computer Science [cs]/Image Processing [eess.IV]Visible spectrumVision par ordinateurMulti-spectral ImagesSpectre visibleComputer visionOptimisationImages multi-spectraleFace recognition
researchProduct

Smartphone viewing distance during active or passive tasks and relation to heterophoria

2019

Our aim was to analyze viewing distance for smartphone users (aged 18-45 y.) in terms of passive or active task, relation to heterophoria, type of refractive error and smartphone font size. Participants were asked to read out loud text message (passive task) and afterwards rewrite the same text and send back (active task). For the text message we used sentence consisting of 23 words and 200 characters (with spaces). Participants used their own smartphones (font size monitored). For both passive and active task we measured task time and viewing distance at the end of the task. We found significantly shorter viewing distance for digital active task compared to passive task (29.3 ± 4.7 and 32.…

Refractive errorComputer sciencebusiness.industryHeterophoriamedicineComputer visionArtificial intelligencemedicine.diseasebusinessAccommodationText messageTask (project management)Fourth International Conference on Applications of Optics and Photonics
researchProduct