Search results for "SCOPE"

showing 10 items of 2420 documents

Optical magnification has no benefits on the detection of occlusal caries lesions in permanent molars using different visual scoring systems: An in v…

2020

Background Some studies have addressed the influence of optical magnification on the detection of caries lesions using a visual scoring system. However, there is a lack of research related to the use of the CAST and ADA-CCS visual scoring systems. In addition, the reliability and accuracy of ADA-CCS index in permanent teeth were not studied yet. So, the aim of this study was to evaluate, in vitro, the influence of different levels of optical magnification on the detection of occlusal caries lesions in permanent molars using three visual scoring systems. Material and Methods One occlusal site per tooth was analyzed in 120 extracted permanent molars. Two trained examiners inspected the teeth …

MolarCaries detectionMagnificationMagnification03 medical and health sciences0302 clinical medicinestomatognathic systemDentinmedicineVisual examination030212 general & internal medicineGeneral DentistryPermanent teethOrthodonticsReproducibilityEnamel paintbusiness.industryResearchOcclusal caries030206 dentistry:CIENCIAS MÉDICAS [UNESCO]Community and Preventive Dentistrystomatognathic diseasesmedicine.anatomical_structurevisual_artUNESCO::CIENCIAS MÉDICASDental cariesvisual_art.visual_art_mediumPermanent teethbusinessOperating microscopeJournal of Clinical and Experimental Dentistry
researchProduct

Evaluation of diagnostic accuracy and dimensional measurements by using CBCT in mandibular first molars

2015

Background: This study aimed to assess the diagnostic accuracy of cone beam computed tomography (CBCT) and quantitatively evaluate the morphology of mandibular first molars using CBCT. Material and Methods: Twenty-four double-rooted mandibular first molars were evaluated by NewTom VGi CBCT. The distance from the furcation and apex to the cementoenamel junction (CEJ), diameter and thickness of canal walls, the buccolingual (BL) to mesiodistal (MD) ratio (ΔD), prevalence of oval canals at different sections and taper of the canals were all determined. In order to assess the diagnostic accuracy of CBCT, distance from the furcation and apex to the CEJ and thickness of canal walls at the CEJ and…

MolarCone beam computed tomographyIntraclass correlationbusiness.industryResearchDentistryOdontología030206 dentistry:CIENCIAS MÉDICAS [UNESCO]Mandibular first molarCiencias de la saludOperative Dentistry and Endodontics030218 nuclear medicine & medical imagingApex (geometry)03 medical and health sciencesCementoenamel junction0302 clinical medicinestomatognathic systemStereo microscopeUNESCO::CIENCIAS MÉDICASMedicineCalipersbusinessGeneral Dentistry
researchProduct

Dentin bond strength and degree of conversion evaluation of experimental self-etch adhesive systems

2014

Background: The aim of this study was to investigate the effect of different concentrations of 10-methacryloyloxydecyl dihydrogen phosphate (10-MDP) monomer in one-step self-etch experimental adhesives on dentinal microshear bond strength (μSBS), their degree of conversion and bonded micro structure. Material and Methods: Composite resin cylinders (Clearfil AP-X) were bonded on human sound molar dentinal surfaces by using five experimental one-step self-etching adhesives (1-SEAs) containing 0% (E0), 5% (E5), 10% (E10), 15% (E15), 20% (E20) (by weight) 10-MDP monomer and Clearfil S3 Bond (CS3) as a control. After 24 hours, microshear bond strength was tested. The degree of conversion was als…

MolarMaterials scienceScanning electron microscopeBond strengthResearchComposite numberOdontologíaEsthetic Dentistry:CIENCIAS MÉDICAS [UNESCO]Ciencias de la saludchemistry.chemical_compoundmedicine.anatomical_structureMonomerchemistryUNESCO::CIENCIAS MÉDICASDentinmedicineAdhesiveComposite materialFourier transform infrared spectroscopyGeneral DentistryJournal of Clinical and Experimental Dentistry
researchProduct

Evaluation of marginal sealing quality of restorations with low shrinkage composite resins

