Pulse shape analysis of signals from BaF2 and CeF3 scintillators for neutron capture experiments

2006

The scope of this work is to study the characteristics of BaF2 and CeF3 signals using fast digitizers, which allow the sampling of the signal at very high frequencies and the application of the fitting method for analysis of the recorded pulses. By this procedure particle identification and the reconstruction of pile-up events can be improved, while maintaining the energy and time-of-flight resolution as compared to traditional methods. The reliability of the technique and problems connected with data acquisition are discussed with respect to accurate measurements of neutron capture cross-sections.

PhysicsNuclear and High Energy PhysicsNeutron captureData acquisitionSampling (signal processing)AcousticsScintillatorInstrumentationSignalReliability (statistics)Particle identificationEnergy (signal processing)Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
researchProduct

Multi-pixel Geiger-mode avalanche photodiode and wavelength shifting fibre readout of plastic scintillator counters of the EMMA underground experiment

2009

The results of a development of a scintillator counter with wavelength shifting (WLS) fibre and a multi-pixel Geiger-mode avalanche photodiode readout are presented. The photodiode has a metal-resistor-semiconductor layered structure and operates in the limited Geiger mode. The scintillator counter has been developed for the EMMA underground cosmic ray experiment.

PhysicsNuclear and High Energy PhysicsOptical fiberPhysics - Instrumentation and DetectorsPixelbusiness.industryPhysics::Instrumentation and DetectorsAstrophysics::Instrumentation and Methods for AstrophysicsFOS: Physical sciencesPhysics::Physics EducationCosmic rayInstrumentation and Detectors (physics.ins-det)ScintillatorAvalanche photodiodePhotodiodelaw.inventionWavelengthOpticslawGeiger counterOptoelectronicsbusinessInstrumentation
researchProduct

Digital pulse-timing technique for the neutron detector array NEDA

2015

WOS: 000348040900011

PhysicsNuclear and High Energy PhysicsPhotomultiplierLiquid scintillatorPhysics::Instrumentation and Detectorsbusiness.industryNeutron detectorDetectorConstant fraction discriminatorNEDAZero crossingParticle detectorOpticsDigital timingSampling (signal processing)BC501AScintillation counterConstant fraction discriminatorNeutron detection[PHYS.PHYS.PHYS-INS-DET]Physics [physics]/Physics [physics]/Instrumentation and Detectors [physics.ins-det]businessInstrumentationComputingMilieux_MISCELLANEOUSNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
researchProduct

Test of digital neutron-gamma discrimination with four different photomultiplier tubes for the NEutron Detector Array (NEDA)

2014

WOS: 000344994600012

PhysicsNuclear and High Energy PhysicsPhotomultiplierNeutron-gamma discriminationLiquid scintillatorCharge Comparisonbusiness.industrydigitalTime-of-flightDetectorIntegrated rise-timeComparisonScintillatorNEDAChargeTime of flightOpticsDigital neutron-gamma discriminationPhotomultiplier tubeNeutron detectionNeutron[PHYS.PHYS.PHYS-INS-DET]Physics [physics]/Physics [physics]/Instrumentation and Detectors [physics.ins-det]businessInstrumentation
researchProduct

Plastic Scintillation Detectors for Time-of-Flight Mass Measurements

2020

Fast timing detectors are an essential element in the experimental setup for time-of-flight (ToF) mass measurements of unstable nuclei. We have upgraded the scintillator detectors used in experiments at the National Superconducting Cyclotron Laboratory (NSCL) by increasing the number of photomultiplier tubes that read out their light signals to four per detector, and characterized them in a test experiment with $^{48}$Ca beam at the NSCL. The new detectors achieved a time resolution ($\sigma$) of 7.5 ps. We systematically investigated different factors that affect their timing performance. In addition, we evaluated the ability of positioning the hitting points on the scintillator using the …

PhysicsNuclear and High Energy PhysicsPhotomultiplierScintillationPhysics - Instrumentation and DetectorsResolution (mass spectrometry)010308 nuclear & particles physicsbusiness.industryPhysics::Instrumentation and DetectorsDetectorFOS: Physical sciencesInstrumentation and Detectors (physics.ins-det)Scintillator01 natural sciencesTime of flightOpticsSuperconducting cyclotron0103 physical sciencesNuclear Experiment (nucl-ex)010306 general physicsbusinessInstrumentationNuclear ExperimentBeam (structure)
researchProduct

Low noise scintillation detectors with a P-47 thin layer screen for electrons of several keV