2020

Background This study compared the quality of marginal sealing in the gingival wall of class II preparations of two low-shirinkage resins of the bulk fill type with a conventional resin isolated or associated with a glass ionomer cement (GIC). Material and methods 40 human molars were divided into 4 groups and 80 occlusal-mesial and occlusal-distal restorations were performed with the following materials: SureFil SDR flow, Filtek Bulk Fill Posterior, Z250 resins and Riva Light Cure GIC. 40 restorations were evaluated in Scanning Electron Microscopy (SEM) with Elemental Microanalysis Spectrometry (EDS) initially and the remainder after a period of 6 months of aging in a 37 ± 5°C oven. An ave…

MolarMaterials scienceScanning electron microscopeResearchResin composite0206 medical engineeringComposite numberGlass ionomer cementFiltek Bulk FillBulk fill030206 dentistry02 engineering and technology020601 biomedical engineering03 medical and health sciences0302 clinical medicinestomatognathic systemBiomaterials and Bioengineering in DentistryLow shrinkageComposite materialGeneral DentistryUNESCO:CIENCIAS MÉDICASJournal of Clinical and Experimental Dentistry
researchProduct

Effect of rotary cutting instruments on the resin-tooth interfacial ultra structure: An in vivo study

2013

Objectives: To evaluate the effect of cutting teeth with different types of burs at various speeds on surface topogra - phy of tooth surface and interfacial gap formation at resin-tooth interface. Material and Methods: The human molars were divided into seven groups: Diamond bur in airrotor (DA) & mi - cromotor (DM), crosscut carbide bur in airrotor (CCA) & micromotor (CCM), plain carbide bur in airrotor (CA) & micromotor (CM) and #600-grit silicon carbide paper (SiC). In five samples from each group Class II box-only cavities were restored. The occlusal surface of four teeth per group was flattened. Two out of four teeth were acid etched. Teeth were subjected for scanning electron microsco…

MolarMaterials scienceScanning electron microscopeSmear layerDentistryOdontologíaengineering.materialEndodonticsCarbidechemistry.chemical_compoundstomatognathic systemSilicon carbideComposite materialGeneral Dentistrybusiness.industryResearchTooth surfaceDiamond:CIENCIAS MÉDICAS [UNESCO]Ciencias de la saludAmorphous solidstomatognathic diseaseschemistryUNESCO::CIENCIAS MÉDICASengineeringbusinessJournal of Clinical and Experimental Dentistry
researchProduct

Evaluation of periimplant bone neoformation using different scanning electron microscope methods for measuring BIC. A dog study.

2012

Objetives: The aim of this study was to determine which of three methods for measuring BIC (bone-to-implant contact), using vestibular and lingual scanning electron microscopy (SEM) for different implant systems at 15, 30 and 90 days post-surgery was the most precise. An elemental analysis with SEM was used to evaluate neoformed bone composition for three implant systems at the same study times. Material and Methods: 36 implants were placed in eighteen Beagle dogs mandible about one year old and weighing approximately 12-13 kg in order to evaluate bone apposition to three different implant surfaces. It was used the third and fourth premolar and first molar distal sockets in both quadrants o…

MolarMaterials sciencebusiness.industryScanning electron microscopeMandibleH&E stainDentistryOdontología:CIENCIAS MÉDICAS [UNESCO]Ciencias de la saludApex (geometry)medicine.anatomical_structureTrichromeUNESCO::CIENCIAS MÉDICASPremolarmedicineImplantbusinessGeneral DentistryJournal of Clinical and Experimental Dentistry
researchProduct

Sealing effectiveness of fissure sealant bonded with universal adhesive systems on saliva-contaminated and noncontaminated enamel.

2017

Background The effectiveness of sealants is dependent upon their adhesion to enamel surface. The aim of the study was to evaluate the sealing ability of a pit and fissure sealant used with a universal adhesive (etch-and-rinse vs. self-etch modes) when the site is contaminated with saliva. Adhesive properties were evaluated as microleakage and scanning electron microscopic (SEM) characteristics. Material and methods A total of 72 mandibular third molars were randomly divided into 6 groups (n=12). Occlusal pits and fissures were sealed with an unfilled resin fissure sealant (FS) material with or without saliva contamination. The groups included: 1) phosphoric acid etching + FS (control), 2) p…

MolarSalivaMaterials scienceScanning electron microscopeDentistry02 engineering and technology03 medical and health scienceschemistry.chemical_compound0302 clinical medicinestomatognathic systemGeneral DentistryPhosphoric acidEnamel paintbusiness.industrySealantResearchfungitechnology industry and agriculture030206 dentistryContamination021001 nanoscience & nanotechnology:CIENCIAS MÉDICAS [UNESCO]Community and Preventive Dentistrychemistryvisual_artUNESCO::CIENCIAS MÉDICASvisual_art.visual_art_mediumAdhesive0210 nano-technologybusinessJournal of clinical and experimental dentistry
researchProduct

Durability of solvent-free one-step self-etch adhesive under simulated intrapulpal pressure

2015

Background: There are different solvents presented in simplified adhesives. Bond-1 SF has been developed, which contains neither water nor organic solvents, in order to eliminate technical issues in terms of evaporation of solvents and concerns for the durability of resin-dentin bond. Thus this study was conducted to evaluate the microtensile bond strength (μTBS) of solvent-free and ethanol-based one-step self-etch adhesives to dentin under simulated intrapulpal pressure (IPP). Material and Methods: Occlusal surfaces of human molars were prepared to expose mid-dentin depth. Bond-1SF Solvent-Free SE [SF] and Adper TM easy one [AE] adhesives were applied on dentin specimens. Resin composite b…

MolarUniversal testing machineMaterials scienceBond strengthResearchOne-StepOdontología:CIENCIAS MÉDICAS [UNESCO]DurabilityCiencias de la saludOperative Dentistry and Endodonticsmedicine.anatomical_structurestomatognathic systemStereo microscopeUNESCO::CIENCIAS MÉDICASDentinmedicineAdhesiveComposite materialGeneral Dentistry
researchProduct

On the origin of controlled anisotropic growth of monodisperse gold nanobipyramids

2021

We elucidate the crucial role of the cetyl trimethylammonium bromide (CTAB) surfactant in the anisotropic growth mechanism of gold nano-bipyramids, nano-objects with remarkable optical properties and high tunability. Atomistic molecular dynamics simulations predict different surface coverages of the CTAB (positively charged) heads and their (bromide) counterions as function of the gold exposed surfaces. High concentration of CTAB surfactant promotes formation of gold nanograins in solution that work as precursors for the smooth anisotropic growth of more elongated nano-bipyramidal objects. Nanobipyramids feature higher index facets with respect to nanorods, allowing higher CTAB coverages th…

Molecular dynamicMaterials scienceAbsorption spectroscopyScanning electron microscopeDispersity02 engineering and technologySurface active agents010402 general chemistry01 natural sciencesMolecular dynamicschemistry.chemical_compoundAbsorption spectroscopyPulmonary surfactantBromideGeneral Materials Sciencechemistry.chemical_classificationtechnology industry and agriculture021001 nanoscience & nanotechnologyOptical propertie0104 chemical scienceschemistryChemical engineeringAnisotropyNanorodGoldCounterion0210 nano-technologyScanning electron microscopyMicelleNanoscale
researchProduct

Flow-through pore characteristics of monolithic silicas and their impact on column performance in high-performance liquid chromatography

2008

Abstract In order to elucidate the role of the flow-through characteristics with regard to the column performance in high-performance liquid chromatography (HPLC) native and n -octadecyl bonded monolithic silica rods and columns, respectively of 100 mm length and 4.6 mm ID with mesopores in the range between 10 and 25 nm and macropores in the range between 0.7 and 6.0 μm were examined by mercury intrusion/extrusion, scanning electron microscopy, image analysis and permeability. The obtained data of the flow-through pore sizes and porosity values as well as surface-to-volume ratio of the stationary phase skeleton enabled to predict their influence to the chromatographic separation efficiency…

Monolithic HPLC columnChromatographyChemistryScanning electron microscopeSilica gelOrganic ChemistryAnalytical chemistryGeneral MedicinePorosimetryReversed-phase chromatographySilicon DioxideBiochemistryAnalytical ChemistrySeparation processchemistry.chemical_compoundMicroscopy Electron ScanningPorosityMesoporous materialPorosityChromatography High Pressure LiquidJournal of Chromatography A
researchProduct