1994

Abstract The applicability of a low-noise scintillation detector (ScD) for the registration of electrons of several keV energy has been studied employing photomultipliers (PM) of different types and sizes. With the application of a sedimented P-47 scintillation screen, the values of the low-energy sensitivity limit and those of the light conversion coefficient were determined as about 2.7–4.7 keV and 2.8–6.6 photoelectrons/keV, respectively, for the set of PM's (Philips-Valvo XP 2020, Philips-Valvo XP 2052, Philips-Valvo XP 2972, EMI 9124a) studied. It is concluded that such scintillation detectors might be used advantageously as electron counters in the range of E > 5 keV. Applications bel…

PhysicsNuclear and High Energy PhysicsPhotomultiplierScintillationRange (particle radiation)Physics::Instrumentation and Detectorsbusiness.industryDetectorElectronScintillatorPhotoelectric effectKinetic energyOpticsbusinessInstrumentationNuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms
researchProduct

Position sensitive scintillator based detector improvements by means of an integrated front-end

2009

PESIC is an integrated front-end for multianode photomultiplier based nuclear imaging devices. Its architecture has been designed to improve position sensitive detectors behavior by equalizing its response over its whole area. Its preamplying stage introduces two main benefits: digitally programmable gain adjustment for every photomultiplier output, and isolation from other front-end electronics by means of current buffers. This last feature allows to use different types of photomultipliers and optimizes front-end deadtime, reducing impact position dependent output delay. PESIC also includes an indirect measurement of the depth of interaction of the gamma ray inside the scintillator crystal…

PhysicsNuclear and High Energy PhysicsPhotomultiplierbusiness.industryDetectorEqualization (audio)ScintillatorFront and back endsOpticsApplication-specific integrated circuitCalibrationElectronicsbusinessInstrumentationNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
researchProduct

A scintillator based time-of-flight hodoscope with a new type of emitter follower divider

2004

A high precision, time-of-flight hodoscope has been constructed to analyse the secondary pion beam at GSI, Darmstadt. The hodoscope comprises three scintillator planes with the individual scintillator rods read out by photomultipliers in both ends. A new active base of the emitter follower type has been developed for stabilization of voltages at the last dynodes of the photomultiplier. The time resolution of this system was found to be sigma less than or equal to 150 ps for counting rates up to 2 MHz.

PhysicsNuclear and High Energy PhysicsPhotomultiplierbusiness.industryPhysics::Instrumentation and Detectors25.80.Ls; 29.70.Eg; 25.75.Dw; 29.27.-tCommon collectorTime resolutionScintillatorRodTime of flightOpticsTime-of-flight measurementsHodoscopePhysics::Accelerator Physics[PHYS.PHYS.PHYS-INS-DET]Physics [physics]/Physics [physics]/Instrumentation and Detectors [physics.ins-det]businessNuclear ExperimentInstrumentationVoltage
researchProduct

Performance of the ALICE photon spectrometer PHOS

2003

Abstract We present in this paper the measured characteristics of a 64 lead–tungstate crystal array designed to detect high-energy photons and neutral mesons with the ALICE photon spectrometer PHOS. The array has been tested with electron and charged pion secondary beams delivered by the CERN PS and SPS synchrotrons. Photon energy and π 0 invariant mass resolutions are presented. The PHOS particle identification performance for data simulated with the AliRoot package is studied.

PhysicsNuclear and High Energy PhysicsPhotonLarge Hadron Collider25.75.Nq; 24.10.Lx; 25.75.-q; 29.40.VjMesonSpectrometerElectromagnetic calorimeters010308 nuclear & particles physicsPhysics::Instrumentation and DetectorsElectronPhoton energyHigh-energy gamma rays7. Clean energy01 natural sciencesParticle identificationQuark–gluon plasmaNuclear physicsPion0103 physical sciences[PHYS.HEXP]Physics [physics]/High Energy Physics - Experiment [hep-ex]PWO scintillators010306 general physicsNuclear ExperimentInstrumentation
researchProduct

Scintillators for photon detection at medium energies—a comparative study of BaF2, CeF3 and PbWO4

2002

Abstract In a comparative study, the performance of sub-arrays consisting of large CeF 3 and PbWO 4 crystals has been investigated with high-energy photons below 1 GeV. Energy and time resolutions are determined and compared with the corresponding values for BaF 2 based on the experience of operating the electromagnetic calorimeter Taps .

PhysicsNuclear and High Energy PhysicsPhotonOpticsElectromagnetic calorimeterElectromagnetic calorimetrybusiness.industryScintillatorbusinessInstrumentationPhoton detectionEnergy (signal processing)Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment